[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-160166-105":53,"doc-detail-160166-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","watermark-technical-specification-template-writing-and-formatting-guide","WATERMARK TECHNICAL SPECIFICATION TEMPLATE - Writing and Formatting Guide","","WATERMARK TECHNICAL SPECIFICATION TEMPLATE提供编写与排版WaterMark产品规范的要求与指导，适用于给排水产品评估，并可用于除WMTS以外的其他产品规范情境。模板明确采用Microsoft Word 2013的版式要素，并要求WMTS内的图片与表格使用alt文本以提升可访问性。文档给出规范正文应包含的条款顺序、VOID标注规则，以及附录A与附录B的合规演示与产品性能测试编写要点与表格填写逻辑。",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":36,"@type":70,"position":76},"https://docshare.wps.com/template/forms/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/watermark-technical-specification-template-writing-and-formatting-guide/160166/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/watermark-technical-specification-template-writing-and-formatting-guide/160166.png","ImageObject",442,249,{"name":88,"@type":89},"Connor ","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/vnd.openxmlformats-officedocument.wordprocessingml.document","2026-09-21","2026-08-30",true,{"@type":98,"interactionType":99,"userInteractionCount":73},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"WMTS（WaterMark Technical Specification）需要包含哪些主要条款？","Question",{"text":108,"@type":109},"WMTS应按指定顺序包含Scope、Application、Referenced documents、Definitions、Materials、Marking、Packaging、Design、Performance criteria and test methods、Test sequence and test sample plan、Product documentation，并附上附录A与附录B。","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"当规范不需要使用某个条款时，应该如何标注？",{"text":113,"@type":109},"当没有要求使用某一条款时，需在对应标题处标注“VOID”，例如“7. Packaging (VOID)”。",{"name":115,"@type":106,"acceptedAnswer":116},"附录A与附录B各负责什么内容？",{"text":117,"@type":109},"附录A给出制造商用于证明符合本规范的合规演示方法，并要求填写表A1至A4（如适用）；附录B描述产品性能测试方法，必要时为每个单独测试方法或测试装置规范单独成附录。","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},160166,1788051140,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":35,"category_name":36,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":73,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":35,"language":135,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":136,"faqs":137,"seo_title":138,"seo_description":61,"update_tm":125,"read_time":139},687207022233,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","WATERMARK TECHNICAL SPECIFICATION TEMPLATE\nThis document includes the requirements and guidance for writing and formatting a WaterMark Product Specification for the evaluation of plumbing and drainage products, and outlines the typical requirements for these products.\nThis template is to be used to create a WaterMark Technical Specification (WMTS). This template may also be used for product specifications other than WMTS, such as Australian Standards. The template includes set margins, headers and footers, line spacing, and heading styles. The template has been created in Microsoft Word 2013.\nNote: When published by the ABCB as a WMTS, the ABCB will attach standard covers, a title page, disclaimer, and a preface for this document. If published by a third party standards writing body as a product specification other than a WMTS, that body will format the document according to its publishing styles.\nAll images and tables within the WMTS are to use alt text. Providing alt text allows all users to access the same information, whether they can see the image or not.\nThe following table describes how to use the styles within this template.\nTEMPLATE STYLES\nREQUIREMENTS FOR SPECIFICATIONS\nGeneral\nA WMTS shall include the following clauses and appendices in the order shown:\n1 \tScope\n2 \tApplication\n3 \tReferenced documents\n4 \tDefinitions\n5 \tMaterials\n6 \tMarking\n7 \tPackaging\n8 \tDesign\n9 \tPerformance criteria and test methods\n10 \tTest sequence and test sample plan\n11 \tProduct documentation\nMeans for demonstrating compliance with this specification (Appendix A)\nProduct performance test methods (Appendix B)\nWhere there is no requirement to use one of the above clauses in the specification, the heading shall be annotated with the word ‘VOID’ e.g. 7. Packaging (VOID).\nThe specification should include, but is not limited to, the requirements listed. The requirements listed should be used as guidance.\nWhere applicable, reference should be made to the relevant Australian Standard, WaterMark Product Specification or an approved (endorsed) international Standard, rather than reproducing content from such documents.\n\u000f\nGUIDANCE FOR DRAFTING APPENDICES\nMeans for demonstrating compliance with this specification (Appendix A)\nAn ‘Appendix A’ as set out in this document shall be included (see Appendix A).\nThis Appendix sets out the means by which compliance with the specification can be demonstrated by a manufacturer for the purpose of product certification.\nTables A1, A2, A3 and A4 (where applicable) shall be completed, taking into account the relevant requirements for the product, prior to the submission of the specification to the ABCB Office as follows:\na) \tTable A1 shall specify tests by one of the following options:\n1 \tWhere the specification is a modification of an existing Australian Standard, Table A1 in the relevant Standard, as modified by the clauses in the specification, shall apply.\n2 \tWhere the specification is developed for new products not based on an existing standard, Table A1 shall include type tests to evaluate the product against each clause of the specification.\nb) \tTable A2 shall specify tests by one of the following options:\n1 \tWhere the specification modifies an existing Australian Standard, Table A2 in the relevant standard, as modified by the clauses in the specification, shall apply.\n2 \tWhere the specification is developed for new products not based on existing standards, Table A2 shall include batch release tests to evaluate the consistency of production in accordance with the sampling plan and appropriate to the risks as identified in the risk assessment and 100% compliance with critical performance criteria as appropriate.\nc) \tTable A3 shall include annual inspection requirements to evaluate the product against each relevant clause of the specification.\nd)\tTable A4 shall include re-evaluation tests to evaluate the product against each clause of the specification.\nProduct performance test methods (Appendix B)\nProduct testing ","cbCaiuOld0setpSS","https://ap.wps.com/l/cbCaiuOld0setpSS","docx",81292,"English","# Requirements for specifications\n## General\n# Guidance for drafting appendices\n## Means for demonstrating compliance with this specification (Appendix A)\n## Product performance test methods (Appendix B)\n# Scope\n# Application\n# Referenced documents\n# Definitions\n# Materials\n# Marking\n# Packaging\n# Design\n# Performance criteria and test methods\n# Test sequence and test sample plan\n# Product documentation","[{\"question\":\"WMTS（WaterMark Technical Specification）需要包含哪些主要条款？\",\"answer\":\"WMTS应按指定顺序包含Scope、Application、Referenced documents、Definitions、Materials、Marking、Packaging、Design、Performance criteria and test methods、Test sequence and test sample plan、Product documentation，并附上附录A与附录B。\"},{\"question\":\"当规范不需要使用某个条款时，应该如何标注？\",\"answer\":\"当没有要求使用某一条款时，需在对应标题处标注“VOID”，例如“7. Packaging (VOID)”。\"},{\"question\":\"附录A与附录B各负责什么内容？\",\"answer\":\"附录A给出制造商用于证明符合本规范的合规演示方法，并要求填写表A1至A4（如适用）；附录B描述产品性能测试方法，必要时为每个单独测试方法或测试装置规范单独成附录。\"}]","WATERMARK TECHNICAL SPECIFICATION TEMPLATE - Writing and Formatting Guide | DOCX",6]