[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-568792-105":3,"detail-sidebar-cat-1-en-105":81,"doc-detail-568792-en":127},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","temperature-compensated-battery-state-of-charge-soc-table","Temperature Compensated Battery State-of-Charge (SoC) Table","","Temperature compensated battery state-of-charge (SoC) table providing reference readings across electrolyte temperatures in both Fahrenheit and Celsius. For each temperature, the table lists specific gravity readings at 100%, 75%, 50%, 25%, and 0% SoC, plus open-circuit voltage readings for multiple battery types. It includes values for wet low maintenance/standard batteries and for “maintenance free” and AGM/Gel VRLA batteries, facilitating estimation of charge using measured temperature-dependent parameters.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/general/","General",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/temperature-compensated-battery-state-of-charge-soc-table/568792/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/temperature-compensated-battery-state-of-charge-soc-table/568792.png","ImageObject",442,249,{"name":42,"@type":43},"Fahsai","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-22","2026-10-13",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"How does the table help estimate battery state-of-charge (SoC)?","Question",{"text":63,"@type":64},"It links measured electrolyte temperature to expected specific gravity and open-circuit voltage values at defined SoC levels (100%, 75%, 50%, 25%, 0%).","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What readings are provided for each temperature in the table?",{"text":68,"@type":64},"The table includes electrolyte temperature in both degrees Fahrenheit and degrees Celsius.",{"name":70,"@type":61,"acceptedAnswer":71},"Which battery chemistries/types does the table cover?",{"text":72,"@type":64},"It lists wet low maintenance (Sb/Ca) or wet standard (Sb/Sb) batteries and also wet “maintenance free” (Ca/Ca) plus AGM/Gel cell VRLA batteries (Ca/Ca).","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},568792,1792107652,{"code":4,"msg":82,"data":83},"success",[84,89,94,99,104,109,114,119,124],{"id":85,"doc_module":22,"doc_module_name":25,"category_name":86,"show_sort_weight":87,"slug":88},11,"Presentations",90,"presentations",{"id":90,"doc_module":22,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},12,"Resumes",80,"resumes",{"id":95,"doc_module":22,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},14,"Invoices",70,"invoices",{"id":100,"doc_module":22,"doc_module_name":25,"category_name":101,"show_sort_weight":102,"slug":103},15,"Posters",60,"posters",{"id":105,"doc_module":22,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},16,"Social Media",50,"social-media",{"id":110,"doc_module":22,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},17,"Forms",40,"forms",{"id":115,"doc_module":22,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},18,"Letters",30,"letters",{"id":120,"doc_module":22,"doc_module_name":25,"category_name":121,"show_sort_weight":122,"slug":123},21,"Paper Templates",5,"papers-templates",{"id":125,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":4,"slug":126},158,"general-158",{"code":4,"msg":82,"data":128},{"doc_id":79,"user_id":129,"nickname":42,"user_avatar":130,"doc_module":22,"category_id":125,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":136,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":12,"update_tm":140,"read_time":4},549768702563,"https://ap-avatar.wpscdn.com/avatar/8000c4aa63b76e948b?