[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-564082-105":53,"doc-detail-564082-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","prime-conduit-schedule-40-80-conduit-elbows-technical-specifications","Prime Conduit™ Schedule 40 & 80 Conduit & Elbows - Technical Specifications","","Prime Conduit™ schedule 40 and schedule 80 rigid nonmetallic conduits and elbows are specified for use aboveground and underground in accordance with the National Electrical Code. The document highlights installation ease, nonconductive safety, impact and sunlight resistance, corrosion resistance, and weathering performance. It states manufacturing compliance with NEMA TC-2 and Federal specification WC1O94A and UL 651, including ETL listings. Detailed tables provide part numbers, trade sizes, standard crate quantities, weights per 100 ft, dimensions, and wall thickness, plus support spacing requirements per NEC Table 352.30(B).",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/prime-conduit-schedule-40-80-conduit-elbows-technical-specifications/564082/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/prime-conduit-schedule-40-80-conduit-elbows-technical-specifications/564082.png","ImageObject",442,249,{"name":88,"@type":89},"Mafia Boss","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-28","2026-10-12",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",8,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What standards and certifications are referenced for Prime Conduit conduits and elbows?","Question",{"text":109,"@type":110},"The document references manufacturing to NEMA TC-2, Federal specification WC1O94A, and UL 651, with corresponding ETL listings and labels, and compliance statements tied to NEC requirements.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"Where can the Schedule 40 and Schedule 80 conduits be used?",{"text":114,"@type":110},"Schedule 40 and Schedule 80 rigid nonmetallic conduits are described as suitable for both aboveground and underground applications, including listed exposed or outdoor usage and encased or direct burial scenarios for the heavy wall variants.",{"name":116,"@type":107,"acceptedAnswer":117},"What support spacing is required for rigid PVC nonmetallic conduit in aboveground installations?",{"text":118,"@type":110},"Support spacing is given by trade size using NEC Table 352.30(B), with maximum spacing ranging from 3 feet for 1/2-1 trade size up to 8 feet for 6 trade size.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},564082,1792083816,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":25,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":47},962090760730,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Prime Conduit™ Schedule 40 & 80 Conduit & Elbows  \nSchedule 40 Conduit  \nSchedule 80 Conduit  \n Schedule 40 Conduit Schedule 40 Elbows  \nSchedule 80 Elbows  Schedule 40 Elbows  \nProperties Expansion & Contraction Corrosion Resistance Specification  \nSchedule 40 Utility Conduit & Elbows  \nRigid Nonmetallic Conduit –Schedule 40 and Schedule80  \nPrime Conduit™ Rigid Nonmetallic Conduit (RNC)  \nPrime Conduit™ manufactures the most complete line of nonmetallic conduits in the electrical industry. Prime Conduit Schedule 40 and Schedule 80 conduits are designed for use aboveground and underground as described in the National Electrical Code. Specify only Prime Conduit conduits to insure raceway system quality.  \nFeatures  \nEase of Installation Nonmetallic conduits are 1/4 to 1/5 the weight of metallic systems, can be installed in less than half the time, and are easily fabricated on the job.  \nSafety Nonmetallic conduits are nonconductive, assuring a safe system.  \nImpact Resistant Prime Conduit Schedule 40 and Schedule 80 nonmetallic conduits are resistant to sunlight and are listed for exposed or outdoor usage.  \nCorrosion Resistant Prime Conduit conduits are nonmetallic and will not rust or corrode.  \nPrime Conduit nonmetallic Schedule 40 and Schedule 80 conduits and elbows are manufactured to NEMA TC-2, Federal specification WC1O94A and UL 651 specifications. The conduit carries respective ETL Listings and ETL labels.  \nPrime Conduit Schedule 40 PVC Rigid Nonmetallic Conduit (RNC).  \n(Heavy Wall EPC)  \nListed for underground applications encased in concrete or direct burial. Also for use in exposed or concealed applications aboveground.  \n• Sunlight resistant • Rated for use with 90˚C conductors  \n• Superior weathering characteristics • Made in USA  \nWith Integral Bell*  \n| Part No. |  | Trade Size | Std. Crate Qty. |  | Wt. Per\u003Cbr>100' | Dimensions |  | Wall |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 10' | 20' |  | 10' | 20' |  | O.D. | I.D. |  |\n| 49005-010 |  | 1/2\" | 6000' |  | 17 | .840 | .622 | .109 |\n| 49007-010 | 49007-020 | 3/4\" | 4400' | 8800' | 23 | 1.050 | .824 | .113 |\n| 49008-010 | 49008-020 | 1\" | 3600' | 7200' | 34 | 1.315 | 1.049 | .133 |\n| 49009-010 | 49009-020 | 11/4\" | 3300' | 6600' | 46 | 1.660 | 1.380 | .140 |\n| 49010-010 | 49010-020 | 11/2\" | 2250' | 4500' | 55 | 1.900 | 1.610 | .145 |\n| 49011-010 | 49011-020 | 2\" | 1400' | 2800' | 73 | 2.375 | 2.067 | .154 |\n| 49012-010 | 49012-020 | 21/2\" | 930' | 1860' | 124 | 2.875 | 2.469 | .203 |\n| 49013-010 | 49013-020 | 3\" | 880' | 1760' | 163 | 3.500 | 3.068 | .216 |\n| 49014-010 | 49014-020 | 31/2\" | 630' | 1260' | 196 | 4.000 | 3.548 | .226 |\n| 49015-010 | 49015-020 | 4\" | 570' | 1140' | 232 | 4.500 | 4.026 | .237 |\n| 49016-010 | 49016-020 | 5\" | 380' | 760' | 315 | 5.563 | 5.047 | .258 |\n| 49017-010 | 49017-020 | 6\" | 260' | 520' | 409 | 6.625 | 6.065 | .280 |\n\nSchedule 40 Heavy Wall  \nRigid nonmetallic conduit is normally supplied in standard 10' lengths, with one belled end per length. For specific requirements, it may be produced in lengths shorter or longer than 10', with or without belled ends.  \nUse RNC Fittings with Schedule 40 and Schedule 80 Conduit.  \nNotes: 1. Special conduit sizes will be quoted on request.  \n2. DON’T FORGET TO ORDER CEMENT.  \n3. Prime conduit reserves the right to ship to the nearest unitized quantity.  \nRigid Nonmetallic Conduit –Support in Aboveground Installations   \nPrime Conduit Schedule 80 PVC Rigid Nonmetallic Conduit (RNC)  \n(Extra Heavy Wall EPC-80)  \nListed for use in aboveground and belowground applications including areas subject to physical damage.  \n• Sunlight resistant • Rated for use with 90˚C conductors • Superior weathering characteristics  \n• Identified for use in areas subject to physical damage in accordance to 352.12(C)  \nRUS Accepted  \nETL Listed to UL 651 in compliance to the NEC  \nWith Integral Bell*  \nSchedule 80 Extra Heavy Wall  \n\n| Part No. |  | Trade Size | Std. Crate Qty. |  | Wt. Per\u003Cb","cbCailX0S9JR5yMn","https://ap.wps.com/l/cbCailX0S9JR5yMn","pdf",571425,"English","# Schedule 40 Conduit & Elbows\n## Properties and features\n## Schedule 40 PVC Rigid Nonmetallic Conduit (RNC) - dimensions and part numbers\n# Schedule 40 Heavy Wall\n## Supply notes and ordering guidance\n## RNC fittings usage\n# Schedule 80 Conduit & Elbows\n## Properties and features\n## Schedule 80 Extra Heavy Wall - dimensions and part numbers\n# Support requirements and installation notes\n## NEC Table 352.30(B) support spacing\n## Installation guidance (temperature and spacing)","[{\"question\":\"What standards and certifications are referenced for Prime Conduit conduits and elbows?\",\"answer\":\"The document references manufacturing to NEMA TC-2, Federal specification WC1O94A, and UL 651, with corresponding ETL listings and labels, and compliance statements tied to NEC requirements.\"},{\"question\":\"Where can the Schedule 40 and Schedule 80 conduits be used?\",\"answer\":\"Schedule 40 and Schedule 80 rigid nonmetallic conduits are described as suitable for both aboveground and underground applications, including listed exposed or outdoor usage and encased or direct burial scenarios for the heavy wall variants.\"},{\"question\":\"What support spacing is required for rigid PVC nonmetallic conduit in aboveground installations?\",\"answer\":\"Support spacing is given by trade size using NEC Table 352.30(B), with maximum spacing ranging from 3 feet for 1/2-1 trade size up to 8 feet for 6 trade size.\"}]","Prime Conduit™ Schedule 40 & 80 Conduit & Elbows - Technical Specifications | PDF",1791840160]