[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-252991-105":53,"doc-detail-252991-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","waste-water-discharge-licence-site-visit-report-2022","Waste Water Discharge Licence - Site Visit Report - 2022","","Waste Water Discharge Licence site visit report template for 2022, designed to document a random day assessment of a facility’s operation and environmental performance. Captures key administrative details (agglomeration, licensee, weather, personnel, licence register number) and structured checks across flow measurement, composite sampling, control and monitoring systems, discharge conditions, and receiving-water impacts. Includes fields for discharge sampling evidence, observations, and photographic/video documentation to support compliance review.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":36,"@type":70,"position":76},"https://docshare.wps.com/template/forms/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/waste-water-discharge-licence-site-visit-report-2022/252991/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/waste-water-discharge-licence-site-visit-report-2022/252991.png","ImageObject",442,249,{"name":88,"@type":89},"Sarah ","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-22","2026-09-13",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",7,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What purpose does the site visit report serve for 2022 waste water discharges?","Question",{"text":109,"@type":110},"It records a random sample site visit to assess facility operation and environmental performance for licence compliance review.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"Which sampling and measurement systems are checked during the visit?",{"text":114,"@type":110},"The template checks flow meter equipment, continuous flow recorder availability, and the availability/cleanliness of 24hr composite sampler bottles, plus grab-sample and split-sample steps at the discharge.",{"name":116,"@type":107,"acceptedAnswer":117},"What discharge and receiving-water observations are required?",{"text":118,"@type":110},"It captures evidence such as gross solids or litter, whether the monitoring point is clearly labelled, the appearance of discharge samples, and any impairment or interference in the receiving water tied to the discharge.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},252991,1790088984,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":35,"category_name":36,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":76,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":9},962085320529,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Waste Water Discharge Licence-Site Visit Report-2022  \n| This site visit is a random sample on a particular day of a facility’s operation and environmental performance. Lack of reporting of an area or issue should not be construed to mean that this area is fully satisfactory. |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| NAME OF AGGLOMERATION: | Date of Site Visit: |  |  |  |\n| LICENSEE: Irish Water | Name(s) of EPA Personnel: |  |  |  |\n| LICENSE REGISTER NUMBER: | Name(s) of Licensee Personnel: |  |  |  |\n| WEATHER CONDITIONS: | Time In: |  |  | Time Out: |\n| WEATHER CONDITIONS OVER 24HRS: |  |  |  |  |\n|  | Yes | No | N/A | Comment |\n| 1. Flow Meter |  |  |  |  |\n| 1.1 Is there a continuous flow meter in place at the primary discharge? |  |  |  |  |\n| 1.2 Is a continuous flow recorder in place? |  |  |  |  |\n| 2. Composite Sampler |  |  |  |  |\n| 2.1 Is there a 24hr composite sampler available for compliance\u003Cbr>monitoring at the primary discharge? |  |  |  |  |\n| 2.2 Are sample bottles in the composite sampler clean? |  |  |  |  |\n| 2.3 Was there a sample available for the previous 24 hours? |  |  |  |  |\n\n\n|  | Yes | No | N/A | Comment |\n| --- | --- | --- | --- | --- |\n| 3. Control & Monitoring |  |  |  |  |\n| 3.1 Is there an inlet screen at the plant? |  |  |  |  |\n| 3.2 Does the inlet screen appear to be working satisfactorily? |  |  |  |  |\n| 3.3 If there is a clarifier on site, is there evidence in the clarifier of any solids carryover into the final effluent? |  |  |  |  |\n| 3.4 Is there a Dissolved Oxygen meter at the plant? |  |  |  |  |\n| 3.5 Is the SWO at the WWTP discharging on the day of the site visit? |  |  |  |  |\n| 3.6 Is there chemical dosing for P removal at the WWTP? |  |  |  |  |\n\n\n| NAME OF AGGLOMERATION: |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| NAME OF RECEIVING WATER: |  |  |  | GIS CO-ORDINATES OF\u003Cbr>DISCHARGE: |\n| PRIMARY DISCHARGE POINT CODE: |  |  |  | PHOTOGRAPHS TAKEN:\u003Cbr>VIDEO TAKEN: |\n|  |  |  |  |  |\n| 4.0 DISCHARGE |  |  |  |  |\n|  | Yes |  | No | COMMENTS |\n| 4.1 Is the primary discharge monitoring point clearly labeled? |  |  |  |  |\n| 4.2 Was there evidence of gross solids or litter in the discharge? |  |  |  |  |\n| 4.3 Was a grab sample taken? |  |  |  |  |\n| 4.4 Was a split sample offered to the licensee? |  |  |  |  |\n| 4.5 Time that sample was taken: |  |  |  |  |\n| 4.6 What is the appearance of the discharge sample? |  |  |  |  |\n|  |  |  |  |  |\n| 5.0 RECEIVING WATER |  |  |  |  |\n|  | Yes | No | N/A | COMMENTS |\n| 5.1 Was there evidence of gross solids or litter or any impact in the receiving water associated with the discharge, resulting in an impairment of, or an interference with, amenities or the environment? |  |  |  |  |\n| 6.0 Primary Discharge Observations |  |  |  |  |\n| 6.1 Has the licensee's representative been informed of the observations made while on site? (Yes/No) |  |  |  |  |\n| 6.2 Other Observations/Comments? |  |  |  |  |\n| 7.0 Site Visit Observations and Comments |  |  |  |  |\n|  |  |  |  |  |\n\n\n| NAME OF AGGLOMERATION: |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| NAME OF RECEIVING WATER: |  |  |  | GIS CO-ORDINATES OF\u003Cbr>DISCHARGE: |\n| |  |  |  | PHOTOGRAPHS TAKEN:\u003Cbr>VIDEO TAKEN: |\n| TIME IN:\u003Cbr>TIME OUT: |  |  |  | WEATHER: |\n|  |  |  |  | WEATHER CONDITIONS\u003Cbr>OVER 24HRS: |\n| 8.0 CONTROL & MONITORING OF WASTE WATER DISCHARGES |  |  |  |  |\n| 8.1 Flow Meter | Yes | No | N/A | COMMENTS |\n| 8.1.1 Is there a continuous flow meter in place at the secondary discharge? |  |  |  |  |\n| 8.1.2 Is there a continuous flow recorder in place? |  |  |  |  |\n| 8.2 Composite Sampler |  |  |  |  |\n| 8.2.1 Is there a 24hr composite sampler available for\u003Cbr>compliance monitoring at the secondary discharge? |  |  |  |  |\n| 8.3 DISCHARGE |  |  |  |  |\n|  | Yes |  | No | COMMENTS |\n| 8.3.1. Is the discharge monitoring point clearly labeled? |  |  |  |  |\n| 8.3.2. Was there evidence of gross solids or litter in the discharge? |  |  |  |  |\n| 8.3.3. Was a grab sample take","cbCainRB24YfuEeC","https://ap.wps.com/l/cbCainRB24YfuEeC","pdf",186767,"English","# NAME OF AGGLOMERATION\n## LICENSEE & EPA Personnel\n## WEATHER CONDITIONS\n# Flow Meter\n## Continuous flow meter/recorder (primary)\n# Composite Sampler\n## 24hr composite sampler (primary)\n# Control & Monitoring\n## Inlet screen, dissolved oxygen, SWO, chemical dosing\n# DISCHARGE\n## Primary discharge monitoring and sampling\n# RECEIVING WATER\n## Receiving-water impacts\n# Primary Discharge Observations\n## Informed status & other comments\n# CONTROL & MONITORING OF WASTE WATER DISCHARGES\n## Secondary discharge controls\n# Secondary Discharge Observations\n## Observations & other comments","[{\"question\":\"What purpose does the site visit report serve for 2022 waste water discharges?\",\"answer\":\"It records a random sample site visit to assess facility operation and environmental performance for licence compliance review.\"},{\"question\":\"Which sampling and measurement systems are checked during the visit?\",\"answer\":\"The template checks flow meter equipment, continuous flow recorder availability, and the availability/cleanliness of 24hr composite sampler bottles, plus grab-sample and split-sample steps at the discharge.\"},{\"question\":\"What discharge and receiving-water observations are required?\",\"answer\":\"It captures evidence such as gross solids or litter, whether the monitoring point is clearly labelled, the appearance of discharge samples, and any impairment or interference in the receiving water tied to the discharge.\"}]","Waste Water Discharge Licence - Site Visit Report - 2022 | PDF",1789263691]