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786536092046926083","TEMPERATURE COMPENSATED BATTERY STATE-OF-CHARGE (SoC) TABLE  \n\n| Electrolyte\u003Cbr>Temperature |  | Wet Low Maintenance (Sb/Ca) or Wet Standard (Sb/Sb) Battery |  |  |  |  |  |  |  |  |  | Wet \"Mainteneance Free\" (Ca/Ca) or AGM/Gel Cell VRLA (Ca/Ca) Battery |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  | Specific Gravity Reading |  |  |  |  | Open Circuit Voltage Reading |  |  |  |  | Open Circuit Voltage Reading |  |  |  |  |\n| Degrees\u003Cbr>Fahrenheit | Degrees\u003Cbr>Celsius | 100%\u003Cbr>SoC | 75%\u003Cbr>SoC | 50%\u003Cbr>SoC | 25%\u003Cbr>SoC | 0%\u003Cbr>SoC | 100%\u003Cbr>SoC | 75%\u003Cbr>SoC | 50%\u003Cbr>SoC | 25%\u003Cbr>SoC | 0%\u003Cbr>SoC | 100%\u003Cbr>SoC | 75%\u003Cbr>SoC | 50%\u003Cbr>SoC | 25%\u003Cbr>SoC | 0%\u003Cbr>SoC |\n| 120 | 48.9 | 1.249 | 1.209 | 1.174 | 1.139 | 1.104 | 12.663 | 12.463 | 12.253 | 12.073 | 11.903 | 12.813 | 12.613 | 12.413 | 12.013 | 11.813 |\n| 110 | 43.3 | 1.253 | 1.213 | 1.178 | 1.143 | 1.108 | 12.661 | 12.461 | 12.251 | 12.071 | 11.901 | 12.811 | 12.611 | 12.411 | 12.011 | 11.811 |\n| 100 | 37.8 | 1.257 | 1.217 | 1.182 | 1.147 | 1.112 | 12.658 | 12.458 | 12.248 | 12.068 | 11.898 | 12.808 | 12.608 | 12.408 | 12.008 | 11.808 |\n| 90 | 32.2 | 1.261 | 1.221 | 1.186 | 1.151 | 1.116 | 12.655 | 12.455 | 12.245 | 12.065 | 11.895 | 12.805 | 12.605 | 12.405 | 12.005 | 11.805 |\n| 80 | 26.7 | 1.265 | 1.225 | 1.190 | 1.155 | 1.120 | 12.650 | 12.450 | 12.240 | 12.060 | 11.890 | 12.800 | 12.600 | 12.400 | 12.000 | 11.800 |\n| 70 | 21.1 | 1.269 | 1.229 | 1.194 | 1.159 | 1.124 | 12.643 | 12.443 | 12.233 | 12.053 | 11.883 | 12.793 | 12.593 | 12.393 | 11.993 | 11.793 |\n| 60 | 15.6 | 1.273 | 1.233 | 1.198 | 1.163 | 1.128 | 12.634 | 12.434 | 12.224 | 12.044 | 11.874 | 12.784 | 12.584 | 12.384 | 11.984 | 11.784 |\n| 50 | 10.0 | 1.277 | 1.237 | 1.202 | 1.167 | 1.132 | 12.622 | 12.422 | 12.212 | 12.032 | 11.862 | 12.772 | 12.572 | 12.372 | 11.972 | 11.772 |\n| 40 | 4.4 | 1.281 | 1.241 | 1.206 | 1.171 | 1.136 | 12.606 | 12.406 | 12.196 | 12.016 | 11.846 | 12.756 | 12.556 | 12.356 | 11.956 | 11.756 |\n| 30 | -1.1 | 1.285 | 1.245 | 1.210 | 1.175 | 1.140 | 12.588 | 12.388 | 12.178 | 11.998 | 11.828 | 12.738 | 12.538 | 12.338 | 11.938 | 11.738 |\n| 20 | -6.7 | 1.289 | 1.249 | 1.214 | 1.179 | 1.144 | 12.566 | 12.366 | 12.156 | 11.976 | 11.806 | 12.716 | 12.516 | 12.316 | 11.916 | 11.716 |\n| 10 | -12.2 | 1.293 | 1.253 | 1.218 | 1.183 | 1.148 | 12.542 | 12.342 | 12.132 | 11.952 | 11.782 | 12.692 | 12.492 | 12.292 | 11.892 | 11.692 |\n| 0 | -17.8 | 1.297 | 1.257 | 1.222 | 1.187 | 1.152 | 12.516 | 12.316 | 12.106 | 11.926 | 11.756 | 12.666 | 12.466 | 12.266 | 11.866 | 11.666 |\n\n[www.batteryfaq.org](www.batteryfaq.org)","cbCaigOA8mMU7TcO","https://ap.wps.com/l/cbCaigOA8mMU7TcO","pdf",16226,"English","# Temperature-Compensated SoC Table\n## Specific Gravity Readings by Electrolyte Temperature\n## Open Circuit Voltage Readings by SoC and Battery Type","[{\"question\":\"How does the table help estimate battery state-of-charge (SoC)?\",\"answer\":\"It links measured electrolyte temperature to expected specific gravity and open-circuit voltage values at defined SoC levels (100%, 75%, 50%, 25%, 0%).\"},{\"question\":\"What readings are provided for each temperature in the table?\",\"answer\":\"The table includes electrolyte temperature in both degrees Fahrenheit and degrees Celsius.\"},{\"question\":\"Which battery chemistries/types does the table cover?\",\"answer\":\"It lists wet low maintenance (Sb/Ca) or wet standard (Sb/Sb) batteries and also wet “maintenance free” (Ca/Ca) plus AGM/Gel cell VRLA batteries (Ca/Ca).\"}]","Temperature Compensated Battery State-of-Charge (SoC) Table | PDF",1791872392]