[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-175590-105":53,"doc-detail-175590-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","submittal-procedures-finish-carpentry-cabinet-hardware-general-requirements","Submittal Procedures - Finish Carpentry - Cabinet Hardware - General Requirements","","General requirements for cabinet hardware within construction specifications. Covers related sections on submittals, common product requirements, waste management, and closeout deliverables. Defines required submittals including product data, hardware lists, and manufacturer installation instructions, plus closeout maintenance data, parts lists, and instructions for maintenance manuals. Provides delivery, storage, and handling rules; specifies ANSI/BHMA cabinet hardware types, finishes, and functions; and sets execution steps for installation, adjusting, cleaning, and keying system setup with staff briefing and documentation.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":36,"@type":70,"position":76},"https://docshare.wps.com/template/forms/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/submittal-procedures-finish-carpentry-cabinet-hardware-general-requirements/175590/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/submittal-procedures-finish-carpentry-cabinet-hardware-general-requirements/175590.png","ImageObject",442,249,{"name":88,"@type":89},"\tCallum ","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/octet-stream","2026-10-22","2026-09-02",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",13,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What submittals are required for cabinet hardware?","Question",{"text":109,"@type":110},"Submit manufacturer product data, a contract hardware list with make/model/material/function/finish, and installation instructions. Closeout submittals also require maintenance data, parts lists, and manufacturer instructions for the maintenance manual.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"How should hardware materials be delivered and stored?",{"text":114,"@type":110},"Deliver, store, handle, and protect materials per common product requirements. Store cabinet hardware in a locked, clean, dry area and package fastenings separately or in like groups with labeled item definitions and locations.",{"name":116,"@type":107,"acceptedAnswer":117},"What does the specification require for keying cabinets locks?",{"text":118,"@type":110},"Locks must be keyed alike within a room or as directed, with a keying schedule submitted for approval. Provide duplicate keys for every lock type, and stamp keying code numbers on keys and cylinders. A key control setup and staff briefing are also required.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},175590,1788320977,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":35,"category_name":36,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":79,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":126,"read_time":73},137451211410,"https://ap-avatar.wpscdn.com/avatar/2000bb0a9246f588df?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786362646172706240","GENERAL\nRELATED SECTIONS\nSection 01 33 00 - Submittal Procedures.\nSection 01 61 00 - Common Product Requirements.\nSection 01 74 21 – Construction/Demolition Waste Management and Disposal.\nSection 01 78 00 - Closeout Submittals.\nSection 06 20 00 - Finish Carpentry.\nSection 06 40 00 - Architectural Woodwork.\nREFERENCES\nAmerican National Standards Institute (ANSI) / Builders Hardware Manufacturers Association (BHMA)\nANSI/BHMA A156.9, Cabinet Hardware.\nANSI/BHMA A156.11, Cabinet Locks.\nANSI/BHMA A156.16, Auxiliary Hardware.\nANSI/BHMA A156.18, Materials and Finishes.\nSUBMITTALS\nProduct Data:\nSubmit manufacturer's printed product literature, specifications and data sheet.\nHardware List:\nSubmit contract hardware list.\nIndicate specified hardware, including make, model, material, function, finish and other pertinent information.\nManufacturer's Instructions:\nSubmit manufacturer's installation instructions.\nCloseout Submittals:\nProvide maintenance data, parts list, and manufacturer's instructions for incorporation into maintenance manual specified in Section 01 78 00 - Closeout Submittals.\nDELIVERY, STORAGE, AND HANDLING\nDeliver, store, handle and protect materials in accordance with Section 01 61 00 - Common Product Requirements.\nStore cabinet hardware in locked, clean and dry area.\nPackage items of hardware including fastenings, separately or in like groups of hardware, label each package as to item definition and location.\nPRODUCTS\nHARDWARE ITEMS\nUse one manufacturer's product for all similar items.\nCABINET HARDWARE\nCabinet hardware: to ANSI/BNMA A156.9, designated by letter B and numeral identifiers listed in Hardware Schedule indicated on drawings.\nHinges:  European style hinge with 110° swing of operation for face frame construction cabinets.\nPulls: surface mounted pull.\nKnobs: surface mounted knob.\nLatches: elbow latch.\nCatches: friction catch.\nShelf rests and standards: adjustable shelf standards, with open shelf rests.\nShelf brackets and standards: vertical slotted shelf standard, with shelf brackets.\nDrawer slides: side mounted drawer slides.\nTrack and guides for sliding panels: surface or recessed mounted with anti-friction inserts.\nCabinet locks: to ANSI/BNMA A156.11, designated by letter E and numeral identifiers listed in Hardware Schedule.\nDoor or drawer locks: half mortised into back of door or drawer\nCylinders: key to keying system as directed\nFASTENINGS\nSupply screws, bolts, expansion shields and other fastening devices required for satisfactory installation and operation of hardware.\nExposed fastening devices to match finish of hardware.\nUse fasteners compatible with material through which they pass.\nKEYING\nCabinet locks to be as keyed alike in a room or as directed. Submit keying schedule for approval.\nProvide keys in duplicate for every type of lock in this Contract.\nStamp keying code numbers on keys and cylinders.\nEXECUTION\nMANUFACTURER'S INSTRUCTIONS\nCompliance: comply with manufacturer's written data, including product technical bulletins, product catalogue installation instructions, product carton installation instructions, and data sheets.\nINSTALLATION\nInstall hardware to standard hardware location dimensions in accordance with manufacturer's recommendations and to project design requirements.\nADJUSTING\nLubricate hardware and other moving parts, as recommended by manufacturer.\nAdjust cabinet door hardware to provide tight fit at contact points with frames.\nCLEANING\nPerform cleaning after installation to remove construction and accumulated environmental dirt.\nClean hardware with damp rag and approved non-abrasive cleaner, and polish hardware in accordance with manufacture's instructions.\nRemove protective material from hardware items where present.\nUpon completion of installation, remove surplus materials, rubbish, tools and equipment barriers.\nDEMONSTRATION\nKeying System Setup:\nSet up key control system with file key tags, duplicate key tags, numerical index, alphabetical index and key change index, label shiel","cbCaiersgk1ENakj","https://ap.wps.com/l/cbCaiersgk1ENakj","doc",55296,"English","# Submittals\n## Product Data\n## Hardware List\n## Manufacturer's Instructions\n## Closeout Submittals\n# Delivery, Storage, and Handling\n# Products: Hardware Items\n## Cabinet Hardware\n## Fastenings\n## Keying\n# Execution\n## Manufacturer's Instructions\n## Installation\n## Adjusting\n## Cleaning\n## Demonstration: Keying System Setup","[{\"question\":\"What submittals are required for cabinet hardware?\",\"answer\":\"Submit manufacturer product data, a contract hardware list with make/model/material/function/finish, and installation instructions. Closeout submittals also require maintenance data, parts lists, and manufacturer instructions for the maintenance manual.\"},{\"question\":\"How should hardware materials be delivered and stored?\",\"answer\":\"Deliver, store, handle, and protect materials per common product requirements. Store cabinet hardware in a locked, clean, dry area and package fastenings separately or in like groups with labeled item definitions and locations.\"},{\"question\":\"What does the specification require for keying cabinets locks?\",\"answer\":\"Locks must be keyed alike within a room or as directed, with a keying schedule submitted for approval. Provide duplicate keys for every lock type, and stamp keying code numbers on keys and cylinders. A key control setup and staff briefing are also required.\"}]","Submittal Procedures - Finish Carpentry - Cabinet Hardware - General Requirements | DOC"]