[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-565299-105":53,"doc-detail-565299-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","pressure-temperature-chart-a-gas","Pressure Temperature Chart - A-GAS","","Pressure-Temperature chart for A-GAS that provides cross-reference values between gauge pressure (kPa) and temperature for multiple refrigerants and related substances. The table organizes columns by refrigerant codes such as R12, R134a, R22, R507A, R744 CO₂, R717 NH₃, and hydrocarbon options like R600a, showing temperature ranges across the full pressure grid. It supports quick lookup for system design, diagnostics, and troubleshooting.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/pressure-temperature-chart-a-gas/565299/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/pressure-temperature-chart-a-gas/565299.png","ImageObject",442,249,{"name":88,"@type":89},"kopisore","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-31","2026-10-13",true,{"@type":98,"interactionType":99,"userInteractionCount":8},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What does the chart relate to pressure and temperature?","Question",{"text":108,"@type":109},"It maps gauge pressure in kPa to temperature values across a table grid for many refrigerants and substances.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"Which parameter is shown in the first column?",{"text":113,"@type":109},"The first column is pressure measured in kPa (Gauge), used as the lookup axis for temperatures.",{"name":115,"@type":106,"acceptedAnswer":116},"How are refrigerants represented in the chart?",{"text":117,"@type":109},"Each refrigerant appears as a labeled column header (e.g., R12, R134a, R22, R744 CO₂, R717 NH₃), with temperature values listed under it for each pressure row.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},565299,1792024618,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":8,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":9,"language":135,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":136,"faqs":137,"seo_title":138,"seo_description":61,"update_tm":139,"read_time":4},962090880963,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","A-GAS  \n# Pressure Temperature Chart\n\nTOGETHER WE CAN  \n\n| Pressure kPa(Gauge)   |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| C   | R12   | R134a   | R4  \u003Cbr>Dewl   | 06A  \u003Cbr>Rub   | R4  \u003Cbr>Dew   | 08A  \u003Cbr>Bub   | R32   | R4  \u003Cbr>Dew   | 07F  \u003Cbr>Bub    | R4  \u003Cbr>Dew    | 7A  \u003Cbr>Bub    | R4  \u003Cbr>Dew   | 04A  \u003Cbr>Bub   | R4  \u003Cbr>Dew   | 07C  \u003Cbr>Bub   | R4  \u003Cbr>Dew   | 0A  \u003Cbr>Rub   | R22   | R507A   | R448A  \u003Cbr>Bub   |  | R449A  \u003Cbr>Bub   |  | R452A  \u003Cbr>Bub   |  | R744  \u003Cbr>CO₂   | R513A   | R514A   | R717  \u003Cbr>NH₃   | R600a  \u003Cbr>Butane   | R290  \u003Cbr> Propane   | R1234yf  \u003Cbr>HFO   | R1233zd  \u003Cbr>HFO   | R1234ze  \u003Cbr>HFO   |\n| -48   | -58   | -68   | -72   | -53   | -17   | -15   | 20   | -36   | -9   | -36   | -52   | -12   | -8   | -45   | -19   | 19   | 19   | -30   | -6   | -38   | -14   | -40   | -18   | -26   | -10   | 638   | -60   | -99   | -55   | -83   | -23   | -60   | -77   | -78   |\n| -46   | -53   | -64   | -68   | -47   | -9   | -7   | 33   | -28   | 0   | -29   | -46   | -3   | 1   | -39   | -11   | 31   | 31   | -22   | 4   | -31   | -5   | -33   | -9   | -18   | -1   | 699   | -56   | -99   | -50   | -80   | -17   | -55   | -74   | -75   |\n| -44   | -48   | -60   | -65   | -42   | 1   | 3   | 46   | -20   | 10   | -21   | -40   | 8   | 11   | -32   | -2   | 44   | 45   | -14   | 14   | -23   |  | -26   | 0   | -9   | 9   | 763   | -51   | -99   | -43   | -78   | -8   | -50   | -71   | -72   |\n| -42   | -43   | -55   | -60   | -36   | 11   | 13   | 61   | -11   | 22   | -13   | -33   | 18   | 22   | -24   | 8   | 58   | 59   | -6   | 25   | -15   | 15   | -18   | 10   | 0   | 20   | 831   | -45   | -98   | -37   | -75   | 1   | -45   | -68   | -68   |\n| -40   | -37   | -50   | -56   | -29   | 21   | 24   | 76   | -1   | 34   | -4   | -25   | 30   | 34   | -16   | 19   | 74   | 74   | 4   | 37   | -6   | 26   | -9   | 21   | 10   | 32   | 903   | -39   | -98   | -30   | -73   | 10   | -39   | -64   | -65   |\n| -38   | -31   | -45   | -51   | -22   | 33   | 35   | 93   | 9   | 47   | 5   | -18   | 42   | 47   | -7   | 30   | 90   | 90   | 14   | 50   | 4   | 38   | 0   | 33   | 21   | 44   | 979   | -33   | -97   | -21   | -70   | 20   | -32   | -60   | -61   |\n| -36   | -24   | -38   | -46   | -15   | 45   | 48   | 111   | 20   | 61   | 15   | -9   | 55   | 60   | 3   | 43   | 108   | 108   | 25   | 64   | 14   | 51   | 10   | 46   | 33   | 58   | 1059   | -26   | -97   | -13   | -66   | 30   | -26   | -56   | -56   |\n| -34   | -17   | -32   | -40   | -6   | 58   | 61   | 130   | 32   | 75   | 26   | 1   | 70   | 74   | 14   | 56   | 126   | 127   | 37   | 79   | 26   | 65   | 2   | 59   | 45   | 72   | 1144   | -19   | -96   | -3   | -63   | 41   | -19   | -51   | -51   |\n| -32   | -10   | -25   | -34   | 2   | 73   | 76   | 150   | 45   | 91   | 38   | 10   | 85   | 90   | 25   | 70   | 147   | 147   | 49   | 94   | 38   | 80   | 33   | 73   | 58   | 87   | 1233   | -11   | -96   | 7   | -59   | 54   | -11   | -45   | -46   |\n| -30   | -1   | -17   | -27   | 12   | 88   | 91   | 172   | 59   | 108   | 50   | 21   | 101   | 106   | 37   | 85   | 168   | 169   | 63   | 112   | 51   | 96   | 46   | 89   | 72   | 104   | 1326   | -2   | -95   | 18   | -55   | 66   | -2   | -40   | -40   |\n| -28   | 8   | -9   | -19   | 22   | 104   | 107   | 195   | 74   | 126   | 63   | 33   | 118   | 124   | 50   | 102   | 191   | 192   | 76   | 130   | 65   | 113   | 59   | 105   | 88   | 121   | 1425   | 7   | -94   | 30   | -50   | 80   | 7   | -34   | -34   |\n| -26   | 17   | 0   | -12   | 32   | 12:   | 125   | 220   | 90   | 145   | 78   | 45   | 136   | 143   | 65   | 119   | 215   | 216   | 92   | 148   | 80   | 131   | 74   | 123   | 105   | 140","cbCairNbxlshDS52","https://ap.wps.com/l/cbCairNbxlshDS52","pdf",2417989,"English","# Pressure Temperature Chart\n## Gauge pressure vs temperature grid","[{\"question\":\"What does the chart relate to pressure and temperature?\",\"answer\":\"It maps gauge pressure in kPa to temperature values across a table grid for many refrigerants and substances.\"},{\"question\":\"Which parameter is shown in the first column?\",\"answer\":\"The first column is pressure measured in kPa (Gauge), used as the lookup axis for temperatures.\"},{\"question\":\"How are refrigerants represented in the chart?\",\"answer\":\"Each refrigerant appears as a labeled column header (e.g., R12, R134a, R22, R744 CO₂, R717 NH₃), with temperature values listed under it for each pressure row.\"}]","Pressure Temperature Chart - A-GAS | PDF",1791850847]