[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-166635-105":53,"doc-detail-166635-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","unisa-fit-out-baseline-document-table-of-contents","UNISA Fit-Out Baseline Document - Table of Contents","","UNISA Fit-Out Baseline Document provides guidelines for refurbishments, fit-out, and new construction projects across the University of South Africa. It supports compliance with SANS-10400 and NBR and includes direction for office-space allocation and design. Content covers sustainable design expectations, such as energy performance criteria, refrigerant restrictions, insulation requirements, indoor air quality, daylighting, and construction waste management, alongside general building planning duties, safety compliance, hazardous material remediation, and verification of existing building conditions.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":11,"@type":70,"position":76},"https://docshare.wps.com/template/presentations/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/unisa-fit-out-baseline-document-table-of-contents/166635/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/unisa-fit-out-baseline-document-table-of-contents/166635.png","ImageObject",442,249,{"name":88,"@type":89},"Olivia Brown","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/vnd.openxmlformats-officedocument.wordprocessingml.document","2026-09-20","2026-08-31",true,{"@type":98,"interactionType":99,"userInteractionCount":73},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What is the purpose of the UNISA Fit-Out Baseline Document?","Question",{"text":108,"@type":109},"It provides guidance for refurbishments, fit-out, and new construction projects at UNISA, including office-space allocation and design, for university personnel and external design and construction stakeholders.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"Which standards and compliance obligations are referenced?",{"text":113,"@type":109},"The document emphasizes compliance with SANS-10400 and NBR, including minimum standards and related regulations for building, fire, occupational health and safety, and barrier-free requirements.",{"name":115,"@type":106,"acceptedAnswer":116},"What sustainable design requirements are highlighted?",{"text":117,"@type":109},"It calls for meeting required energy and HVAC comfort criteria, using energy-performance requirements such as Energy Star where applicable, restricting CFC refrigerants, supporting local or sustainably sourced materials where possible, optimizing indoor air quality and ventilation, encouraging daylighting, and implementing construction waste management.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},166635,1788197106,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":8,"category_name":11,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":73,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":125,"read_time":15},16904993612988,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","UNIVERSITY OF SOUTH AFRICA FITOUT BASELINE DOCUMENT\nFacilities Management Department\nTABLE OF CONTENTS\n\u0003\u0013 HYPERLINK \\l \"_bookmark0\" \u0014TABLE OF CONTENTS\ti\u0015\n\u0013 HYPERLINK \\l \"_TOC_250005\" \u0014ACRONYMS\tii\u0015\n\u0013 HYPERLINK \\l \"_bookmark1\" \u0014INTRODUCTION\t3\u0015\n\u0013 HYPERLINK \\l \"_TOC_250004\" \u0014GENERAL REQUIREMENTS\t4\u0015\n\u0013 HYPERLINK \\l \"_bookmark2\" \u0014EXISTING BUILDING ENVELOPE COMPONENT\u0015\t8\nINTERIOR COMPONENT CONSTRUCTION\t9\nOPENINGS\t11\nFINISHES\t14\n\u0013 HYPERLINK \\l \"_bookmark3\" \u0014SPECIALTIES\u0015\t17\n\u0013 HYPERLINK \\l \"_TOC_250003\" \u0014CONVEYING SYSTEMS\t23\u0015\n\u0013 HYPERLINK \\l \"_TOC_250002\" \u0014FIRE SUPPRESSION\t24\u0015\nMECHANICAL,PLUMBING AND HVAC\t24\n\u0013 HYPERLINK \\l \"_TOC_250001\" \u0014ELECTRICAL\t28\u0015\nEXTERIOR IMPROVEMENTS\t31\n\u0013 HYPERLINK \\l \"_TOC_250000\" \u0014GLOSSARY\t33\u0015\u0004\nACRONYMS\nINTRODUCTION\nThe University of South Africa (UNISA) Fit-Out Baseline Document intends to provide guidelines and direction on the Refurbishment, Fit-Out & New Construction Projects at the University. Furthermore, UNISA recognizes its obligation towards compliance with the provisions of the SANS-10400 & NBR, in terms of compliance and the minimum standards required. UNISA is a comprehensive and open distance learning institution, which is comprised, of 7 Regional Centers across South Africa (SA) as depicted in Figure 1.1 below.