[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-177774-105":53,"doc-detail-177774-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","six-degrees-resilient-stair-tread-and-risers-csi-guide-specification","Six Degrees - Resilient Stair Tread and Risers - CS I Guide Specification","","Guide specification formatted to CSI MasterFormat requirements for Section 09 65 13.23, Resilient Stair Tread and Risers. Defines scope of work including labor, materials, equipment, and related items such as adhesives and accessories, with explicit exclusions for substrate and other adjacent work. Establishes submittals, product data, samples, quality assurance qualifications, and delivery/storage/handling conditions. Specifies installation project conditions, temperature and humidity ranges, and warranty provisions for manufacturing defects and workmanship failures.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/six-degrees-resilient-stair-tread-and-risers-csi-guide-specification/177774/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/six-degrees-resilient-stair-tread-and-risers-csi-guide-specification/177774.png","ImageObject",442,249,{"name":88,"@type":89},"Stanley","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/vnd.openxmlformats-officedocument.wordprocessingml.document","2026-10-04","2026-09-02",true,{"@type":98,"interactionType":99,"userInteractionCount":8},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What work scope does Section 09 65 13.23 cover for resilient stair treads and risers?","Question",{"text":108,"@type":109},"It includes providing labor, materials, and equipment to complete the section’s work, including adhesives and accessories for installation, plus substrate preparation activities related to this section. It also lists specific related work that is excluded and assigned to other sections.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"Which industry standards are referenced for testing and specifications?",{"text":113,"@type":109},"The specification cites ASTM standards for radiant flux, smoke density, friction, stair tread requirements, durometer hardness, thickness, heat stability, chemical resistance, and moisture-related practices, along with NFPA 253/258 and CAN/ULC-S102.2 for relevant testing.",{"name":115,"@type":106,"acceptedAnswer":116},"What environmental conditions must be maintained during installation?",{"text":117,"@type":109},"Resilient flooring installation must occur after other finishing operations. Temperature must be maintained between 60°F and 85°F with ±10°F stability for at least 48 hours before, during, and until substantial completion, and relative humidity must remain between 35% and 65% RH while avoiding condensation from dew point.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},177774,1788329138,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":8,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":125,"read_time":76},2336477405376,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","This document is provided to assist in the preparation of a Project or Master Specification. It has been formatted in accordance with the Construction Specifications Institute (CSI)’s MasterFormat®. Ensure the latest publicized version of all product information for this specification, Six Degrees will not be liable for any damages arising out of the use of any information or specifications found in this document.\nNote To specifier: remove and amend sections as necessary.\nBEGINNING OF SECTION\nPART 1 – GENERAL\nSUMMARY\nSection includes but not limited to the following: Section 09 65 13.23 Resilient Stair Tread and Risers\nAttention is directed to the CONTRACT AND GENERAL CONDITIONS and all Sections within DIVISION 01 - GENERAL REQUIREMENTS which are hereby made a part of this Section of the Specifications.\nREFERENCES\nWork Included: Provide labor, materials and equipment necessary to complete the work of this Section, including but not limited to the following:\nSection 09 65 13.23 Resilient Stair Tread and Risers\nAdhesives and accessories required for installation\nSubstrate preparation\nRelated Work: The following items are not included in this Section and are specified under the designated Sections:\nSection 03 30 00 CAST-IN-PLACE CONCRETE for concrete substrate; slab surface tolerances\nSection 06 10 00 ROUGH CARPENTRY for plywood substrate and surface tolerances\nSection 09 01 60 MAINTENANCE OF FLOORING for resilient floor covering care and upkeep\nSection 09 69 00 ACCESS FLOORING for resilient floor covering for access panels\nReferences (Industry Standards):\nASTM International (ASTM):\nASTM E648 - Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source\nASTM E662 - Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials\nASTM D2047 -  Standard Test Method for Static Coefficient of Friction of Polish-Coated Flooring Surfaces as Measured by the James Machine\nASTM F2169 - Standard Specification for Resilient Stair Treads\nASTM D2240 - Standard Test Method for Rubber Property – Durometer Hardness\nASTM F386 - Standard Test Method for Thickness of Resilient Flooring Materials Having Flat Surfaces\nASTM F1514 - Standard Test Method for Measuring Heat Stability of Resilient Flooring by Color Change\nASTM F925 - Standard Test Method for Resistance to Chemicals of Resilient Flooring\nASTM E1745 - Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs\nASTM F710 - Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring\nASTM F1482 - Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring\nASTM F2170 - Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes\nASTM F1869 - Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride\nASTM F3191 - Standard Practice for Field Determination of Substrate Water Absorption (Porosity) for Substrates to Receive Resilient Flooring\nASTM F3441 - Standard Guide for Measurement of pH Involving Resilient Flooring Installations\nASTM F3311 - Standard Practice for Mat Bond Evaluation of Performance and Compatibility for Resilient Flooring System Components Prior to Installation\nNational Fire Protection Association (NFPA):\nNFPA 253 - Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Energy Source\nNFPA 258 - Test Method for Specific Density of Smoke Generated by Solid Materials\nCanadian Standards (CAN):\nCAN/ULC-S102.2 - Test Method for Surface Burning of Materials\nSUBMITTALS\nGeneral: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures.\nProduct Data: Submit manufacturer's technical data sheet, care & maintenance document, submittal and/or warranty for each material and accessory proposed for use.\nSamples: Submit representat","cbCaiiL2ROdKhc4F","https://ap.wps.com/l/cbCaiiL2ROdKhc4F","docx",20964,9,"English","# Part 1 - General\n## Summary\n## References\n## Submittals\n## Quality Assurance\n## Delivery, Storage, and Handling\n## Project Conditions\n## Warranty","[{\"question\":\"What work scope does Section 09 65 13.23 cover for resilient stair treads and risers?\",\"answer\":\"It includes providing labor, materials, and equipment to complete the section’s work, including adhesives and accessories for installation, plus substrate preparation activities related to this section. It also lists specific related work that is excluded and assigned to other sections.\"},{\"question\":\"Which industry standards are referenced for testing and specifications?\",\"answer\":\"The specification cites ASTM standards for radiant flux, smoke density, friction, stair tread requirements, durometer hardness, thickness, heat stability, chemical resistance, and moisture-related practices, along with NFPA 253/258 and CAN/ULC-S102.2 for relevant testing.\"},{\"question\":\"What environmental conditions must be maintained during installation?\",\"answer\":\"Resilient flooring installation must occur after other finishing operations. Temperature must be maintained between 60°F and 85°F with ±10°F stability for at least 48 hours before, during, and until substantial completion, and relative humidity must remain between 35% and 65% RH while avoiding condensation from dew point.\"}]","Six Degrees - Resilient Stair Tread and Risers - CS I Guide Specification | DOCX"]