[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-detail-245553-en":53,"doc-seo-245553-105":74},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":5,"data":54},{"doc_id":55,"user_id":56,"nickname":57,"user_avatar":58,"doc_module":9,"category_id":8,"category_name":11,"doc_title":59,"doc_description":60,"doc_content":61,"file_id":62,"file_url":63,"file_type":64,"file_size":65,"view_count":66,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":42,"language":67,"language_code":68,"site_id":69,"html_lang":68,"table_of_contents":70,"faqs":71,"seo_title":72,"seo_description":60,"update_tm":73,"read_time":8},245553,1374391974468,"Eden","https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Wansley AP-1 CQA Plan - Plant Wansley Ash Pond 1 Closure - Revision 1 - November 2025","Construction Quality Assurance (CQA) Plan defines quality requirements and verification processes for Plant Wansley Ash Pond 1 (AP-1) closure in Heard and Carroll Counties, Georgia. Revision 1 dated November 2025 outlines the CQA/CQC approach, including conformance and performance testing methods and how evidence is produced and managed. The plan establishes CQA and CQC personnel roles, documentation controls for daily records and reports, certification reporting expectations, and field activities covering earthwork, CCR removal verification, and geotextile transportation, sampling, testing, and placement.","CONSTRUCTION QUALITY ASSURANCE  \nPLAN  \nPLANT WANSLEY ASH POND 1 (AP-1) CLOSURE HEARD AND CARROLL COUNTIES, GEORGIA  \nFOR  \nREVISION 1  \nNOVEMBER 2025  \nDigitally signed by Jeremy Gasser Date: 2025.11.10 16:05:32-06'00'  \nTABLE OF CONTENTS  \n1. INTRODUCTION ................................................................................................................ 1  \n1.1 OVERVIEW .............................................................................................................. 1  \n1.2 PROJECT DESCRIPTION........................................................................................... 1  \n1.3 CQA PLAN SCOPE ................................................................................................... 2  \n2. CQA PLAN DEFINITIONS AND CQA/CQC APPROACH ....................................................... 2  \n2.1 CONSTRUCTION QUALITY ASSURANCE AND CONSTRUCTION QUALITY CONTROL 2  \n2.2 CONFORMANCE TESTING AND PERFORMANCE TESTING...................................... 3  \n3. PERSONNEL ...................................................................................................................... 3  \n3.1 CQA CONSULTANT ................................................................................................. 3  \n3.1.1 Definition ................................................................................................. 3  \n3.1.2 Qualifications ........................................................................................... 3  \n3.1.3 Responsibilities ........................................................................................ 4  \n3.2 CQA GEOSYNTHETICS LABORATORY ...................................................................... 7  \n3.2.1 Definition ................................................................................................. 7  \n3.2.2 Qualifications ........................................................................................... 7  \n3.3 CQC Personnel ....................................................................................................... 7  \n3.3.1 Definition ................................................................................................. 7  \n3.3.2 Qualifications ........................................................................................... 8  \n3.4 EARTHWORK LABORATORY ................................................................................... 8  \n3.4.1 Definition ................................................................................................. 8  \n3.4.2 Qualifications ........................................................................................... 8  \n3.5 DESIGN ENGINEER.................................................................................................. 8  \n3.6 SURVEYOR .............................................................................................................. 9  \n3.7 CONSTRUCTION MANAGER ................................................................................... 9  \n3.8 Contractor .............................................................................................................. 9  \n3.9 GEOSYNTHETICS MANUFACTURERS AND INSTALLERS ........................................ 10  \n4. DOCUMENTATION ......................................................................................................... 10  \n4.1 OVERVIEW ............................................................................................................ 10  \n4.2 DAILY RECORD KEEPING....................................................................................... 11  \n4.2.1 Daily Field Reports ................................................................................. 