[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-565301-105":53,"doc-detail-565301-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","refrigerants-lubricants-refrigerant-property-summary","REFRIGERANTS & LUBRICANTS - Refrigerant Property Summary","","REFRIGERANTS & LUBRICANTS summarizes refrigerant properties for multiple ASHRAE refrigerants, listing safety ratings, composition by weight where available, and temperature glide with recommended lubricant compatibility. The content groups refrigerants by application ranges, including very low temperature and cascade systems, low-medium temperature refrigeration, low-medium temperature refrigeration (R-12 type), medium-high temperature refrigeration, air conditioning (R-22 type), and high ambient/centrifugal chillers. It also provides narrative guidance for specific retrofit blends (e.g., R-401A, R-401B, R-409A) describing pressures, capacity matching conditions, temperature glides, and lubrication miscibility considerations.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/refrigerants-lubricants-refrigerant-property-summary/565301/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/refrigerants-lubricants-refrigerant-property-summary/565301.png","ImageObject",442,249,{"name":88,"@type":89},"RuangKosong","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-31","2026-10-13",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",8,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What information is included in the refrigerant property summary table?","Question",{"text":109,"@type":110},"The table lists refrigerant identification (including ASHRAE/Trade Name), component weights when provided, ASHRAE safety ratings, temperature glide, and associated lubricant and comments for usage and compatibility.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"How does the document organize refrigerants for selection?",{"text":114,"@type":110},"Refrigerants are grouped by operating application ranges and system types, such as very low temperature and cascade refrigeration, low-medium temperature refrigeration, air conditioning (R-22 type), and high ambient/centrifugal chillers.",{"name":116,"@type":107,"acceptedAnswer":117},"What practical guidance is given for retrofit blends like R-401A and R-401B?",{"text":118,"@type":110},"For R-401A and R-401B, the document explains how pressure and system capacity can match R-12 within specific evaporator temperature ranges, notes typical temperature glide, and highlights oil/lubricant miscibility concerns and when some oil changes are recommended.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},565301,1792085816,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":136,"language":137,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":138,"faqs":139,"seo_title":140,"seo_description":61,"update_tm":141,"read_time":142},962090883219,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","REFRIGERANTS & LUBRICANTS  \n536  CUSTOMER SERVICE CENTER ... 888-578-9100  \nPage  \n• Refrigerants   538-551  \n• Testing   552-553  \n• Refrigerant Labels   553  \n• Oil   554-560  \n• Lubricant Cross Reference   555-557  \nTABLE OF CONTENTS  \nREFRIGERANTS & LUBRICANTS  \n537  \nREFRIGERANTS & LUBRICANTS  \nREFRIGERANT PROPERTY SUMMARY   \n\n| ASHRAE No.\u003Cbr>(Trade Name) | Components\u003Cbr>(Weight %) | ASHRAE Safety\u003Cbr>Rating |  | Temperature\u003Cbr>Glide (°F) Lubricants Comments |  |\n| --- | --- | --- | --- | --- | --- |\n| Very Low Temperature and Cascade Refrigeration (R-13 and R-503 Type) |  |  |  |  |  |\n| R-23 100 A1 0 POLYOLESTER Properties similar to R-13;\u003Cbr>runs hotter on discharge side. |  |  |  |  |  |\n| R-508B 23/116\u003Cbr>(46/54) |  | A1 0 POLYOLESTER Properties similar to R-503;\u003Cbr>can be used for both types. |  |  |  |\n| R-403B 290/22/218\u003Cbr>(5/56/39) |  | A1 2.5 MINERAL OIL or Has been used successfully\u003Cbr>ALKYLBENZENE in 13B1 type equipment. |  |  |  |\n| Low-Medium Temperature Refrigeration (R-502 Type) |  |  |  |  |  |\n| R-22 100 A1 0 MINERAL OIL or\u003Cbr>ALKYLBENZENE |  |  |  |  | Equipment typically uses liquid injection cooling (high dis. T) |\n| R-402A 125/290/22\u003Cbr>(60/2/38) |  | A1 2.5 