[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-198111-105":53,"doc-detail-198111-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","wireless-pg-detector-and-device-model-list-key-function-definitions","Wireless PG - Detector and Device Model List - Key Function Definitions","","Wireless PG device lineup and configuration guidance focusing on detector types, model identifiers, and keypad/programming behavior. Includes a catalog of wireless PG smoke, CO, PIR, dual-tech, curtain, mirror, outdoor, glass break, shock, flood, and temperature detectors, plus supporting components like keys, sirens, repeaters, and door/window contacts. Provides language key mappings, keypad function key defaults (arm/stay/away/chime), icon meanings, device programming options, wireless zone/siren/keypad sub-sections, and jamming/supervision reporting settings.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":11,"@type":70,"position":76},"https://docshare.wps.com/template/presentations/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/wireless-pg-detector-and-device-model-list-key-function-definitions/198111/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/wireless-pg-detector-and-device-model-list-key-function-definitions/198111.png","ImageObject",442,249,{"name":88,"@type":89},"Rizky","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-11","2026-09-03",true,{"@type":98,"interactionType":99,"userInteractionCount":76},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"Which Wireless PG detector categories and model numbers are listed?","Question",{"text":108,"@type":109},"The list covers smoke/heat, CO, PIR motion, PIR with camera, curtain, dual tech, mirror motion, outdoor motion, glass break, shock, flood, temperature (indoor), and door/window-related devices, each with specific model codes.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"What do keypad default function keys represent (e.g., Stay Arm, Away Arm)?",{"text":113,"@type":109},"The configuration table defines Key 1–5 defaults such as Stay Arm, Away Arm, Chime ON/OFF, and Command Output, along with valid range and function behavior.",{"name":115,"@type":106,"acceptedAnswer":116},"How is RF jamming detection configured and when is it required?",{"text":117,"@type":109},"A setting enables/disables jamming detection and reporting, with a note that UL/ULC listed installations must have it enabled; options specify continuous or accumulated jamming duration thresholds.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},198111,1790142049,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":8,"category_name":11,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":135,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":37,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":20},962085564807,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","| Wireless PG smoke detector | PGx926UL |\n| --- | --- |\n| Wireless PG smoke and heat detector | PGx916UL |\n| Wireless PG CO detector | PGx913 |\n| Wireless PG PIR motion detector | PGx904(P)UL |\n| Wireless PG PIR + camera motion detector | PGx934(P)UL |\n| Wireless PG curtain motion detector | PGx924UL |\n| Wireless PG dual tech motion detector | PGx984(P) |\n| Wireless PG mirror motion detector | PGx974(P)UL |\n| Wireless PG outdoor motion detector | PGx994UL |\n| Wireless PG glass break detector | PGx912 |\n| Wireless PG shock detector | PGx935UL |\n| Wireless PG flood detector | PGx985UL |\n| Wireless PG temperature detector (indoor) | PGx905UL |\n| Outdoor temperature probe (requires PGx905) | PGTEMP-PROBE |\n| Wireless PG key | PGx939UL |\n| Wireless PG key | PGx929UL |\n| Wireless PG panic key | PGx938UL |\n| Wireless PG 2-button key | PGx949UL |\n| Wireless PG indoor siren | PGx901UL |\n| Wireless PG outdoor siren | PGx911UL |\n| Wireless PG repeater | PGx920UL |\n| Wireless PG door/window contact | PGx975UL |\n| Wireless PG door/window contact w/AUX | PGx945UL |\n\n| 01 = English (default) | 10 = German | 20 = Romanian |\n| --- | --- | --- |\n|  | 11 = Swedish | 21 = Russian |\n| 02 = Spanish | 12 = Norwegian | 22 = Bulgarian |\n| 03 = Portuguese | 13 = Danish | 23 = Latvian |\n| 04 = French | 14 = Hebrew | 24 = Lithuanian |\n| 05 = Italian | 15 = Greek | 25 = Ukrainian |\n| 06 = Dutch | 16 = Turkish | 26 = Slovak |\n| 07 = Polish | 17 = Future Use | 27 = Serbian |\n| 08 = Czech | 18 = Croatian | 28 = Estonian |\n| 09 = Finnish | 19 = Hungarian | 29 = Slovenian |\n\n\n| [1] -A, B, C, 1 | [5] -M, N, O, 5 | [9] -Y, Z, 9, 0 |\n| --- | --- | --- |\n| [2] -D, E, F, 2 | [6] -P, Q, R, 6 | [0] -Space |\n| [3] -G, H, I, 3 | [7] -S, T, U, 7 | [*] -Select |\n| [4] -J, K, L, 4 | [8] -V, W, X, 8 | [\\#] -Escape |\n\n\n|  | Function Key | Button | Valid Range | Default | Function |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| [001] | Key 1 | | 00–68 | 03 | Stay Arm | |_____|_____| |\n| [002] | Key 2 | | 00–68 | 04 | Away Arm | |_____|_____| |\n| [003] | Key 3 | | 00–68 | 06 | Chime ON/OFF | |_____|_____| |\n| [004] | Key 4 | | 00–68 | 22 | Command Output 2 | |_____|_____| |\n| [005] | Key 5 | | 00–68 | 16 | Quick Exit | |_____|_____| |\n\n\n|  | \u003Cbr>|  |  14\u003Cbr>\u003Cbr>\u003Cbr>|\n| --- | --- | --- | --- |\n| 1 | Memory – Indicates that alarms are in memory. | 10 | Chime – Turns on when Door Chime is enabled and off when Door Chime is disabled. |\n| 2 | Fire – Indicates that fire alarms are in memory. | 11 | Away – Indicates that the panel is armed in away mode. |\n| 3,4,5 | Clock Digits – These digits indicate the hour and minutes when the local clock is active, and also identify the zone when the OPEN or ALARM icons are active. These digits scroll one zone per second from the lowest zone number to the highest when scrolling through zones . | 12 | Stay – Indicates that the panel is armed in stay mode. |\n|  |  | 13 | Night – Indicates that the panel is armed in night mode. |\n| 6 | 1 to 8 – These numbers display toggles or digits in binary while they are needed. | 14 | Ready Light (green)–If the Ready light is on, the system is ready for arming. |\n| 7 | Bypass – Indicates that there are zones automatically or manually bypassed. | 15 | Armed Light (red)–If the Armed light is on, the system has been armed successfully. |\n| 8 | Open – When zones are opened, this icon will turn on and the open zones are displayed. | 16 | System Trouble – Indicates that a system trouble is active. |\n| 9 | Program – If the system is in Installer’s or User’s Programming, or the keypad is busy, this icon flashes . If an access code is required while accessing star menus, this LED is on steadily to indicate that the code is required. | 17 | AC – Indicates that AC is\u003Cbr>present at the main panel. |\n\n\n| Device Type | Programming Options |\n| --- | --- |\n| Zone | (01) Zone type\u003Cbr>(02) Partition assignment\u003Cbr>(03) Zone label |\n| Wireless key | (01) Partition assignment\u003Cbr>(02) User label |\n|  |  |\n| Siren | (01) Partiti","cbCaig5brCoSJqSt","https://ap.wps.com/l/cbCaig5brCoSJqSt","pdf",1322087,8,"English","# Wireless PG device models\n## Detector types and model identifiers\n## Keys, sirens, repeater and door/window contacts\n# Keypad and control mappings\n## Language selection codes\n## Key function ranges and defaults\n## Icon/function descriptions and arming modes\n# Programming configuration options\n## Device type programming options\n## Wireless sub-sections\n## Jamming detection and reporting\n## Wireless supervisory and RF jam behavior\n## Supervision timing and fire supervision\n## Visual verification setting","[{\"question\":\"Which Wireless PG detector categories and model numbers are listed?\",\"answer\":\"The list covers smoke/heat, CO, PIR motion, PIR with camera, curtain, dual tech, mirror motion, outdoor motion, glass break, shock, flood, temperature (indoor), and door/window-related devices, each with specific model codes.\"},{\"question\":\"What do keypad default function keys represent (e.g., Stay Arm, Away Arm)?\",\"answer\":\"The configuration table defines Key 1–5 defaults such as Stay Arm, Away Arm, Chime ON/OFF, and Command Output, along with valid range and function behavior.\"},{\"question\":\"How is RF jamming detection configured and when is it required?\",\"answer\":\"A setting enables/disables jamming detection and reporting, with a note that UL/ULC listed installations must have it enabled; options specify continuous or accumulated jamming duration thresholds.\"}]","Wireless PG - Detector and Device Model List - Key Function Definitions | PDF",1788474678]