[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-562610-105":53,"doc-detail-562610-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","service-manual-for-remote-low-side-modular-flaked-and-nugget-ice-machines-prodigy-plus-d-series-models-f1222l-f1322l-n0922l-and-n1322l","Service Manual for Remote Low Side Modular Flaked and Nugget Ice Machines - Prodigy Plus D Series Models F1222L, F1322L, N0922L and N1322L","","Service manual covering remote low side modular flaked and nugget ice machines, including Prodigy Plus D Series models F1222L, F1322L, N0922L, and N1322L. Provides installation guidance and service navigation through components, electrical and water systems, sequence of operation, and diagnostic/repair procedures. Defines operational limits for air and water temperatures, potable water pressure, voltage ranges, minimum RO water conductivity, and water quality impacts on cleaning intervals and product life. Includes warranty scope and recommendations for filtration, chlorine removal considerations, and contamination risks.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/service-manual-for-remote-low-side-modular-flaked-and-nugget-ice-machines-prodigy-plus-d-series-models-f1222l-f1322l-n0922l-and-n1322l/562610/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/service-manual-for-remote-low-side-modular-flaked-and-nugget-ice-machines-prodigy-plus-d-series-models-f1222l-f1322l-n0922l-and-n1322l/562610.png","ImageObject",442,249,{"name":88,"@type":89},"pop out","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-25","2026-10-12",true,{"@type":98,"interactionType":99,"userInteractionCount":76},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What environmental limits must be followed to avoid voiding the warranty?","Question",{"text":108,"@type":109},"The manual specifies indoor use within controlled limits. It lists air temperature limits for the ice maker (50°F minimum, 100°F maximum), water temperature limits (40°F to 100°F), potable water pressure (20 to 80 psi), and voltage limits for 115 volt power (104 to 126).","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"How does water quality affect cleaning frequency and product life?",{"text":113,"@type":109},"Water impurities impact the interval between cleanings and ultimately the product’s lifespan. Suspended solids can be filtered, while dissolved solids require dilution or treatment, and filters are recommended to remove suspended solids.",{"name":115,"@type":106,"acceptedAnswer":116},"What guidance is given for chlorine removal and airborne contamination risks?",{"text":117,"@type":109},"Most water filters remove chlorine, which can affect contamination behavior. Testing indicates using a filter that does not remove chlorine, such as Scotsman Aqua Patrol, improves the situation. Installing near yeast or similar materials may require more frequent sanitation cleanings due to airborne contamination.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},562610,1792628295,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":76,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":15},962090760408,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","Service Manual for Remote Low Side Modular Flaked and Nugget Ice Machines including Prodigy Plus D Series Models F1222L, F1322L, N0922L and N1322L  \nThis ice machine is the result of years of experience The features include simple conductivity water level with flaked and nugget ice machines. The latest in sensing, evaporator clearing at shut down, photo-eye electronics has been coupled with the time tested sensing bin control and the ability to add options. Scotsman flaked ice system to provide reliable ice  \nmaking and the features needed by customers. Contents Installation: ..................................................................... Page 3  \nLocation: ....................................................................... Page 4  \nCabinet Layout .................................................................. Page 5  \nUnpacking ...................................................................... Page 6  \nWater .......................................................................... Page 7  \nElectrical ....................................................................... Page 8  \nRefrigeration .................................................................... Page 9  \nFinal Check List .................................................................. Page 10  \nInitial Start Up ................................................................... Page 11  \nController ....................................................................... Page 12  \nAutoAlert and Display Code ........................................................ Page 13  \nComponent Indicator Lights......................................................... Page 14  \nElectrical Component Details ....................................................... Page 15  \nSequence of Operation ............................................................ Page 16  \nElectrical Sequence with Condensing Unit ............................................. Page 17  \nWater System ................................................................... Page 18  \nRemote Refrigeration with Condensing Unit ............................................ Page 19  \nHow Ice Is Made ................................................................. Page 20  \nScale removal ................................................................... Page 21  \nCheck Top Bearing ............................................................... Page 22  \nBearing Service .................................................................. Page 23  \nOptions ........................................................................ Page 24  \nService Diagnosis ................................................................ Page 25  \nService Diagnosis-Optional Ice Level Controls ......................................... Page 26  \nRepair Procedures: Bearing And Breaker .............................................. Page 27  \nRepair Procedures: The Auger ...................................................... Page 28  \nAuger and Evaporator Inspection .................................................... Page 29  \nRepair Procedures: The Water Seal:.................................................. Page 30  \nRepair Procedures: Replace the Evaporator: ........................................... Page 31  \nRepair Procedures: The gear reducer ................................................. Page 32  \nRepair Procedures: Thermostatic Expansion Valve ...................................... Page 33  \nDecember 2014  \nThis machine is designed to be used indoors, in a controlled environment. Operation outside the limits listed here will void the warranty.  \nAir temperature limits  \n\n|  | Minimum | Maximum |\n| --- | --- | --- |\n| Ice maker | 50oF. | 100oF. |\n\nWater temperature limits  \n\n|  | Minimum | Maximum |\n| --- | --- | --- |\n| All models | 40oF. | 100oF. |\n\nWater pressure limits (potable)  \n\n|  | Minimum | Maximum |\n| --- | --- | --- |\n| All models | 20 psi | 80 psi |\n\nVoltage limits  \n\n|  | Minimum | Maximum |\n| ---","cbCaifmv4lyt4jrw","https://ap.wps.com/l/cbCaifmv4lyt4jrw","pdf",4899709,34,"English","# Installation\n## Location\n## Cabinet Layout\n## Unpacking\n## Water\n## Electrical\n## Refrigeration\n## Final Check List\n## Initial Start Up\n## Controller\n## AutoAlert and Display Code\n## Component Indicator Lights\n## Electrical Component Details\n## Sequence of Operation\n## Electrical Sequence with Condensing Unit\n## Water System\n## Remote Refrigeration with Condensing Unit\n## How Ice Is Made\n## Scale Removal\n## Check Top Bearing\n## Bearing Service\n## Options\n## Service Diagnosis\n## Service Diagnosis - Optional Ice Level Controls\n# Repair Procedures\n## Bearing And Breaker\n## The Auger\n## Auger and Evaporator Inspection\n## The Water Seal\n## Replace the Evaporator\n## The Gear Reducer\n## Thermostatic Expansion Valve","[{\"question\":\"What environmental limits must be followed to avoid voiding the warranty?\",\"answer\":\"The manual specifies indoor use within controlled limits. It lists air temperature limits for the ice maker (50°F minimum, 100°F maximum), water temperature limits (40°F to 100°F), potable water pressure (20 to 80 psi), and voltage limits for 115 volt power (104 to 126).\"},{\"question\":\"How does water quality affect cleaning frequency and product life?\",\"answer\":\"Water impurities impact the interval between cleanings and ultimately the product’s lifespan. Suspended solids can be filtered, while dissolved solids require dilution or treatment, and filters are recommended to remove suspended solids.\"},{\"question\":\"What guidance is given for chlorine removal and airborne contamination risks?\",\"answer\":\"Most water filters remove chlorine, which can affect contamination behavior. Testing indicates using a filter that does not remove chlorine, such as Scotsman Aqua Patrol, improves the situation. Installing near yeast or similar materials may require more frequent sanitation cleanings due to airborne contamination.\"}]","Service Manual for Remote Low Side Modular Flaked and Nugget Ice Machines - Prodigy Plus D Series Models F1222L, F1322L, N0922L and N1322L | PDF",1791809087]