[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-571084-105":53,"doc-detail-571084-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","metric-steam-tables-table-of-saturated-steam-properties","Metric Steam Tables - Table of saturated steam properties","","Metric Steam Tables provide saturation-property lookups for water and steam over a range of gauge pressures, listing corresponding absolute pressure, saturation temperature, specific volumes for saturated liquid (vf) and saturated vapor (vg), and thermal quantities. The table includes liquid heat (hf), latent heat of vaporization (hfg), and total steam enthalpy (hg), with values presented in kJ/kg for each pressure step, supporting engineering calculations, thermodynamic analysis, and energy balance work.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/metric-steam-tables-table-of-saturated-steam-properties/571084/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/metric-steam-tables-table-of-saturated-steam-properties/571084.png","ImageObject",442,249,{"name":88,"@type":89},"Himbo","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-24","2026-10-13",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",8,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What pressure scale does the table start from?","Question",{"text":109,"@type":110},"The table uses gauge pressure (barg) in the first column and converts it to absolute pressure (bara) for each row.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"Which thermodynamic quantities are provided for saturated water and steam?",{"text":114,"@type":110},"It provides saturation temperature, specific volumes for saturated liquid (vf) and saturated steam (vg), and heat properties: hf, hfg, and total enthalpy hg in kJ/kg.",{"name":116,"@type":107,"acceptedAnswer":117},"How can these tables be used in calculations?",{"text":118,"@type":110},"Select the operating gauge pressure to read the matching saturation temperature and enthalpy/heat terms, then use vf/vg and hf/hfg/hg for energy balance, phase-change, and thermodynamic estimation.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},571084,1792107662,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":47,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":73},687197100911,"https://ap-avatar.wpscdn.com/avatar/a000239b6f1da00475?x-image-process=image/resize,m_fixed,w_180,h_180&k=1785132997149421697","[www.invenoeng.com](www.invenoeng.com) Inveno Engineering, LLC Metric Steam Tables  \n\n| Pressure |  | Temperature | Specific Volume |  | Heat-kJ/kg | Enthalpy-kJ/kg |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| Gauge\u003Cbr>barg | Absolute bara | Saturation Deg. °C | Water vf\u003Cbr>m3/kg | Steam vg\u003Cbr>m3/kg | Liquid hf | Lat. Heat\u003Cbr>hfg | Total STM Heat hg |\n| 0 | 1.01 | 99.97 | 0.001043 | 1.673 | 418.99 | 2256.5 | 2675.5 |\n| 0.10 | 1.11 | 102.63 | 0.001046 | 1.532 | 430.21 | 2249.5 | 2679.7 |\n| 0.20 | 1.21 | 105.10 | 0.001048 | 1.414 | 440.64 | 2242.9 | 2683.5 |\n| 0.30 | 1.31 | 107.41 | 0.001049 | 1.313 | 450.39 | 2236.7 | 2687.1 |\n| 0.40 | 1.41 | 109.57 | 0.001051 | 1.226 | 459.55 | 2230.9 | 2690.4 |\n| 0.50 | 1.51 | 111.61 | 0.001053 | 1.150 | 468.20 | 2225.3 | 2693.5 |\n| 0.60 | 1.61 | 113.55 | 0.001055 | 1.083 | 476.40 | 2220.0 | 2696.4 |\n| 0.70 | 1.71 | 115.39 | 0.001056 | 1.024 | 484.20 | 2215.0 | 2699.2 |\n| 0.80 | 1.81 | 117.14 | 0.001058 | 0.971 | 491.63 | 2210.1 | 2701.8 |\n| 0.90 | 1.91 | 118.82 | 0.001059 | 0.923 | 498.75 | 2205.5 | 2704.2 |\n| 1.00 | 2.01 | 120.42 | 0.001061 | 0.880 | 505.57 | 2201.0 | 2706.5 |\n| 1.10 | 2.11 | 121.96 | 0.001062 | 0.841 | 512.13 | 2196.6 | 2708.8 |\n| 1.20 | 2.21 | 123.44 | 0.001063 | 0.806 | 518.44 | 2192.5 | 2710.9 |\n| 1.30 | 2.31 | 124.87 | 0.001065 | 0.773 | 524.52 | 2188.4 | 2712.9 |\n| 1.40 | 2.41 | 126.25 | 0.001066 | 0.743 | 530.40 | 2184.5 | 2714.9 |\n| 1.50 | 2.51 | 127.59 | 0.001067 | 0.715 | 536.09 | 2180.7 | 2716.7 |\n| 1.60 | 2.61 | 128.88 | 0.001069 | 0.689 | 541.60 | 2176.9 | 2718.5 |\n| 1.70 | 2.71 | 130.13 | 0.001070 | 0.666 | 546.95 | 2173.3 | 2720.3 |\n| 1.80 | 2.81 | 131.35 | 0.001071 | 0.643 | 552.14 | 2169.8 | 2721.9 |\n| 1.90 | 2.91 | 132.53 | 0.001072 | 0.623 | 557.19 | 2166.4 | 2723.5 |\n| 2.00 | 3.01 | 133.68 | 0.001073 | 0.603 | 562.10 | 2163.0 | 2725.1 |\n| 2.10 | 3.11 | 134.79 | 0.001074 | 0.585 | 566.88 | 2159.7 | 2726.6 |\n| 2.20 | 3.21 | 135.88 | 0.001076 | 0.568 | 571.55 | 2156.5 | 2728.0 |\n| 2.30 | 3.31 | 136.94 | 0.001077 | 0.552 | 576.10 | 2153.4 | 2729.5 |\n| 2.40 | 3.41 | 137.98 | 0.001078 | 0.537 | 580.54 | 2150.3 | 2730.8 |\n| 2.50 | 3.51 | 138.99 | 0.001079 | 0.522 | 584.88 | 2147.3 | 2732.1 |\n| 2.60 | 3.61 | 139.98 | 0.001080 | 0.509 | 589.13 | 2144.3 | 2733.4 |\n| 2.70 | 3.71 | 140.95 | 0.001081 | 0.496 | 593.28 | 2141.4 | 2734.7 |\n| 2.80 | 3.81 | 141.90 | 0.001082 | 0.484 | 597.35 | 2138.5 | 2735.9 |\n| 2.90 | 3.91 | 142.82 | 0.001083 | 0.472 | 601.33 | 2135.7 | 2737.1 |\n| 3.00 | 4.01 | 143.73 | 0.001084 | 0.461 | 605.24 | 2133.0 | 2738.2 |\n| 3.10 | 4.11 | 144.62 | 0.001085 | 0.450 | 609.07 | 2130.3 | 2739.3 |\n| 3.20 | 4.21 | 145.49 | 0.001086 | 0.440 | 612.82 | 2127.6 | 2740.4 |\n| 3.30 | 4.31 | 146.35 | 0.001087 | 0.431 | 616.51 | 2125.0 | 2741.5 |\n| 3.40 | 4.41 | 147.19 | 0.001087 | 0.422 | 620.13 | 2122.4 | 2742.5 |\n| 3.50 | 4.51 | 148.02 | 0.001088 | 0.413 | 623.69 | 2119.8 | 2743.5 |\n| 3.60 | 4.61 | 148.83 | 0.001089 | 0.404 | 627.19 | 2117.3 | 2744.5 |\n| 3.70 | 4.71 | 149.62 | 0.001090 | 0.396 | 630.63 | 2114.8 | 2745.5 |\n| 3.80 | 4.81 | 150.41 | 0.001091 | 0.388 | 634.01 | 2112.4 | 2746.4 |\n| 3.90 | 4.91 | 151.18 | 0.001092 | 0.381 | 637.34 | 2110.0 | 2747.3 |\n| 4.00 | 5.01 | 151.94 | 0.001093 | 0.374 | 640.62 | 2107.6 | 2748.2 |\n| 4.10 | 5.11 | 152.68 | 0.001094 | 0.367 | 643.84 | 2105.3 | 2749.1 |\n| 4.20 | 5.21 | 153.42 | 0.001094 | 0.360 | 647.02 | 2102.9 | 2750.0 |\n| 4.30 | 5.31 | 154.14 | 0.001095 | 0.354 | 650.15 | 2100.7 | 2750.8 |\n| 4.40 | 5.41 | 154.85 | 0.001096 | 0.348 | 653.24 | 2098.4 | 2751.6 |\n| 4.50 | 5.51 | 155.55 | 0.001097 | 0.342 | 656.28 | 2096.2 | 2752.4 |\n\n[www.invenoeng.com](www.invenoeng.com)  \n\n| 4.60\u003Cbr>4.70\u003Cbr>4.80\u003Cbr>4.90 | 5.61\u003Cbr>5.71\u003Cbr>5.81\u003Cbr>5.91 | 156.25\u003Cbr>156.93\u003Cbr>157.60\u003Cbr>158.26 | 0.001098\u003Cbr>0.001098\u003Cbr>0.001099\u003Cbr>0.001100 | 0.336\u003Cbr>0.331\u003Cbr>0.325\u003Cbr>0.320 | 659.28\u003Cbr>662.23\u003Cbr>665.15\u003Cbr>668.03 | 2094.0\u003Cbr>2091.8\u003Cbr>2089.6\u003Cbr>2087.5 | 2753.2\u003Cbr>2754.0\u003Cbr>2754.8\u003Cbr>2755.5 |\n| --- | --- | --- | --- | -","cbCaipPJ5p6oL2ZN","https://ap.wps.com/l/cbCaipPJ5p6oL2ZN","pdf",51233,"English","# Metric Steam Tables\n## Parameters and units\n## Property columns (vf, vg, hf, hfg, hg)","[{\"question\":\"What pressure scale does the table start from?\",\"answer\":\"The table uses gauge pressure (barg) in the first column and converts it to absolute pressure (bara) for each row.\"},{\"question\":\"Which thermodynamic quantities are provided for saturated water and steam?\",\"answer\":\"It provides saturation temperature, specific volumes for saturated liquid (vf) and saturated steam (vg), and heat properties: hf, hfg, and total enthalpy hg in kJ/kg.\"},{\"question\":\"How can these tables be used in calculations?\",\"answer\":\"Select the operating gauge pressure to read the matching saturation temperature and enthalpy/heat terms, then use vf/vg and hf/hfg/hg for energy balance, phase-change, and thermodynamic estimation.\"}]","Metric Steam Tables - Table of saturated steam properties | PDF",1791886225]