[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-563333-105":53,"doc-detail-563333-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","temperature-pressure-chart-activestatic-pressure-tables-for-r410a","Temperature-Pressure-Chart - Active/Static Pressure Tables for R410A","","Pressure-temperature reference tables for refrigerant R410A, including service-port active pressure when the compressor runs outside, and heating/cooling active-pressure charts. Provides BAR, PSI, and MPa conversions at multiple ODU/IDU dry-bulb and wet-bulb temperature pairs. Also includes a static system pressure table labeled STATIC PRESSURE (compressor not running outside), mapping Kpa/bar/PSI against temperature in °C and °F across a wide range for engineering and service checks.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/temperature-pressure-chart-activestatic-pressure-tables-for-r410a/563333/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/temperature-pressure-chart-activestatic-pressure-tables-for-r410a/563333.png","ImageObject",442,249,{"name":88,"@type":89},"Cart","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-30","2026-10-12",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",7,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What refrigerant and pressure modes are covered in the chart?","Question",{"text":109,"@type":110},"The document covers R410A and provides both active pressure (compressor running outside) charts and a static system pressure table (compressor not running outside).","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"Which units and axes are used for the active pressure tables?",{"text":114,"@type":110},"The active charts present pressure in BAR/PSI/MPa and temperature combinations shown as ODU(DB) and IDU(DB/WB) or ODU/IDU dry-bulb and wet-bulb values, labeled in °F(°C).",{"name":116,"@type":107,"acceptedAnswer":117},"How is static pressure provided in the R410A system pressure table?",{"text":118,"@type":110},"The static pressure table maps Kpa, bar, and PSI values to corresponding temperatures in °C and °F, enabling lookup of pressure based on temperature without compressor operation outside.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},563333,1792086207,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":76,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":9},18829141979164,"https://eur-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","iii) Pressure On Service Port  \nCooling chart(R410A): ACTIVE PRESSURE (Compressor running outside)  \n\n| °F(°C) | ODU(DB) IDU(DB/WB) | 0(-17) | 5(-15) | 15\u003Cbr>(-9.44) | 45\u003Cbr>(7.22) | 75\u003Cbr>(23.89) | 85\u003Cbr>(29.44) | 95 (35) | 105\u003Cbr>(40.56) | 115\u003Cbr>(46.11) | 120\u003Cbr>(48.89) |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| BAR | 70/59 (21 .11/15) | 6.4 | 6.5 | 7.3 | 8.0 | 8.2 | 7.8 | 8.1 | 8.6 | 10.1 | 10.6 |\n|  | 75/63 (23 . 89/17 . 22) | 6.7 | 6.8 | 7.9 | 8.6 | 8.6 | 8.3 | 8.7 | 9.1 | 10.7 | 11.2 |\n|  | 80/67 (26 . 67/19 . 44) | 7.1 | 7.2 | 8.5 | 9.5 | 9.3 | 8.9 | 9.1 | 9.6 | 11.2 | 11.9 |\n|  | 90/73 (32 . 22/22 . 78) | 7.7 | 7.8 | 9.6 | 10.5 | 10.3 | 9.5 | 10.0 | 10.6 | 12.4 | 13.0 |\n| PSI | 70/59 (21 .11/15) | 93 | 94 | 106 | 116 | 119 | 113 | 117 | 125 | 147 | 154 |\n|  | 75/63 (23 . 89/17 . 22) | 97 | 99 | 115 | 125 | 124 | 120 | 126 | 132 | 155 | 162 |\n|  | 80/67 (26 . 67/19 . 44) | 103 | 104 | 123 | 138 | 135 | 129 | 132 | 140 | 162 | 173 |\n|  | 90/73 (32 . 22/22 . 78) | 112 | 113 | 139 | 152 | 149 | 138 | 145 | 154 | 180 | 189 |\n| MPa | 70/59 (21 .11/15) | 0.64 | 0.65 | 0.73 | 0.8 | 0.82 | 0.78 | 0.81 | 0.86 | 1.01 | 1.06 |\n|  | 75/63 (23 . 89/17 . 22) | 0.67 | 0.68 | 0.79 | 0.86 | 0.86 | 0.83 | 0.87 | 0.91 | 1.07 | 1.12 |\n|  | 80/67 (26 . 67/19 . 44) | 0.71 | 0.72 | 0.85 | 0.95 | 0.93 | 0.89 | 0.91 | 0.96 | 1.12 | 1.19 |\n|  | 90/73 (32 . 22/22 . 