[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-177775-105":53,"doc-detail-177775-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","rubber-stair-tread-with-riser-section-general","Rubber Stair Tread with Riser  - SECTION - GENERAL","","Suggested guide for creating and editing CSI formatted 3-part architectural guide specifications for resilient rubber stair treads with risers. Includes sections covering related documents and section summary, required submittals (product data, LEED VOC statements for adhesives, initial selection samples, verification samples, and product schedule), and quality assurance via specified mockups. Defines delivery, storage, and handling conditions, installation timing relative to other finishes, and project ambient temperature/humidity requirements. Specifies Johnsonite integrated stair tread and riser material composition, ASTM standards, accessibility inserts, and color/pattern/length selection instructions.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":46,"@type":70,"position":76},"https://docshare.wps.com/template/paper-templates/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/rubber-stair-tread-with-riser-section-general/177775/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/rubber-stair-tread-with-riser-section-general/177775.png","ImageObject",442,249,{"name":88,"@type":89},"Logic","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/octet-stream","2026-09-29","2026-09-02",true,{"@type":98,"interactionType":99,"userInteractionCount":76},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What product is covered in this specification section?","Question",{"text":108,"@type":109},"Resilient rubber stair tread with riser, including Johnsonite rubber integrated stair tread and riser with defined physical characteristics.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"What submittals are required?",{"text":113,"@type":109},"Provide product data for each product type, LEED submittals for Credit EQ 4.1 with adhesive VOC content and chemical components, samples for initial selection and verification, and a product schedule for resilient products using the same designations as the drawings.",{"name":115,"@type":106,"acceptedAnswer":116},"What installation environmental conditions must be maintained?",{"text":117,"@type":109},"Maintain recommended ambient temperature ranges during the specified periods (48 hours before installation, during installation, and 48 hours after), keep relative humidity between 40% and 60% during installation, and follow continued temperature requirements until Substantial Completion.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},177775,1790634895,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":45,"category_name":46,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":76,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":8,"language":135,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":136,"faqs":137,"seo_title":138,"seo_description":61,"update_tm":139,"read_time":79},1099513958762,"https://ap-avatar.wpscdn.com/avatar/1000023916a998db790?x-image-process=image/resize,m_fixed,w_180,h_180&k=1784791008015729253","This document is intended as a suggested guide for creating, modifying, or editing your CSI Formatted 3-Part Architectural Guide Specifications.\nJohnsonite will not be liable for any damages arising out of the use of any information or specifications found in this document.\nEnsure that you have the latest publication for this specification.\nThe specifier or designer is responsible for product selection and accuracy of all project specifications, including any Johnsonite information or specifications used.\nGENERAL\nRELATED DOCUMENTS\nDrawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.\nSUMMARY\nSection Includes:\nResilient Rubber Stair Tread with Riser.\nSUBMITTALS\nProduct Data:  For each type of product indicated.\nLEED Submittals:\nProduct Data for Credit EQ 4.1:  For adhesives, including printed statement of VOC content and chemical components.\nSamples for Initial Selection:  For each type of product indicated.\nSamples for Verification:  For each type of product indicated, in manufacturer's standard-size samples of each resilient product color, texture, and pattern required.\nProduct Schedule:  For resilient products. Use same designations indicated on Drawings.\nQUALITY ASSURANCE\nMockups:  Provide resilient products with mockups specified in other Sections.\nDELIVERY, STORAGE, AND HANDLING\nStore resilient products and installation materials in dry spaces protected from the weather, with ambient temperatures maintained within range recommended by Johnsonite, but not less than 55 deg F (13 deg C) or more than 85 deg F (29 deg C).\nPROJECT CONDITIONS\nInstall resilient products after other finishing operations, including painting, have been completed.\nMaintain ambient temperatures within range recommended by Johnsonite, but not less than 65 deg F (18 deg C) or more than 85 deg F (29 deg C) in spaces to receive resilient products during the following time periods:\n48 hours before installation.\nDuring installation.\n48 hours after installation.\nMaintain the ambient relative humidity between 40% and 60% during installation.\nUntil Substantial Completion, maintain ambient temperatures within range recommended by Johnsonite, but not less than 55 deg F (13 deg C) or more than 85 deg F (29 deg C).\n\u000fPRODUCTS\nRESILIENT RUBBER STAIR TREAD WITH RISER\nResilient Rubber Stair Tread:\nJOHNSONITE RUBBER INTEGRATED STAIR TREAD WITH RISER specify – Rubber\nIntegrated Stair Tread and Riser with the following physical characteristics:\nManufactured from a homogeneous composition of 100% synthetic rubber.\nComplies with requirements for ASTM F 2169 Standard Specification for Resilient Stair Treads, Type TS, Class 1 and 2, Group 1 and 2.\nHardness: ASTM D 2240 – Not less than 85 Shore A.\nAbrasion Resistance: ASTM D 3389 – less than 1 gram weight loss.\nASTM D 2047, Standard Test Method for Static Coefficient of Friction of Polish- Coated Flooring of 0.6 or greater.\nASTM E 648, Standard Test Method for Critical Radiant Flux of 0.45 watts/cm2 or greater, Class I.\nIntegrated tread and riser.\nVisually  Impaired  treads  meet  ADA  and  are  California  Title  24  Accessibility requirements.\nVisually Impaired treads will have 2\" wide co-extruded contrasting color insert or 2\" wide contrasting color grit tape insert.\nSolid Color Rubber Integrated Stair Tread and Riser\nFor Raised Round surface, solid color integrated stair tread and riser, 2\" height hinged Square Nose, tapering .210\" to .113\", 20\" overall width including 13\" tread depth with 7\" integrated riser, tread length 3', 3.5', 4', 4.5', 5', 6', 7', 8' or 9'\nSpecify (RTR –\nSpecify color by number and name\t–\no\tSpecify length [3', 3.5', 4', 4.5', 5', 6', 7', 8' or 9']\t–\nSpecify 'Round Pattern')\nFor Raised Square surface, solid color integrated stair tread and riser, 2\" height hinged Square Nose, tapering .210\" to .113\", 20\" overall width including 13\" tread depth with 7\" integrated riser, tread length 3', 3.5', 4', ","cbCaivpjzImGXsLH","https://ap.wps.com/l/cbCaivpjzImGXsLH","doc",227840,"English","# Related Documents\n# Summary\n## Section Includes\n# Submittals\n# Quality Assurance\n# Delivery, Storage, and Handling\n# Project Conditions\n# Products\n## Resilient Rubber Stair Tread with Riser","[{\"question\":\"What product is covered in this specification section?\",\"answer\":\"Resilient rubber stair tread with riser, including Johnsonite rubber integrated stair tread and riser with defined physical characteristics.\"},{\"question\":\"What submittals are required?\",\"answer\":\"Provide product data for each product type, LEED submittals for Credit EQ 4.1 with adhesive VOC content and chemical components, samples for initial selection and verification, and a product schedule for resilient products using the same designations as the drawings.\"},{\"question\":\"What installation environmental conditions must be maintained?\",\"answer\":\"Maintain recommended ambient temperature ranges during the specified periods (48 hours before installation, during installation, and 48 hours after), keep relative humidity between 40% and 60% during installation, and follow continued temperature requirements until Substantial Completion.\"}]","Rubber Stair Tread with Riser  - SECTION - GENERAL | DOC",1788329138]