[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-572028-105":53,"doc-detail-572028-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","mgsp-cheat-sheet","MGSP Cheat Sheet","","Quick-reference programming guidance for Magellan & Spectra TM50 control panels, presenting AU defaults and configurable parameter tables. Includes zone setup (locations and zone options), dialer settings with account/phone data, installer and system master codes, and timer values such as entry delay, swinger shutdown, and bell/AC fail delays. Also lists PGM and panel programming functions, user report codes, EOL and label ranges, plus wireless zone/keyfob/keypad and wireless PGM registration fields with signal strength and serial number placeholders.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/mgsp-cheat-sheet/572028/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/mgsp-cheat-sheet/572028.png","ImageObject",442,249,{"name":88,"@type":89},"\tJames","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-22","2026-10-13",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",8,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What does the guide cover for MGSP/TM50 systems?","Question",{"text":109,"@type":110},"It provides AU default quick-programming references, including zones, dialer options, installer/system master codes, timers, PGM settings, user report codes, and wireless device configuration ranges.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"How are default panels and reset behavior described?",{"text":114,"@type":110},"It notes using the default panel control “ONCE only” and explains the reset switch procedure: press and hold until the status light flashes fast, release, then press again once quickly.",{"name":116,"@type":107,"acceptedAnswer":117},"What information is provided for wireless setup?",{"text":118,"@type":110},"It lists wireless zones, keyfobs, keypads, and wireless PGM ranges with related labels, signal-strength ranges, and serial-number fields that are intended to be filled in.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},572028,1792124524,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":73,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":9},2336474466412,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Touch Screen TM50  \nTouch and hold  -  - Default panel  ONCE only!  \nLed Keypads  \n-  \nDefault panel  ONCE only!  \nReset Switch  \nPress and hold until status light flashes fast, release, then press again once quickly.  \nMagellan & Spectra Quick Programming Guide AU Defaults V1 .7  \n| Zones 001 ~ 032 (32 Zones) |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| Location | Zone | Type | Area | Zone Options |\n| 001 | 1 | 01 | 1 | 1 2 3 4 5 6 7 8 |\n| 002 | 2 | 06 | 1 | 1 2 3 4 5 6 7 8 |\n| 003 | 3 | 09 | 1 | 1 2 3 4 5 6 7 8 |\n| 004 | 4 | 09 | 1 | 1 2 3 4 5 6 7 8 |\n| 005 | 5 | 09 | 1 | 1 2 3 4 5 6 7 8 |\n| 006 | 6 | 09 | 1 | 1 2 3 4 5 6 7 8 |\n| 007 | 7 | 09 | 1 | 1 2 3 4 5 6 7 8 |\n| 008 | 8 | 09 | 1 | 1 2 3 4 5 6 7 8 |\n\n| Dialler |  |  |\n| --- | --- | --- |\n| Location | Features | Data |\n| Note | Account Number (811) 0 = A on TM50 |  |\n| 811 | Account P1 | _ _ _ _ |\n| 815 | Phone \\# 1 | _ _ _ _ _ _ _ _ _ _ |\n| 817 | Backup Phone | _ _ _ _ _ _ _ _ _ _ |\n| 840 | Auto Test Days | 007 |\n| 850 | Auto Test Time | 02 : 00 |\n|  |  |  |\n|  |  |  |\n\n\n| Installer / Master Codes |  |  |\n| --- | --- | --- |\n| Location | Codes | Data |\n| 397 | Installer | 0000 |\n| 399 | System Master | 1234 |\n\n\n| Timers |  |  |  |\n| --- | --- | --- | --- |\n| Location | Features | Data |  |\n| 710 | Entry Delay 1 |  | 030 |\n| 712 | Swinger Shutdown |  | 001 |\n| 713 | Twin Trip Timer |  | 048 |\n| 720 | Sleep Entry Delay |  | 015 |\n| 745 | Area 1 Exit Time |  | 045 |\n| 747 | Bell Timer |  | 004 |\n| 839 | AC Fail Delay |  | 015 |\n|  |  |  |  |\n\n\n| PGM's (Panel specific) |  |\n| --- | --- |\n| PGM 1 | Strobe |\n| PGM 2 | Screamer |\n| PGM 3 | Smoke Reset |\n| PGM 4 | Button C on Remote |\n| PGM 5 | Button C on Remote |\n\n\n| 700 |  | 701 |  | 702 |  | 703 |  | 704 |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1 | Partitioning | 1 | 4 digit code | 1 | Panic 1, Police | 1 | Quick arm away | 1 | Force arm away |\n| 2 | Battery charge increase | 2 | Lock master code | 2 | Panic 2, Medical | 2 | Quick arm stay | 2 | Force arm stay |\n| 3 | C/Pad beeps on trouble | 3 | Confidential mode | 3 | Panic 3, Fire | 3 | Quick arm sleep | 3 | Force arm sleep |\n| 4 | C/Pad beeps on AC fail | 4 | Key to exit confidential | 4 | Panic 1, audible | 4 | Quick bypass | 4 | Bell squawk / remotes |\n| 5 | RF jam supervision | 5 | Confidential time 5sec | 5 | Panic 2, audible | 5 | No Arm if battery fail | 5 | Bell squawk / keypad |\n| 6 | Exit delay termination | 6 | REM2 V2 .01 up | 6 | Panic 3, audible | 6 | No Arm if tamper | 6 | Exit Beeps enabled |\n| 7 | Tmp sup. on bus/module | 7 | Entry delay on LCD | 7 | N/A | 7 | No Arm if supervision | 7 | No exit beeps / stay arm |\n| 8 | N/A | 8 | Exit delay on LCD | 8 | N/A | 8 | Arm/Disarm VDMP3 | 8 | No exit delay / remotes |\n\n\n| 705 |  | 706 |  | 800 |  | 801 |  | 802 |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1 | Zone Doubling | 1 | Supervision check in | 1 | Phone line monitor | 1 | Open ONLY after alarm | 1 | Open/Close Rec \\# 1 |\n| 2 | Parallel EOLs | 2 | EOLs enabled | 2 | Phone line monitor | 2 | Zone restores | 2 | Open/Close Rec \\# 2 |\n| 3 | Zone tamper | 3 | 2 Wire smoke | 3 | Pulse dialling | 3 | Auto test | 3 | Open/Close Pager |\n| 4 | Zone tamper | 4 | ZX8 A Zone 1 = tamper | 4 | Alternate dial | 4 | Auto test | 4 | N/A |\n| 5 | Tamper on bypass | 5 | ZX8 B Zone 1 = tamper | 5 | Force dial | 5 | Contact ID override | 5 | Alarm/Restores Rec \\# 1 |\n| 6 | Wireless supervision | 6 | ZX8 C Zone 1 = tamper | 6 | DTMF | 6 | Bell on alarm kissoff | 6 | Alarm/Restores Rec \\# 2 |\n| 7 | Wireless supervision | 7 | N/A | 7 | Pulse ratio | 7 | Bell on arming kissoff | 7 | Alarm/Restores Pager |\n| 8 | Supervision on bypass | 8 | N/A | 8 | Deactivate dialler | 8 | C/Pad beeps on kissoff | 8 | N/A |\n\n\n| User Report Codes 471 ~ 502 (32 users)\u003Cbr>FF FF for Commercial installations |  |  |\n| --- | --- | --- |\n| Location | Codes | Data |\n| 471 | User 1 | 00 FF |\n| 472 | User 2 | 00 FF |\n| 473 | User 3 | 00 FF |\n| 474 | Us","cbCaiowZjiMcKd7x","https://ap.wps.com/l/cbCaiowZjiMcKd7x","pdf",358817,"English","# Touch Screen and Defaults\n# Zones and Zone Options\n# Dialler Settings\n# Installer/Master Codes\n# Timers\n# PGM and Panel Programming\n# User Report Codes and Labels\n# Wireless Configuration (Zones, Keyfobs, Keypads, PGM)","[{\"question\":\"What does the guide cover for MGSP/TM50 systems?\",\"answer\":\"It provides AU default quick-programming references, including zones, dialer options, installer/system master codes, timers, PGM settings, user report codes, and wireless device configuration ranges.\"},{\"question\":\"How are default panels and reset behavior described?\",\"answer\":\"It notes using the default panel control “ONCE only” and explains the reset switch procedure: press and hold until the status light flashes fast, release, then press again once quickly.\"},{\"question\":\"What information is provided for wireless setup?\",\"answer\":\"It lists wireless zones, keyfobs, keypads, and wireless PGM ranges with related labels, signal-strength ranges, and serial-number fields that are intended to be filled in.\"}]","MGSP Cheat Sheet | PDF",1791925113]