78) | 0.77 | 0.78 | 0.96 | 1.05 | 1.03 | 0.95 | 1 | 1.06 | 1.24 | 1.3 |\n\n\n| 1.4\u003Cbr>1.2\u003Cbr>1\u003Cbr>0.8\u003Cbr>0.6\u003Cbr>0.4\u003Cbr>0.2\u003Cbr>0 | |  |  |  70/59\u003Cbr>75/63 80/67 90/73 |\n| --- | --- | --- | --- | --- |\n|  | | | |  |\n\nHeating chart (R410A) : ACTIVE PRESSURE (Compressor running outside)  \n\n| °F(°C) | ODU(DB/WB) IDU(DB) | 57/53\u003Cbr>(13.89/11.67) | 47/43\u003Cbr>(8.33/6.11) | 37/33\u003Cbr>(2.78/0.56) | 27/23\u003Cbr>(-2.78/-5) | 17/13\u003Cbr>(-8.33/-10.56) | 0/-2\u003Cbr>(-17/-19) | -17/-18\u003Cbr>(-27/-28) |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| BAR | 55(12.78) | 30.3 | 28.5 | 25.3 | 22.8 | 20.8 | 18.5 | 16.5 |\n|  | 65(18.33) | 32.5 | 30.0 | 26.6 | 25.4 | 23.3 | 20.5 | 19.0 |\n|  | 75(23.89) | 33.8 | 31.5 | 27.8 | 26.3 | 24.9 | 21.5 | 20.0 |\n| PSI | 55(12.78) | 439 | 413 | 367 | 330 | 302 | 268 | 239 |\n|  | 65(18.33) | 471 | 435 | 386 | 368 | 339 | 297 | 276 |\n|  | 75(23.89) | 489 | 457 | 403 | 381 | 362 | 312 | 290 |\n| MPa | 55(12.78) | 3.03 | 2.85 | 2.53 | 2.28 | 2.08 | 1.85 | 1.65 |\n|  | 65(18.33) | 3.25 | 3.00 | 2.66 | 2.54 | 2.33 | 2.05 | 1.90 |\n|  | 75(23.89) | 3.38 | 3.15 | 2.78 | 2.63 | 2.49 | 2.15 | 2.00 |\n\n\n| 4\u003Cbr>3.5\u003Cbr>3\u003Cbr>2.5\u003Cbr>2\u003Cbr>1.5\u003Cbr>1\u003Cbr>0.5\u003Cbr>0 |  |\n| --- | --- |\n|  | |\n|  | |\n|  | |\n|  | |\n|  |  |\n|  |  |\n|  |  |\n\n55  \n65  \n75  \nSystem Pressure Table-R410A STATIC PRESSURE (Compressor not running outside)  \n\n| Pressure |  |  | Temperature |  | Pressure |  |  | Temperature |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Kpa | bar | PSI | °C | °F | Kpa | bar | PSI | °C | °F |\n| 100 | 1 | 14.5 | -51.623 | -60.921 | 2350 | 23.5 | 340.75 | 38.817 | 101.871 |\n| 150 | 1.5 | 21.75 | -43.327 | -45.989 | 2400 | 24 | 348 | 39.68 | 103.424 |\n| 200 | 2 | 29 | -36.992 | -34.586 | 2450 | 24.5 | 355.25 | 40.531 | 104.956 |\n| 250 | 2.5 | 36.25 | -31.795 | -25.231 | 2500 | 25 | 362.5 | 41.368 | 106.462 |\n| 300 | 3 | 43.5 | -27.351 | -17.232 | 2550 | 25.5 | 369.75 | 42.192 | 107.946 |\n| 350 | 3.5 | 50.75 | -23.448 | -10.206 | 2600 | 26 | 377 | 43.004 | 109.407 |\n| 400 | 4 | 58 | -19.953 | -3.915 | 2650 | 26.5 | 384.25 | 43.804 | 110.847 |\n| 450 | 4.5 | 65.25 | -16.779 | 1.798 | 2700 | 27 | 391.5 | 44.592 | 112.266 |\n| 500 | 5 | 72.5 | -13.863 | 7.047 | 2750 | 27.5 | 398.75 | 45.37 | 113.666 |\n| 550 | 5.5 | 79.75 | -11.162 | 11.908 | 2800 | 28 | 406 | 46.136 | 115.045 |\n| 600 | 6 | 87 | -8.643 | 16.444 | 2850 | 28.5 | 413.25 | 46.892 | 116.406 |\n| 650 | 6.5 | 94.25 | -6.277 | 20.701 | 2900 | 29 | 420.5 | 47.638 | 117.748 |\n| 700 | 7 | 101.5 | -4.046 | 24.716 | 2950 | 29.5 | 427.75 | 48.374 | 119.073 |\n| 750 | 7.5 | 108.75 | -1.933 | 28.521 | ","cbCaithwyRsreWzt","https://ap.wps.com/l/cbCaithwyRsreWzt","pdf",1271167,"English","# Pressure On Service Port\n## Cooling chart (R410A) - Active pressure\n## Heating chart (R410A) - Active pressure\n## System Pressure Table - R410A STATIC PRESSURE","[{\"question\":\"What refrigerant and pressure modes are covered in the chart?\",\"answer\":\"The document covers R410A and provides both active pressure (compressor running outside) charts and a static system pressure table (compressor not running outside).\"},{\"question\":\"Which units and axes are used for the active pressure tables?\",\"answer\":\"The active charts present pressure in BAR/PSI/MPa and temperature combinations shown as ODU(DB) and IDU(DB/WB) or ODU/IDU dry-bulb and wet-bulb values, labeled in °F(°C).\"},{\"question\":\"How is static pressure provided in the R410A system pressure table?\",\"answer\":\"The static pressure table maps Kpa, bar, and PSI values to corresponding temperatures in °C and °F, enabling lookup of pressure based on temperature without compressor operation outside.\"}]","Temperature-Pressure-Chart - Active/Static Pressure Tables for R410A | PDF",1791829614]