[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-568541-105":3,"detail-sidebar-cat-1-en-105":81,"doc-detail-568541-en":127},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","r-134a-pressuretemperature-chart","R-134a - Pressure/Temperature Chart","","R-134a pressure/temperature chart providing conversion guidance between temperature (Fahrenheit and Celsius) and corresponding pressure values. The table lists multiple temperature points with associated pressures in psi/PSIG and kPa, covering evaporator (EVAPORATOR) and condenser (CONDENSER) ranges. The document also includes torque settings for ring fittings and related components, plus pressure switch installation torque specifications for Schrader and M10 ports, supporting correct assembly and servicing.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/general/","General",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/r-134a-pressuretemperature-chart/568541/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/r-134a-pressuretemperature-chart/568541.png","ImageObject",442,249,{"name":42,"@type":43},"awa","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29","2026-10-13",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What units does the R-134a pressure/temperature chart provide?","Question",{"text":63,"@type":64},"It provides pressure values in PSIG (psi gauge) and in kPa, mapped to Fahrenheit and Celsius temperature entries.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Does the chart cover both evaporator and condenser conditions?",{"text":68,"@type":64},"Yes. It includes labeled sections for EVAPORATOR (evaporator) and CONDENSER (condenser) ranges.",{"name":70,"@type":61,"acceptedAnswer":71},"Where are the torque settings listed?",{"text":72,"@type":64},"The document includes a dedicated “Torque Settings” section with values for ring fittings and installation items, including pressure switch port torque specifications.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},568541,1792040010,{"code":4,"msg":82,"data":83},"success",[84,89,94,99,104,109,114,119,124],{"id":85,"doc_module":22,"doc_module_name":25,"category_name":86,"show_sort_weight":87,"slug":88},11,"Presentations",90,"presentations",{"id":90,"doc_module":22,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},12,"Resumes",80,"resumes",{"id":95,"doc_module":22,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},14,"Invoices",70,"invoices",{"id":100,"doc_module":22,"doc_module_name":25,"category_name":101,"show_sort_weight":102,"slug":103},15,"Posters",60,"posters",{"id":105,"doc_module":22,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},16,"Social Media",50,"social-media",{"id":110,"doc_module":22,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},17,"Forms",40,"forms",{"id":115,"doc_module":22,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},18,"Letters",30,"letters",{"id":120,"doc_module":22,"doc_module_name":25,"category_name":121,"show_sort_weight":122,"slug":123},21,"Paper Templates",5,"papers-templates",{"id":125,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":4,"slug":126},158,"general-158",{"code":4,"msg":82,"data":128},{"doc_id":79,"user_id":129,"nickname":42,"user_avatar":130,"doc_module":22,"category_id":125,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":136,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":12,"update_tm":140,"read_time":22},3985747858093,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","R-134aFahrenheit  \nPSIG  \nPSIG  \nF  \n 16  \n  16   \n125  \n101  \n19  \n18  \n130  \n103  \n 20  \n 22  \n105  \n135  \nPressure/TemperatureChart  \n22  \n25  \n140  \n107  \n 24  \n  27   \n145  \n110  \n30  \n26  \n150  \n112  \nEVA  \n 28  \n  32   \n160  \n116  \nPORATOR  \n 34  \n30  \n170  \n120  \n 36  \n32  \n124  \n180  \nTorque Settings\\#60-Ring Fitting:11-13ft-lb\\#80-RingFitting:15-20ft-Ib\\#100-RingFitting:21-27 t-Ib\\#120-RingFitting:28-30ft-1b\\#140-Ring Fitting:30-35ft-bPressure switch on Schraderport (716-20):85-90 in-IbPressure switchon M10port:60-65 in-IbSchrader portvalve insert:3-5in-b  \n 34  \n 39  \n127  \n190  \n 36  \n  41   \n200  \n131  \n38  \n 44  \n210  \n134  \n 40  \n 48   \n137  \n220  \n 47  \n 42  \n230  \n141  \n44  \n 49   \n144  \n240  \n46  \n50  \n250  \n147  \nCOND  \n48  \n52  \n260  \n150  \n50  \n54  \n152  \n270  \nENSER  \n55  \n58  \n155  \n280  \n60  \n62  \n158  \n290  \n65  \n66  \n300  \n160  \n70  \n69  \n310  \n163  \n75  \n73  \n165  \n320  \n80  \n76  \n330  \n168  \n85  \n79  \n340  \n170  \n90  \n82  \n350  \n172  \n95  \n85  \n175  \n360  \n88  \n100  \n370  \n177  \n105  \n91  \n179  \n380  \n93  \n110  \n181  \n390  \n96  \n115  \n400  \n183  \n98  \n120  \n185  \n410  \nCopyright O2010 Red Dot Corporation  \nRD-5-13053-0P Rev-  \n# R-134a\n\nkPa  \n℃  \nkPa  \n℃  \n110  \n-9  \n38  \n862  \n-7  \n39  \n124  \n896  \n## Celsius\n\n#### 138\n\n-6  \n41  \n931  \n## Pressure/TemperatureChart\n\n#### 152\n\n-4  \n42  \n965  \n#### 165\n\n-3  \n43  \n1000  \n#### 179\n\n-1  \nEVAPORAT0  \n1034  \n44  \n#### 193\n\n0  \n1103  \n47  \n207  \n1172  \n49  \n51  \n221  \n2  \n1241  \n### Torque Settings\n\n234  \n4  \n53  \n1310  \n### \\#60-Ring Fitting:15-18N-m\\#80-Ring Fitting:20-27N-m\\#100-Ring Fiting:29-37N-m\\#120-RingFitting:38-41N-m\\#140-RingFitting:41-48N-mPressure switch onSchrader port(7620):910N-mPressure switchonM10 port:6-7N-mSchrader portvalveinsert:   34-56 N-cm\n\n248  \n5  \n1379  \n55  \n262  \n7  \n1448  \n57  \n276  \n9  \n1517  \n58  \n8  \n1586  \n290  \n61  \n#### 303\n\n1655  \n9  \n62  \n317  \n10  \n1724  \n64  \n〕ONDENSER  \n331  \n1793  \n  11     \n66  \n#### 345  12  \n\n1862  \n67  \n#### 379\n\n1931  \n#### 14\n\n68  \n#### 414\n\n17  \n70  \n1999  \n#### 448\n\n19  \n2068  \n71  \n2137  \n#### 483\n\n21  \n73  \n517  \n#### 23\n\n2206  \n74  \n552  \n24  \n2275  \n76  \n586  \n26  \n2344  \n77  \n621  \n28  \n2413  \n78  \n655  \n  29     \n79  \n2482  \n689  \n31  \n2551  \n81  \n724  \n33  \n82  \n2620  \n758  \n34  \n2689  \n83  \n 36    \n2758  \n84  \n793  \n827  \n37  \n85  \n2827  \nCopyright O2010 Red Dot Corporation  \nRD-5-13053-0P Rev-","cbCainIXPn9ZYziD","https://ap.wps.com/l/cbCainIXPn9ZYziD","pdf",148094,"English","# R-134a\n## Pressure/Temperature Chart\n## Torque Settings","[{\"question\":\"What units does the R-134a pressure/temperature chart provide?\",\"answer\":\"It provides pressure values in PSIG (psi gauge) and in kPa, mapped to Fahrenheit and Celsius temperature entries.\"},{\"question\":\"Does the chart cover both evaporator and condenser conditions?\",\"answer\":\"Yes. It includes labeled sections for EVAPORATOR (evaporator) and CONDENSER (condenser) ranges.\"},{\"question\":\"Where are the torque settings listed?\",\"answer\":\"The document includes a dedicated “Torque Settings” section with values for ring fittings and installation items, including pressure switch port torque specifications.\"}]","R-134a - Pressure/Temperature Chart | PDF",1791871342]