\nThe “Fit-Out Baseline Document” was developed as reference for University Personnel, Associate Architects, Furniture Suppliers, Manufacturers, and Contractor Personnel who are involved in the design, Furnishing, Construction, and/or use of New and Renovated Office areas. It presents guidance for the allocation and design of Office Space at the University.\nThe guidance was developed through research of office environments in both higher education and other commercial industries.\nThe need for a comprehensive set of standards for the allocation and design for all University space has become apparent, and the precedent for this has been established.\nFigure1.1: UNISA Regional Centers\nGENERAL REQUIREMENTS\nSUSTAINABLE DESIGN\nIf identified in the Project Component Checklist, provide the design and construction required to obtain the GBCSA Rating required for the project.\nBuilding envelope and HVAC systems that establish temperature and humidity comfort ranges in accordance with SANS-10400 XA Energy Code are required. Specifics of insulation materials and installation will not be outlined here but must meet the SANS-10400 XA Energy Code. For existing buildings, the Design and Mechanical Engineering Division will assess the building envelope and HVAC systems.\nMeet Energy Star® performance criteria and when applicable, provide Energy Star® rated equipment and appliances.\nRequire zero use of CFC-based refrigerants for new systems; complete a comprehensive CFC phase-out conversion when reusing existing systems. Select refrigerants and HVAC systems that minimize emissions.\nWhen possible, specify or use products extracted, harvested, recovered or manufactured within a 100 Kilometers of the project site.\nWhen possible, specify and or use materials and products that are made of plants that are typically harvested within a ten-year or shorter cycle.\nDesign systems that meet or exceed minimum indoor air quality and ventilation requirements as well as optimizing air change effectiveness in accordance with SANS-10400 XA Energy Code.\nDesign structures to maximize daylight and views to the exterior consistent with the required function of interior building spaces. Daylight harvesting is encouraged but not required.\nImplement a construction waste management plan to minimize landfilling of construction waste in favor of reuse and recycling.\nGENERAL BUILDING PLANNING\nThe University premises shall be designed and constructed to meet or exceed the latest Local and National Building Regulations, Fire Regulations, Occupational Health & Safety Regulations and National Barrier Free Regulations.\nThe University premises designs shall be in such a manner as to ensure an economical and efficient use of space, adequate natural li","cbCaicE1fuMS0IpY","https://ap.wps.com/l/cbCaicE1fuMS0IpY","docx",580869,33,"English","# Acronyms\n# Introduction\n# General Requirements\n## Sustainable Design\n## General Building Planning\n# Existing Building Envelope Component\n## Interior Component Construction\n## Openings\n## Finishes\n# Specialties\n# Conveying Systems\n# Fire Suppression\n# Mechanical, Plumbing and HVAC\n# Electrical\n# Exterior Improvements\n# Glossary","[{\"question\":\"What is the purpose of the UNISA Fit-Out Baseline Document?\",\"answer\":\"It provides guidance for refurbishments, fit-out, and new construction projects at UNISA, including office-space allocation and design, for university personnel and external design and construction stakeholders.\"},{\"question\":\"Which standards and compliance obligations are referenced?\",\"answer\":\"The document emphasizes compliance with SANS-10400 and NBR, including minimum standards and related regulations for building, fire, occupational health and safety, and barrier-free requirements.\"},{\"question\":\"What sustainable design requirements are highlighted?\",\"answer\":\"It calls for meeting required energy and HVAC comfort criteria, using energy-performance requirements such as Energy Star where applicable, restricting CFC refrigerants, supporting local or sustainably sourced materials where possible, optimizing indoor air quality and ventilation, encouraging daylighting, and implementing construction waste management.\"}]","UNISA Fit-Out Baseline Document - Table of Contents | DOCX"]