[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-571321-105":3,"detail-sidebar-cat-1-en-105":81,"doc-detail-571321-en":127},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","viscosity-conversion-chart","Viscosity Conversion Chart","","This technical document provides a comprehensive reference for comparing various viscosity measurement standards used in industrial and automotive lubrication applications. It features a detailed conversion chart that correlates Kinematic Viscosity (measured in cSt at 40°C and 100°C) with Saybolt Viscosity (measured in SUS at 100°F and 210°F). Additionally, it maps these values to standardized industry grading systems, including AGMA ISO VG grades, SAE Motor Oil grades, and SAE Gear Oil grades. Designed for engineers, mechanics, and industrial maintenance professionals, the chart enables accurate cross-referencing of lubricant specifications to ensure the correct fluid selection for equipment performance. The data is structured to allow quick identification of equivalent viscosity ratings across different testing protocols, facilitating seamless maintenance and lubrication management. By aligning multiple international standards within a single resource, it serves as a vital diagnostic and reference tool for fluid analysis and technical procurement in heavy machinery, automotive maintenance, and industrial lubrication systems.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/general/","General",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/viscosity-conversion-chart/571321/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/viscosity-conversion-chart/571321.png","ImageObject",442,249,{"name":42,"@type":43},"RuangKosong","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-24","2026-10-13",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",10,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the primary purpose of this chart?","Question",{"text":63,"@type":64},"The chart serves as a reference for cross-referencing lubricant viscosities across different standards, including Kinematic Viscosity (cSt), Saybolt Viscosity (SUS), AGMA ISO VG grades, and SAE motor/gear oil grades.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which temperature points are used for Kinematic Viscosity measurement in this document?",{"text":68,"@type":64},"The document provides Kinematic Viscosity values measured at both 40°C and 100°C.",{"name":70,"@type":61,"acceptedAnswer":71},"How are Saybolt Viscosities represented in this chart?",{"text":72,"@type":64},"Saybolt Viscosities are represented as SUS (Saybolt Universal Seconds) values, specifically categorized for measurements taken at 100°F and 210°F.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},571321,1792082804,{"code":4,"msg":82,"data":83},"success",[84,89,94,99,104,109,114,119,124],{"id":85,"doc_module":22,"doc_module_name":25,"category_name":86,"show_sort_weight":87,"slug":88},11,"Presentations",90,"presentations",{"id":90,"doc_module":22,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},12,"Resumes",80,"resumes",{"id":95,"doc_module":22,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},14,"Invoices",70,"invoices",{"id":100,"doc_module":22,"doc_module_name":25,"category_name":101,"show_sort_weight":102,"slug":103},15,"Posters",60,"posters",{"id":105,"doc_module":22,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},16,"Social Media",50,"social-media",{"id":110,"doc_module":22,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},17,"Forms",40,"forms",{"id":115,"doc_module":22,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},18,"Letters",30,"letters",{"id":120,"doc_module":22,"doc_module_name":25,"category_name":121,"show_sort_weight":122,"slug":123},21,"Paper Templates",5,"papers-templates",{"id":125,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":4,"slug":126},158,"general-158",{"code":4,"msg":82,"data":128},{"doc_id":79,"user_id":129,"nickname":42,"user_avatar":130,"doc_module":22,"category_id":125,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":136,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":12,"update_tm":140,"read_time":4},962090883219,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","viscosity conversion chart  \nKINEMATIC VISCOSITIES  \ncSt/ cSt/  \n40O C  \n2000  \n1000  \n800  \n600  \n500  \n400  \n300  \n200  \n100  \n80  \n60  \n50  \n40  \n30  \n20  \n100O C  \n70  \n60  \n50  \n40  \n30  \n20  \n10  \n9  \n8  \n7  \n6  \n5  \n4  \nAGMA ISO VG GRADES  \nSAE GRADES  \nMOTOR OILS  \nSAE GRADES  \nGEAR OILS  \n\n|  |  |  |\n| --- | --- | --- |\n| 1500 |  |  |\n|  |  |  |\n| \u003Cbr>1000 | \u003Cbr>8A | 250 |\n|  |  |  |\n| 680\u003Cbr>460 | 8 | 190 |\n|  | 7 | 140 |\n| \u003Cbr>320 | \u003Cbr>6 | 110 |\n| 220 | 5 | 50 |\n| \u003Cbr>150 | 4 | 90 |\n| \u003Cbr>100 | 3 | 40\u003Cbr>85 |\n| 68 | \u003Cbr>2 | 30\u003Cbr>80W |\n| 46 |  | 20 |\n|  | 1 | 75W |\n| 32 |  | 70W |\n| 22 |  | 10W |\n| 0W, 5W |  |  |\n| \u003Cbr>15 |  |  |\n\nSAYBOLT VISCOSITIES  \nSUS/ 100O F  \n10000  \n8000  \n6000  \n5000  \n4000  \n3000  \n2000  \n1500  \n1000  \n800  \n600  \n500  \n400  \n300  \n200  \n150  \n100  \n80  \n70  \nSUS/ 210O F  \n~~ ~~ 300  \n~~ ~~ 200  \n~~ ~~ 100  \n~~ ~~ 90  \n~~ ~~ 80  \n~~ ~~ 70  \n~~ ~~ 60  \n~~ ~~ 55  \n~~ ~~ 50  \n~~ ~~ 45  \n  40","cbCais5JCvHsU9uF","https://ap.wps.com/l/cbCais5JCvHsU9uF","pdf",1021988,"English","# Kinematic Viscosities\n## Viscosity Conversion Standards\n# Saybolt Viscosities\n## Grade Mapping","[{\"question\":\"What is the primary purpose of this chart?\",\"answer\":\"The chart serves as a reference for cross-referencing lubricant viscosities across different standards, including Kinematic Viscosity (cSt), Saybolt Viscosity (SUS), AGMA ISO VG grades, and SAE motor/gear oil grades.\"},{\"question\":\"Which temperature points are used for Kinematic Viscosity measurement in this document?\",\"answer\":\"The document provides Kinematic Viscosity values measured at both 40°C and 100°C.\"},{\"question\":\"How are Saybolt Viscosities represented in this chart?\",\"answer\":\"Saybolt Viscosities are represented as SUS (Saybolt Universal Seconds) values, specifically categorized for measurements taken at 100°F and 210°F.\"}]","Viscosity Conversion Chart | PDF",1791912583]