[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-565415-105":53,"doc-detail-565415-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","small-animal-exposure-chart-computerised-radiography-cr-suggested-exposures","Small Animal Exposure Chart - Computerised Radiography (CR) - Suggested Exposures","","Small animal exposure chart for Computerised Radiography (CR) systems providing suggested and adjusted exposure settings. Values are given for a Focal Spot/Film Distance (FFD) of 100 cm and specify how to compensate when using a grid by doubling mAs or adding 10 kV. Coverage includes multiple views and anatomical regions such as thorax, abdomen, pelvis/hips, extremities, skull, and spinal series, tabulated by patient thickness for cats/small dogs, medium dogs, and large dogs.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/small-animal-exposure-chart-computerised-radiography-cr-suggested-exposures/565415/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/small-animal-exposure-chart-computerised-radiography-cr-suggested-exposures/565415.png","ImageObject",442,249,{"name":88,"@type":89},"Bintang","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-31","2026-10-13",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",6,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What are the assumptions for the suggested exposure settings in this chart?","Question",{"text":109,"@type":110},"The suggested exposures are for a Focal Spot/Film Distance (FFD) of 100 cm and without a grid.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"How should exposure be adjusted when a grid is used?",{"text":114,"@type":110},"When using a grid, double the mAs or add 10 kV to the suggested settings.",{"name":116,"@type":107,"acceptedAnswer":117},"How are the exposure values organized for different patients and anatomy?",{"text":118,"@type":110},"Tables are separated by anatomical region and view (e.g., thorax, abdomen, pelvis/hips, spine) and list values by patient thickness for cat/small dog, medium dog, and large dog.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},565415,1792124713,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":76,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":9},962085564381,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Small animal exposure chart Computerised Radiography systems (CR)  \nSuggested exposures are for a Focal Spot/Film Distance (FFD) of 100cm without a grid If using a grid double the mAs or add 10kV  \nThorax – lateral view  \n\n| Thickness\u003Cbr>(cm) | Suggested\u003Cbr>kV | Suggested\u003Cbr>mAs | Adjusted\u003Cbr>kV | Adjusted\u003Cbr>mAs |\n| --- | --- | --- | --- | --- |\n| Cat/Small Dog |  |  |  |  |\n| 7 | 60 | 2 |  |  |\n| 9 | 62 | 2 |  |  |\n| 12 | 70 | 2.4 |  |  |\n| 15 | 73 | 2.4 |  |  |\n| Medium Dog |  |  |  |  |\n| 18 | 75 | 2.4 |  |  |\n| 21 | 80 | 3.2 |  |  |\n| 23 | 85 | 3.2 |  |  |\n| Large Dog |  |  |  |  |\n| 25-30 | 80-90 | 4-6 |  |  |\n\nAbdomen – lateral view  \n\n| Thickness\u003Cbr>(cm) | Suggested\u003Cbr>kV | Suggested\u003Cbr>mAs | Adjusted\u003Cbr>kV | Adjusted\u003Cbr>mAs |\n| --- | --- | --- | --- | --- |\n| Cat/Small Dog |  |  |  |  |\n| 4-6 | 52 | 2.4 |  |  |\n| 8 | 52 | 3.2 |  |  |\n| 10 | 55 | 3.2 |  |  |\n| 12 | 55 | 4.5 |  |  |\n| 14 | 60 | 5 |  |  |\n| 16 | 65 | 6 |  |  |\n| Medium Dog |  |  |  |  |\n| 18 | 70 | 7 |  |  |\n| 20 | 75 | 7 |  |  |\n| 22 | 80 | 8 |  |  |\n| Large Dog |  |  |  |  |\n| 24-30 | 80 | 8-12 |  |  |\n\nThorax – VD/DV view  \n\n| Thickness\u003Cbr>(cm) | Suggested\u003Cbr>kV | Suggested\u003Cbr>mAs | Adjusted\u003Cbr>kV | Adjusted\u003Cbr>mAs |\n| --- | --- | --- | --- | --- |\n| Cat/Small Dog |  |  |  |  |\n| 7 | 60 | 2 |  |  |\n| 9 | 65 | 2 |  |  |\n| 12 | 70 | 2 |  |  |\n| 15 | 73 | 2.4 |  |  |\n| Medium Dog |  |  |  |  |\n| 18 | 75 | 2.4 |  |  |\n| 21 | 80 | 3.2 |  |  |\n| 23 | 85 | 3.2 |  |  |\n| Large Dog |  |  |  |  |\n| 25-30 | 80-90 | 4-6 |  |  |\n\nAbdomen – VD/DV view  \n\n| Thickness\u003Cbr>(cm) | Suggested\u003Cbr>kV | Suggested\u003Cbr>mAs | Adjusted\u003Cbr>kV | Adjusted\u003Cbr>mAs |\n| --- | --- | --- | --- | --- |\n| Cat/Small Dog |  |  |  |  |\n| 4-6 | 52 | 2.4 |  |  |\n| 8 | 52 | 3.2 |  |  |\n| 10 | 55 | 3.2 |  |  |\n| 12 | 55 | 4.5 |  |  |\n| 14 | 60 | 5 |  |  |\n| 16 | 65 | 6 |  |  |\n| Medium Dog |  |  |  |  |\n| 18 | 70 | 7 |  |  |\n| 20 | 75 | 7 |  |  |\n| 22 | 80 | 8 |  |  |\n| Large Dog |  |  |  |  |\n| 24-30 | 80 | 8-12 |  |  |\n\nContact us now   [www.](www.imv-imaging.co.uk)[imv-imaging](www.imv-imaging.co.uk)[.co.uk](www.imv-imaging.co.uk)  info@imv-imaging.com  +44 (0) 1506 460023  facebook.com/IMVimaging  twitter/IMVimaging  \nYour complete animal imaging solution  \nSmall animal exposure chart Computerised Radiography systems (CR)  \nSuggested exposures are for a Focal Spot/Film Distance (FFD) of 100cm without a grid If using a grid double the mAs or add 10kV  \nPelvis/Hips – lateral view  \n\n| Thickness\u003Cbr>(cm) | Suggested\u003Cbr>kV | Suggested\u003Cbr>mAs | Adjusted\u003Cbr>kV | Adjusted\u003Cbr>mAs |\n| --- | --- | --- | --- | --- |\n| Cat/Small Dog |  |  |  |  |\n| 8 | 55 | 3.2 |  |  |\n| 10 | 58 | 3.2 |  |  |\n| 12 | 60 | 4 |  |  |\n| 14 | 65 | 4 |  |  |\n| 16 | 65 | 5 |  |  |\n| Medium Dog |  |  |  |  |\n| 18 | 65 | 6.4 |  |  |\n| 20-22 | 65 | 8 |  |  |\n| Large Dog |  |  |  |  |\n| 24-30 | 70 | 10-16 |  |  |\n\nExtremities – lateral and CC/DP views  \n\n| Thickness\u003Cbr>(cm) | Suggested\u003Cbr>kV | Suggested\u003Cbr>mAs | Adjusted\u003Cbr>kV | Adjusted\u003Cbr>mAs |\n| --- | --- | --- | --- | --- |\n| Cat/Small Dog |  |  |  |  |\n| 1 | 50 | 2 |  |  |\n| 2 | 52 | 2 |  |  |\n| 3 | 52 | 2.4 |  |  |\n| 4 | 55 | 2.4 |  |  |\n| 5 | 55 | 3 |  |  |\n| Medium Dog |  |  |  |  |\n| 6 | 55 | 3.2 |  |  |\n| 8 | 60 | 4 |  |  |\n| Large Dog |  |  |  |  |\n| 10 | 62 | 5 |  |  |\n| 12 | 60 | 6.4 |  |  |\n| 14-20 | 60 | 8-10 |  |  |\n\nPelvis/Hips – VD view  \n\n| Thickness\u003Cbr>(cm) | Suggested\u003Cbr>kV | Suggested\u003Cbr>mAs | Adjusted\u003Cbr>kV | Adjusted\u003Cbr>mAs |\n| --- | --- | --- | --- | --- |\n| Cat/Small Dog |  |  |  |  |\n| 8 | 55 | 3.2 |  |  |\n| 10 | 58 | 3.2 |  |  |\n| 12 | 60 | 4 |  |  |\n| 14 | 65 | 4 |  |  |\n| 16 | 65 | 5 |  |  |\n| Medium Dog |  |  |  |  |\n| 18 | 65 | 6.4 |  |  |\n| 20-22 | 65 | 8 |  |  |\n| Large Dog |  |  |  |  |\n| 24-30 | 70 | 10-16 |  |  |\n\nSkull – lateral and DV/VD views  \n\n| Thickness\u003Cbr>(cm) | Suggested\u003Cbr>kV | Suggested\u003Cbr>mAs | Adjusted\u003Cbr>kV | Adjusted\u003Cbr>mAs |\n| --- | --- | --- | --- | --- |\n| Cat/Small Dog |  |  |  |  |\n| 6-8 | 50 | 2.4 |  |  |\n| 10 | 55 | 3.2 |  | ","cbCaigewwU1uji0x","https://ap.wps.com/l/cbCaigewwU1uji0x","pdf",173093,"English","# Thorax - Lateral view\n# Thorax - VD/DV view\n# Abdomen - Lateral view\n# Abdomen - VD/DV view\n# Pelvis/Hips - Lateral view\n# Pelvis/Hips - VD view\n# Extremities - Lateral and CC/DP views\n# Skull - Lateral and DV/VD views\n# Thoracic Spine - Lateral view\n# Cervical Spine - Lateral and VD views\n# Thoracic Spine - VD view\n# Lumbar Spine - Lateral and VD view","[{\"question\":\"What are the assumptions for the suggested exposure settings in this chart?\",\"answer\":\"The suggested exposures are for a Focal Spot/Film Distance (FFD) of 100 cm and without a grid.\"},{\"question\":\"How should exposure be adjusted when a grid is used?\",\"answer\":\"When using a grid, double the mAs or add 10 kV to the suggested settings.\"},{\"question\":\"How are the exposure values organized for different patients and anatomy?\",\"answer\":\"Tables are separated by anatomical region and view (e.g., thorax, abdomen, pelvis/hips, spine) and list values by patient thickness for cat/small dog, medium dog, and large dog.\"}]","Small Animal Exposure Chart - Computerised Radiography (CR) - Suggested Exposures | PDF",1791853331]