[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-253250-105":53,"doc-detail-253250-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","terracore-panels-ac05-partial-scope-testing-two-adhesives-report","TERRACORE PANELS - AC05-Partial Scope Testing Two Adhesives - Report","","Scope of work covers partial scope AC05 testing of two adhesives, H. B. Fuller and Lushan, bonded to aluminum and fiberglass substrates to support a Class 2 adhesive designation. Intertek Building & Construction evaluates adhesion performance using referenced ICC-ESTM AC05 methods, with conditioning including control, accelerated aging, and water immersion. Results report mean strengths in psi for block shear, bond, oxidation, and ozone exposure. Testing records include dates, report identification, observer list, material sourcing, and retention requirements. The report clarifies it does not provide certification or endorsement.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":21,"@type":70,"position":76},"https://docshare.wps.com/template/invoices/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/terracore-panels-ac05-partial-scope-testing-two-adhesives-report/253250/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/terracore-panels-ac05-partial-scope-testing-two-adhesives-report/253250.png","ImageObject",442,249,{"name":88,"@type":89},"Aditya","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-17","2026-09-13",true,{"@type":98,"interactionType":99,"userInteractionCount":76},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What adhesives and bonded substrates are included in the AC05 partial scope testing?","Question",{"text":108,"@type":109},"The testing covers two adhesives, H. B. Fuller and Lushan, adhered to aluminum and fiberglass substrates.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"Which conditioning conditions are used to generate the mean strength results?",{"text":113,"@type":109},"Specimens are evaluated under control, accelerated aging, and water immersion/drying cycles as defined by the referenced AC05 sections.",{"name":115,"@type":106,"acceptedAnswer":116},"What standards and test methods govern the evaluation?",{"text":117,"@type":109},"The report uses ICC-ESTM AC05 (editorially revised July 2015) plus related ASTM test methods for tensile strength, shear properties, cyclic aging resistance, and oxidation/ozone-related degradation.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},253250,1790577241,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":20,"category_name":21,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":76,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":15},962085564549,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","TERRACORE PANELS, LLC  \nSCOPE OF WORK  \nAC05 (PARTIAL SCOPE) TESTING OF TWO ADHESIVES (H. B. FULLER AND LUSHAN) ADHERED TO ALUMINUM AND FIBERGLASS SUBSTRATES  \nREPORT NUMBER  \nH2716.01-106-31 R0  \nTEST DATE(S)  \n11/02/17-03/29/18  \nISSUE DATE  \n04/10/18  \nRECORD RETENTION END DATE  \n03/29/22  \nPAGES  \n35  \nDOCUMENT CONTROL NUMBER  \nATI 00231 (09/05/17) RT-R-AMER-Test-2827  \n© 2017 INTERTEK  \nREPORT ISSUED TO  \nTERRACORE PANELS, LLC  \n2030 Irving Boulevard, Dallas, Texas 75207  \nSECTION 1  \nSCOPE  \nProducts: Two adhesives (H. B. Fuller and Lushan) adhered to aluminium and fiberglass substrates  \nIntertek Building & Construction (B&C) was contracted by TerraCore Panels, LLC, to evaluate two adhesives (H. B. Fuller and Lushan) in accordance with the referenced sections of ICC-ESTM AC05 as required for a Class 2 adhesive designation. Results obtained are tested values and were secured by using the designated test method(s) . Testing was conducted at the Intertek B&C test facility in York, Pennsylvania, with oxidation and ozone exposure conducted at separate facilities referenced herein.  \nThis report does not constitute certification of this product nor an opinion or endorsement by this laboratory.  \nFor INTERTEK B&C:  \n\n| COMPLETED BY: | Andrew D. Cook | REVIEWED BY: | Scott D. Scallorn |\n| --- | --- | --- | --- |\n| TITLE: | Technician II\u003Cbr>Materials Laboratory | TITLE: | Project Engineer Materials Laboratory |\n| SIGNATURE: |  | SIGNATURE: |  |\n| DATE: | 04/10/18 | DATE: | 04/10/18 |\n\nADC:sds/kf  \nSECTION 2  \nSUMMARY OF TEST RESULTS  \n\n| TEST COMPONENT |  | ADHESIVE | BONDED SUBSTRATES | CONDITIONING | MEAN RESULTS (psi) |\n| --- | --- | --- | --- | --- | --- |\n| AC05 SECTION | DESCRIPTION |  |  |  |  |\n| 8.3 | Block Shear | H. B. Fuller | Aluminum\u003Cbr>Aluminum | Control | 2,736 |\n|  |  |  |  | Accelerated Aging | 3,019 (+10.3%) |\n|  |  |  |  | Water Immersion | 2,398 (-12.4%) |\n|  |  |  | Aluminum\u003Cbr>Fiberglass | Control | 1,753 |\n|  |  |  |  | Accelerated Aging | 1,955 (+11 .5%) |\n|  |  |  |  | Water Immersion | 1,744 (-0 .05%) |\n| 8.5 | Bond | H. B. Fuller | Aluminum\u003Cbr>Aluminum | Control | 729 |\n|  |  |  |  | Accelerated Aging | 759 (+4 . 1%) |\n|  |  |  |  | Water Immersion | 625 (-14 .3%) |\n|  |  |  | Aluminum\u003Cbr>Fiberglass | Control | 491 |\n|  |  |  |  | Accelerated Aging | 546 (+11 . 2%) |\n|  |  |  |  | Water Immersion | 568 (+15 .7%) |\n| 8.7 | Oxidation | H. B. Fuller | Aluminum\u003Cbr>Aluminum | Control | 2,141 |\n|  |  |  |  | Post-Oxidation | 1,948 (-9 . 1%) |\n| 8.7.2 | Ozone | H. B. Fuller | Aluminum\u003Cbr>Aluminum | Control | 2,141 |\n|  |  |  |  | Post-Ozone | 1,918 (-10 .4%) |\n|  |  | Lushan | Aluminum\u003Cbr>Aluminum | Control | 1,040 |\n|  |  |  |  | Post-Ozone | 897 (-13 .8%) |\n\nSECTION 3  \nTEST METHODS  \nThe specimens were evaluated in accordance with the following, as governed by ICC-ESTM AC05:  \nICC-ESTM AC05 (Editorially Revised July 2015), Acceptance Criteria for Sandwich Panel Adhesives  \nASTM C297/C297M-16, Standard Test Method for Flatwise Tensile Strength of Sandwich Constructions  \nASTM D905-08 (2013), Standard Test Method for Strength Properties of Adhesive Bonds in Shear by Compressive Loading  \nASTM D1002-10, Standard Test Method for Apparent Shear Strength of Single-Lap-Joint Adhesively Bonded Metal Specimens by Tension Loading (Metal-to-Metal)  \nASTM D1183-03 (2011), Standard Practices for Resistance of Adhesives to Cyclic Laboratory Aging Conditions  \nASTM D572-04 (2015), Standard Test Method for Rubber-Deterioration by Heat and Oxygen ASTM D1149-07 (2012), Standard Test Methods for Rubber Deterioration - Cracking in an Ozone Controlled Environment  \nSECTION 4  \nMATERIAL SOURCE  \nThe materials were selected by Intertek B&C personnel at Allcomb: Sanjiang Village, Leping Town, Sanshui District, Foshan, Guangdong Province, China. The materials were tagged prior to shipment on 07/19/2017, (Reference Intertek B&C Test Specimen Selection Report No. 170719023GZU_ATI_Pacific sampling July 19, 2017_H2716 .01, dated 07/1","cbCaieYg7Dp2hzsl","https://ap.wps.com/l/cbCaieYg7Dp2hzsl","pdf",2706787,35,"English","# Section 1: Scope\n## Products and evaluation basis\n# Section 2: Summary of test results\n## Block shear, bond, oxidation, ozone (mean results)\n# Section 3: Test methods\n## ICC-ESTM AC05 and ASTM methods\n# Section 4: Material source\n## Selection, tagging, and specimen preparation\n# Section 5: List of official observers\n# Section 6: Test procedures\n## AC05 Section 8.3 block shear testing","[{\"question\":\"What adhesives and bonded substrates are included in the AC05 partial scope testing?\",\"answer\":\"The testing covers two adhesives, H. B. Fuller and Lushan, adhered to aluminum and fiberglass substrates.\"},{\"question\":\"Which conditioning conditions are used to generate the mean strength results?\",\"answer\":\"Specimens are evaluated under control, accelerated aging, and water immersion/drying cycles as defined by the referenced AC05 sections.\"},{\"question\":\"What standards and test methods govern the evaluation?\",\"answer\":\"The report uses ICC-ESTM AC05 (editorially revised July 2015) plus related ASTM test methods for tensile strength, shear properties, cyclic aging resistance, and oxidation/ozone-related degradation.\"}]","TERRACORE PANELS - AC05-Partial Scope Testing Two Adhesives - Report | PDF",1789264902]