[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-393263-105":53,"doc-detail-393263-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","panel-load-calculation-factory-built-structures-commercial-coaches-electrical-plan-approval-request","PANEL LOAD CALCULATION - Factory Built Structures & Commercial Coaches - Electrical Plan Approval Request","","Panel load calculation worksheet and electrical plan approval request for factory built structures and commercial coaches, including main distribution panel sizing details and spare conduit and wiring provisions. The document defines connected load and demand calculated load, explains adjustment factors and conversion between KVA and amps for feeder and equipment sizing, and provides sample one-line diagram references. It also includes instructions and fee-approval form fields for submission, department use, electrical plan review units, ampacity brackets, surcharges, and required plan items and checklists.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":46,"@type":70,"position":76},"https://docshare.wps.com/template/paper-templates/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/panel-load-calculation-factory-built-structures-commercial-coaches-electrical-plan-approval-request/393263/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/panel-load-calculation-factory-built-structures-commercial-coaches-electrical-plan-approval-request/393263.png","ImageObject",442,249,{"name":88,"@type":89},"Ezra","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-12","2026-09-26",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",8,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"How are connected load and demand calculated load defined in this document?","Question",{"text":109,"@type":110},"Connected load is the nameplate rating of appliances permanently connected on a specific circuit, plus general-use receptacle VA and lighting fixture maximum VA, and full-load motor ratings. Demand calculated load is the connected load after code-required adjustment factors are applied and expressed in KVA, then converted to amps for sizing feeders and equipment.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"What does the document require for electrical plan submission before approval review?",{"text":114,"@type":110},"It lists required items such as electrical floor plans with related drawings (minimum two complete sets), a one line/riser diagram, specifications, load calculations, fault calculations, metered demand records, and panel schedules.",{"name":116,"@type":107,"acceptedAnswer":117},"What fee review elements are included in the plan approval request form?",{"text":118,"@type":110},"The form includes electrical plan submission fee, service/feeder ampacity unit categories, possible generator-related fees, surcharges (including over 600 volts), and totals for fees paid, along with notes about altered services or feeders being charged according to the fee schedule.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},393263,1790901797,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":45,"category_name":46,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":47,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":73},1099514068035,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","PANEL LOAD CALCULATION  \nDate  \nManufacturer's Serial Number  \nPanel  \nLoad Type  \nConnected Load  \nDemand Factor  \nDemand Load  \nLighting  \nGen use receptacles \u003C10 KVA  \nGen use receptacles > 10 KVA Motors & compressors  \n(Largest) Computer receptacles Mechanical & HVAC Kitchen equipment Miscellaneous  \nMiscellaneous  \n|  |\n| --- |\n|  |\n|  |\n|  |\n|  |\n|  |\n\nX 125%  \nX 100%  \nX 50%  \nX 100%  \nX 25%  \nX 100%  \nX 100%  \nX   %  \nX 100%  \nX  %  \nX  %  \nX  %  \n=  \n=  \n=  \n=  \n=  \n=  \n=  \n=  \n=  \n=  \n=  \n=  \n\n|  |\n| --- |\n|  |\n|  |\n|  |\n|  |\n|  |\n|  |\n|  |\n|  |\n|  |\n|  |\n\nDefinitions:  \nConnected amps Demand amps  \nConnected load  \n1. The nameplate rating of all appliances that are fastened in place, permanently connected to located to be on specific circuit. (Water heaters, space heaters, ranges, refrigerators, etc.)  \n2. 180 VA for each general use receptacle  \n3. Maximum VA of lighting fixtures  \n4. Full load amps/KVA ofall motors from Table 430-147, 148, 149 and 150 of the National Electric Code  \nDemand calculated load  \nThe connected load after any code required adjustment factor has been applied. Load calculations shall be submitted/expressed in KVA and converted to amps when sizing feeders and equipment.  \nF623-017-000 panel load calculation 8-98 (page 1 of 5)  \nMAIN DISTRIBUTION PANEL (MKP), 1200A, 208/ 120V, 3 PHASE  \nSPARE  \nSPARE  \n(2) 2\" GALV RIGID STEEL OR (1) 3\" GALV RIGID STEEL  \n2 SETS (4) 3/0 THHN CU & \\#3 CU GND  \n(1) 2\" GALV RIGID STEEL  \n(4) 3/0 THHN CU & \\#8 CU GND  \n(1) 2\" GALV RIGID STEEL  \n(4) 3/0 THHN CU & \\#6 CU GND  \n(1) 2\" GALV RIGID STEEL  \n(4) 3/0 THHN CU & \\#6 CU GND  \nSAMPLE ONE-LINE DIAGRAM  \n|  |\n| --- |\n|  |\n\n. .  \n. .  \n. .  \n. .  \n.  .  \n. .  \n. .  \nM  \n200A 3P  \n200A 200A 100A 400A 200A  \n3P 3P 3P 3P 3P  \n\u003C10000A \u003C10000A \u003C10000A \u003C10000A  \nSYM SYM SYM SYM  \n200A 225A MLO 100A MLO 400A MLO 400A MLO  \nM .BKR BUS BUS BUS BUS  \nPANEL PANEL  \nPANEL PANEL  \nPANEL B C K K  \nA SEC . 1 SEC .2  \nFEED-THRU LUGS  \n225A  \nBUS  \n))  \n1200A 3P  \n1200A BUS  \nx 37650A SYM .  \nF623-017-000 sample one-line diagram 8-98 (page 2 of 5)  \nFor Postal Delivery  \nDepartment of Labor and Industries Factory Assembled Structures PO Box 44430  \nOlympia WA 98504-4430  \nFor Non-Postal Delivery (e.g., FedX, UPS)  \nDepartment of Labor and Industries Factory Assembled Structures 7273 Linderson Way SW Tumwater WA 98501  \nFB  \nCCF CH 11  \nWA Only  \nWA Rev/ORCourtesy OR Rev/WA Courtesy   Other state State ID reciprocity  \n3  \n[www.wa.gov/lni](www.wa.gov/lni) (case sensitive)  \nELECTRICAL PLAN APPROVAL REQUEST FACTORY BUILT STRUCTURES & COMMERCIAL COACHES  \nManufacturer  \nApplicant: Fill out completely  \n1 Mfg No.  \n2  \nPlans to be returned to: Address  \nCity/State/ZIP  \nFOR DEPARTMENT USE ONLY  \n\n| Fee Ledger Sheet \\# |  | Application ID |\n| --- | --- | --- |\n| Ap No. | Date approved | Expiration date |\n\nContact person's printed name:  \nDate  \nFee enclosed  \n$  \nSignature  \nPhone No  \nFAX No  \n4  \nNew plan Addendum Renewal Resubmittal Plan App oval No    \nBuilding  \nSerial No.   Area Sq. Ft    \nOccupancey Group:/ /  \nUse:  \n7  \n8  \n9  \n10  \n5  \n11  \n6  \nInstallation locatio  \n 13   \nCity  \nState  \nZIP+4  \nCounty  \n| ELECTRICAL PLAN REVIEW (When required by WAC 296-46-140, Plan review for educational, institutional or health care facilities and other buildings. See WAC 296-150 C/F-3000 for fee schedule) | Unit |  |  | Unit\u003Cbr>Amount | Total\u003Cbr>Amount |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| Electrical plan submission fee 14 |  |  |  |  |  |  |\n| Service/Feeder ampacity: Each design option is addtional. |  |  |  |  |  |  |\n| 0-100 |  |  |  |  |  |  |\n| 101-200 |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n| 201-400 |  |  |  |  |  |  |\n| 401-600 |  |  |  |  |  |  |\n| 601-800 f623-016-000 sample |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n| 801-1000 |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n| Over 1000 |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n| instructions  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n| Over 600 volts surcharge ","cbCaig3uhyh9WYmE","https://ap.wps.com/l/cbCaig3uhyh9WYmE","pdf",173555,"English","# Definitions\n# Panel load calculation inputs\n# Main distribution panel and spare details\n# Sample one-line diagram\n# Electrical plan approval request form fields\n# Electrical plan review fee ledger and instructions","[{\"question\":\"How are connected load and demand calculated load defined in this document?\",\"answer\":\"Connected load is the nameplate rating of appliances permanently connected on a specific circuit, plus general-use receptacle VA and lighting fixture maximum VA, and full-load motor ratings. Demand calculated load is the connected load after code-required adjustment factors are applied and expressed in KVA, then converted to amps for sizing feeders and equipment.\"},{\"question\":\"What does the document require for electrical plan submission before approval review?\",\"answer\":\"It lists required items such as electrical floor plans with related drawings (minimum two complete sets), a one line/riser diagram, specifications, load calculations, fault calculations, metered demand records, and panel schedules.\"},{\"question\":\"What fee review elements are included in the plan approval request form?\",\"answer\":\"The form includes electrical plan submission fee, service/feeder ampacity unit categories, possible generator-related fees, surcharges (including over 600 volts), and totals for fees paid, along with notes about altered services or feeders being charged according to the fee schedule.\"}]","PANEL LOAD CALCULATION - Factory Built Structures & Commercial Coaches - Electrical Plan Approval Request | PDF",1790382228]