11  \n4.2.2 Monitoring Logs, Test Data Sheets, and Photographs .......................... 11  \n4.2.3 Non-conformance and Corrective Measures Reporting ....................... 12  \n4.3 CQA CERTIFICATION REPORT ..................................................","cbCaif7BjBCrIGou","https://ap.wps.com/l/cbCaif7BjBCrIGou","pdf",639537,7,"English","en",105,"# Introduction\n## Overview\n## Project Description\n## CQA Plan Scope\n# CQA Plan Definitions and CQA/CQC Approach\n## Construction Quality Assurance and Construction Quality Control\n## Conformance Testing and Performance Testing\n# Personnel\n## CQA Consultant\n## CQA Geosynthetics Laboratory\n## CQC Personnel\n## Earthwork Laboratory\n## Design Engineer\n## Surveyor\n## Construction Manager\n## Contractor\n## Geosynthetics Manufacturers and Installers\n# Documentation\n## Overview\n## Daily Record Keeping\n## Daily Field Reports\n## Monitoring Logs, Test Data Sheets, and Photographs\n## Non-conformance and Corrective Measures Reporting\n## CQA Certification Report\n# Earthwork\n## Introduction\n## Record Drawings and As-Built Surveys\n## Conformance Observations\n## Construction Monitoring\n# CCR Removal\n## Introduction\n## Excavation Verification Protocol\n# Geotextiles\n## Introduction\n## Transportation, Handling, and Storage\n## Manufacturer QC (MQC) Testing and Conformance (CQA) Testing","[{\"question\":\"What is the purpose of the Wansley AP-1 CQA plan for the ash pond closure?\",\"answer\":\"The plan establishes the construction quality assurance requirements and verification processes for Plant Wansley Ash Pond 1 (AP-1) closure, including how conformance evidence is collected and reported.\"},{\"question\":\"What testing approaches are included in the CQA/CQC section?\",\"answer\":\"The plan covers both conformance testing and performance testing as part of the CQA/CQC approach, including how results are evaluated through sampling and testing requirements.\"},{\"question\":\"How does the plan handle documentation and non-conformance during construction?\",\"answer\":\"The documentation section specifies daily record keeping via daily field reports and supporting logs, and it defines how non-conformance and corrective measures reporting must be completed and tracked.\"}]","Wansley AP-1 CQA Plan - Plant Wansley Ash Pond 1 Closure - Revision 1 - November 2025 | PDF",1789229403,{"code":4,"msg":75,"data":76},"ok",{"site_id":69,"language":68,"slug":77,"title":59,"keywords":78,"description":60,"schema_data":79,"social_meta":135,"head_meta":137,"extra_data":139,"updated_unix":140},"wansley-ap-1-cqa-plan-plant-wansley-ash-pond-1-closure-revision-1-november-2025","",{"@graph":80,"@context":134},[81,97,117],{"@type":82,"itemListElement":83},"BreadcrumbList",[84,88,91,94],{"item":85,"name":86,"@type":87,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":89,"name":10,"@type":87,"position":90},"https://docshare.wps.com/template/",2,{"item":92,"name":11,"@type":87,"position":93},"https://docshare.wps.com/template/presentations/",3,{"item":95,"name":59,"@type":87,"position":96},"https://docshare.wps.com/template/wansley-ap-1-cqa-plan-plant-wansley-ash-pond-1-closure-revision-1-november-2025/245553/",4,{"url":95,"name":59,"@type":98,"image":99,"author":104,"headline":59,"publisher":106,"fileFormat":109,"inLanguage":68,"description":60,"dateModified":110,"datePublished":111,"encodingFormat":109,"isAccessibleForFree":112,"interactionStatistic":113},"DigitalDocument",{"url":100,"@type":101,"width":102,"height":103},"https://docshare.wps.com/thumbnails/wansley-ap-1-cqa-plan-plant-wansley-ash-pond-1-closure-revision-1-november-2025/245553.png","ImageObject",442,249,{"name":57,"@type":105},"Person",{"url":85,"name":107,"@type":108},"DocShare","Organization","application/pdf","2026-10-19","2026-09-12",true,{"@type":114,"interactionType":115,"userInteractionCount":66},"InteractionCounter",{"@type":116},"ViewAction",{"@type":118,"mainEntity":119},"FAQPage",[120,126,130],{"name":121,"@type":122,"acceptedAnswer":123},"What is the purpose of the Wansley AP-1 CQA plan for the ash pond closure?","Question",{"text":124,"@type":125},"The plan establishes the construction quality assurance requirements and verification processes for Plant Wansley Ash Pond 1 (AP-1) closure, including how conformance evidence is collected and reported.","Answer",{"name":127,"@type":122,"acceptedAnswer":128},"What testing approaches are included in the CQA/CQC section?",{"text":129,"@type":125},"The plan covers both conformance testing and performance testing as part of the CQA/CQC approach, including how results are evaluated through sampling and testing requirements.",{"name":131,"@type":122,"acceptedAnswer":132},"How does the plan handle documentation and non-conformance during construction?",{"text":133,"@type":125},"The documentation section specifies daily record keeping via daily field reports and supporting logs, and it defines how non-conformance and corrective measures reporting must be completed and tracked.","https://schema.org",{"og:url":95,"og:type":136,"og:title":59,"og:site_name":107,"og:description":60},"article",{"robots":138,"canonical":95},"index,follow",{"doc_id":55,"site_id":69},1791128703]