ALKYLBENZENE\u003Cbr>OR MO/AB MIX |  |  | Retrofit blend; higher discharge pressure than 502. |\n| R-402B 125/290/22\u003Cbr>(38/2/60) |  | A1 2.5 ALKYLBENZENE\u003Cbr>OR MO/AB MIX |  |  | Retrofit blend for ice mach.; higher discharge temp. |\n| R-404A 125/143a/134a\u003Cbr>(44/52/4) |  | A1 1.5 POLYOLESTER HFC blend-long term new or\u003Cbr>retrofit (oil flush required) . |  |  |  |\n| R-408A 125/143a/22\u003Cbr>(7/46/47) |  | A1 1 MINERAL OIL or\u003Cbr>ALKYLBENZENE |  |  | Retrofit blend; slightly higher discharge temp. |\n| R-422C 125/134a/600a\u003Cbr>(82/15/3) |  | A1 5 MINERAL OIL or\u003Cbr>ALKYLBENZENE, POE |  |  | HFC blend similar to R422A |\n| R-448A 32/125/1234yf/134a/1234ze\u003Cbr>(26/26/20/21/7) |  |  | A1 7 POLYOLESTER Low GWP alternative to R-404A and R-507 |  |  |\n| R-452A 32/125/1234yf\u003Cbr>(11/59/30) |  | A1 5.4 Low GWP alternative to R-404A and R-507 |  |  |  |\n| R-507 125/143a\u003Cbr>(50/50) |  | A1 0 POLYOLESTER HFC blend, azeotrope,\u003Cbr>higher discharge pressure. |  |  |  |\n| Low Medium Temperature Refrigeration (R-22 Type) |  |  |  |  |  |\n| R-407A 32/125/134a\u003Cbr>(20/40/40) |  | A1 8 POLYOLESTER Similar efficiency and capacity to R-22 |  |  |  |\n| R-407F 32/125/134a\u003Cbr>(30/30/40) |  | A1 10 POLYOLESTER Similar efficiency and capacity to R-22 |  |  |  |\n| R-422D 125/134a/600a\u003Cbr>(65.1/31.5/3.4) |  | A1 5 MINERAL OIL or\u003Cbr>ALKYLBENZENE, POE |  |  | It can replace R22 with existing oil in system |\n| R-290 100 A3 0 MINERAL OIL New equipment only-designed to safely\u003Cbr>use hydrocarbon refrigerant |  |  |  |  |  |\n| Low-Medium Temperature Refrigeration (R-12 Type) |  |  |  |  |  |\n| R-22 100 A1 0 MINERAL OIL or\u003Cbr>ALKYLBENZENE |  |  |  |  | New systems (retrofit involves equipment changes) . |\n| R-134a 100 A1 0 POLYOLESTER HFC-new systems. Retrofit\u003Cbr>involves oil flushing. |  |  |  |  |  |\n| R-401A 22/152a/124\u003Cbr>(53/13/34) |  | A1 8 ALKYLBENZENE\u003Cbr>OR MO/AB MIX |  |  | Retrofit blend; higher glide and discharge pressure/temp. |\n| R-401B 22/152a/124\u003Cbr>(61/11/28) |  | A1 8 ALKYLBENZENE\u003Cbr>OR MO/AB MIX |  |  | Lower temp. retrofit blend (boost to capacity >-20F) |\n| R-409A 22/124/142b\u003Cbr>(60/25/15) |  | A1 12 MINERAL OIL or\u003Cbr>ALKYLBENZENE |  |  | Retrofit blend; higher glide and discharge pressure/temp. |\n| R-417C 125/134a/600\u003Cbr>(19.5/78.8/1.7) |  | A1 6 MINERAL OIL or\u003Cbr>ALKYLBENZENE, POE |  |  | HFC retrofit blend with HC oil additive |\n| Medium-High Temperature Refrigeration (R-12 Type) |  |  |  |  |  |\n| R-1234yf 100 A2L 0 POLYOLESTER Low GWP; automotive AC and other 134a\u003Cbr>applications |  |  |  |  |  |\n| R-1234ze 100 A2L 0 POLYOLESTER Low GWP; chillers and other 134\u003Cbr>applications |  |  |  |  |  |\n| R-414B 22/600a/124/142b\u003Cbr>(50/1.5/39/9.5) |  | A1 12 MINERAL OIL or\u003Cbr>ALKYLBENZENE |  |  | \"Automotive\" type blends which can be used for refrigeration. Typically match R-12 in con","cbCairlZbTfHdtbG","https://ap.wps.com/l/cbCairlZbTfHdtbG","pdf",3260607,25,"English","# Refrigerants & Lubricants\n## Refrigerant Property Summary","[{\"question\":\"What information is included in the refrigerant property summary table?\",\"answer\":\"The table lists refrigerant identification (including ASHRAE/Trade Name), component weights when provided, ASHRAE safety ratings, temperature glide, and associated lubricant and comments for usage and compatibility.\"},{\"question\":\"How does the document organize refrigerants for selection?\",\"answer\":\"Refrigerants are grouped by operating application ranges and system types, such as very low temperature and cascade refrigeration, low-medium temperature refrigeration, air conditioning (R-22 type), and high ambient/centrifugal chillers.\"},{\"question\":\"What practical guidance is given for retrofit blends like R-401A and R-401B?\",\"answer\":\"For R-401A and R-401B, the document explains how pressure and system capacity can match R-12 within specific evaporator temperature ranges, notes typical temperature glide, and highlights oil/lubricant miscibility concerns and when some oil changes are recommended.\"}]","REFRIGERANTS & LUBRICANTS - Refrigerant Property Summary | PDF",1791850887,9]