[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-563335-105":3,"detail-sidebar-cat-1-en-105":81,"doc-detail-563335-en":127},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","r-410a-pressure-temperature-chart","R-410A Pressure-temperature chart","","R-410A Pressure-temperature chart provides a lookup table linking refrigerant pressure (PSIG) to corresponding temperature (°F) values. The chart lists multiple pressure points from sub-zero temperatures up through higher ranges, presented in a compact multi-column format for quick reference. It is sourced from the Bonneville Power Authority and referenced for R-410A refrigerant system use where pressure and temperature correlation is needed. Values are organized to support efficient selection or verification of conditions during troubleshooting or performance checks.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/general/","General",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/r-410a-pressure-temperature-chart/563335/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/r-410a-pressure-temperature-chart/563335.png","ImageObject",442,249,{"name":42,"@type":43},"Stanley","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-02","2026-10-12",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What does the R-410A pressure-temperature chart map?","Question",{"text":63,"@type":64},"It maps refrigerant pressure measured in PSIG to temperature measured in °F for R-410A.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How should I read the chart?",{"text":68,"@type":64},"Find a PSIG value in the table, then read across to get the corresponding °F temperature.",{"name":70,"@type":61,"acceptedAnswer":71},"Where is this chart attributed to?",{"text":72,"@type":64},"The chart text states it was provided by the Bonneville Power Authority.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},563335,1792086973,{"code":4,"msg":82,"data":83},"success",[84,89,94,99,104,109,114,119,124],{"id":85,"doc_module":22,"doc_module_name":25,"category_name":86,"show_sort_weight":87,"slug":88},11,"Presentations",90,"presentations",{"id":90,"doc_module":22,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},12,"Resumes",80,"resumes",{"id":95,"doc_module":22,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},14,"Invoices",70,"invoices",{"id":100,"doc_module":22,"doc_module_name":25,"category_name":101,"show_sort_weight":102,"slug":103},15,"Posters",60,"posters",{"id":105,"doc_module":22,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},16,"Social Media",50,"social-media",{"id":110,"doc_module":22,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},17,"Forms",40,"forms",{"id":115,"doc_module":22,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},18,"Letters",30,"letters",{"id":120,"doc_module":22,"doc_module_name":25,"category_name":121,"show_sort_weight":122,"slug":123},21,"Paper Templates",5,"papers-templates",{"id":125,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":4,"slug":126},158,"general-158",{"code":4,"msg":82,"data":128},{"doc_id":79,"user_id":129,"nickname":42,"user_avatar":130,"doc_module":22,"category_id":125,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":136,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":12,"update_tm":140,"read_time":4},2336477405376,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","CLICK ANYWHERE on THIS PAGE to return [to R410A REFRIGERANT PRESSURE / TEMPERATURE CHARTS at InspectApedia.com](to R410A REFRIGERANT PRESSURE / TEMPERATURE CHARTS at InspectApedia.com)  \nThis chart was provided by the Bonneville Power Authority,  \n[http://www.bpa.gov/energy/n/residential/ptcs/R-410A_Pressure_Temperature_Chart.pdf](http://www.bpa.gov/energy/n/residential/ptcs/R-410A_Pressure_Temperature_Chart.pdf)  \nR-410A Pressure-temperature chart  \n\n| PSIG | °F | PSIG | °F | PSIG | °F | PSIG | °F | PSIG | °F | PSIG | °F |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 12 | –37.7 | 114 | 37.8 | 216 | 74.3 | 318 | 100.2 | 420 | 120.7 | 522 | 137.6 |\n| 14 | –34.7 | 116 | 38.7 | 218 | 74.9 | 320 | 100.7 | 422 | 121 | 524 | 137.9 |\n| 16 | –32.0 | 118 | 39.5 | 220 | 75.5 | 322 | 101.1 | 424 | 121.4 | 526 | 138.3 |\n| 18 | –29.4 | 120 | 40.5 | 222 | 76.1 | 324 | 101.6 | 426 | 121.7 | 528 | 138.6 |\n| 20 | –36.9 | 122 | 41.3 | 224 | 76.7 | 326 | 102 | 428 | 122.1 | 530 | 138.9 |\n| 22 | –24.5 | 124 | 42.2 | 226 | 77.2 | 328 | 102.4 | 430 | 122.5 | 532 | 139.2 |\n| 24 | –22.2 | 126 | 43 | 228 | 77.8 | 330 | 102.9 | 432 | 122.8 | 534 | 139.5 |\n| 26 | –20.0 | 128 | 43.8 | 230 | 78.4 | 332 | 103.3 | 434 | 123.2 | 536 | 139.8 |\n| 28 | –17.9 | 130 | 44.7 | 232 | 78.9 | 334 | 103.7 | 436 | 123.5 | 538 | 140.1 |\n| 30 | –15.8 | 132 | 45.5 | 234 | 79.5 | 336 | 104.2 | 438 | 123.9 | 540 | 140.4 |\n| 32 | –13.8 | 134 | 46.3 | 236 | 80 | 338 | 104.6 | 440 | 124.2 | 544 | 141 |\n| 34 | –11.9 | 136 | 47.1 | 238 | 80.6 | 340 | 105.1 | 442 | 124.6 | 548 | 141.6 |\n| 36 | –10.1 | 138 | 47.9 | 240 | 81.1 | 342 | 105.4 | 444 | 124.9 | 552 | 142.1 |\n| 38 | –8.3 | 140 | 48.7 | 242 | 81.6 | 344 | 105.8 | 446 | 125.3 | 556 | 142.7 |\n| 40 | –6.5 | 142 | 49.5 | 244 | 82.2 | 346 | 106.3 | 448 | 125.6 | 560 | 143.3 |\n| 42 | –4.5 | 144 | 50.3 | 246 | 82.7 | 348 | 106.6 | 450 | 126 | 564 | 143.9 |\n| 44 | –3.2 | 146 | 51.1 | 248 | 83.3 | 350 | 107.1 | 452 | 126.3 | 568 | 144.5 |\n| 46 | –1.6 | 148 | 51.8 | 250 | 83.8 | 352 | 107.5 | 454 | 126.6 | 572 | 145 |\n| 48 | 0 | 150 | 52.5 | 252 | 84.3 | 354 | 107.9 | 456 | 127 | 576 | 145.6 |\n| 50 | 1.5 | 152 | 53.3 | 254 | 84.8 | 356 | 108.3 | 458 | 127.3 | 580 | 146.2 |\n| 52 | 3 | 154 | 54 | 256 | 85.4 | 358 | 108.8 | 460 | 127.7 | 584 | 146.7 |\n| 54 | 4.5 | 156 | 54.8 | 258 | 85.9 | 360 | 109.2 | 462 | 128 | 588 | 147.3 |\n| 56 | 5.9 | 158 | 55.5 | 260 | 86.4 | 362 | 109.6 | 464 | 128.3 | 592 | 147.9 |\n| 58 | 7.3 | 160 | 56.2 | 262 | 86.9 | 364 | 110 | 466 | 128.7 | 596 | 148.4 |\n| 60 | 8.6 | 162 | 57 | 264 | 87.4 | 366 | 110.4 | 468 | 129 | 600 | 149 |\n| 62 | 10 | 164 | 57.7 | 266 | 87.9 | 368 | 110.8 | 470 | 129.3 | 604 | 149.5 |\n| 64 | 11.3 | 166 | 58.4 | 268 | 88.4 | 370 | 111.2 | 472 | 129.7 | 608 | 150.1 |\n| 66 | 12.6 | 168 | 59 | 270 | 88.9 | 372 | 111.6 | 474 | 130 | 612 | 150.6 |\n| 68 | 13.8 | 170 | 59.8 | 272 | 89.4 | 374 | 112 | 476 | 130.3 | 616 | 151.2 |\n| 70 | 15.1 | 172 | 60.5 | 274 | 89.9 | 376 | 112.4 | 478 | 130.7 | 620 | 151.7 |\n| 72 | 16.3 | 174 | 61.1 | 276 | 90.4 | 378 | 112.6 | 480 | 131 | 624 | 152.3 |\n| 74 | 17.5 | 176 | 61.8 | 278 | 90.9 | 380 | 113.1 | 482 | 131.3 | 628 | 152.8 |\n| 76 | 18.7 | 178 | 62.5 | 280 | 91.4 | 382 | 113.5 | 484 | 131.6 | 632 | 153.4 |\n| 78 | 19.8 | 180 | 63.1 | 282 | 91.9 | 384 | 113.9 | 486 | 132 | 636 | 153.9 |\n| 80 | 21 | 182 | 63.8 | 284 | 92.4 | 386 | 114.3 | 488 | 132.3 | 640 | 154.5 |\n| 82 | 22.1 | 184 | 64.5 | 286 | 92.8 | 388 | 114.7 | 490 | 132.6 | 644 | 155 |\n| 84 | 23.2 | 186 | 65.1 | 288 | 93.3 | 390 | 115 | 492 | 132.9 | 648 | 155.5 |\n| 86 | 24.3 | 188 | 65.8 | 290 | 93.8 | 392 | 115.5 | 494 | 133.3 | 652 | 156.1 |\n| 88 | 25.4 | 190 | 66.4 | 292 | 94.3 | 394 | 115.8 | 496 | 133.6 | 656 | 156.6 |\n| 90 | 26.4 | 192 | 67 | 294 | 94.8 | 396 | 116.2 | 498 | 133.9 | 660 | 157.1 |\n| 92 | 27.4 | 194 | 67.7 | 296 | 95.2 | 398 | 116.6 | 500 | 134 | 664 | 157.7 |\n| 94 | 28.5 | 196 | 68.3 | 298 | 95.7 | 400 | 117 | 502 | 134.5 | 668 | 158.2 |\n| ","cbCaiikl2z4T7n43","https://ap.wps.com/l/cbCaiikl2z4T7n43","pdf",117207,"English","# R-410A Pressure-temperature chart\n## Pressure (PSIG) to Temperature (°F) table","[{\"question\":\"What does the R-410A pressure-temperature chart map?\",\"answer\":\"It maps refrigerant pressure measured in PSIG to temperature measured in °F for R-410A.\"},{\"question\":\"How should I read the chart?\",\"answer\":\"Find a PSIG value in the table, then read across to get the corresponding °F temperature.\"},{\"question\":\"Where is this chart attributed to?\",\"answer\":\"The chart text states it was provided by the Bonneville Power Authority.\"}]","R-410A Pressure-temperature chart | PDF",1791829619]