[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-364028-105":53,"doc-detail-364028-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","itb-024-26-paycor-stadium-south-scoreboard-expansion-bid-package-2-addendum-1","ITB# 024-26 - Paycor Stadium South Scoreboard Expansion - Bid Package 2 - Addendum 1","","Bid Package 2: MEP and Video Board addendum 1 for the Paycor Stadium South Scoreboard Expansion project, dated April 3rd, 2026. Provides engineer estimate totals for associated trade contracts, lists required attachments including security information, pre-bid agenda and sign-in sheets, and multiple tower crane and roof protection items. Includes revised drawings for electrical power plans, electrical single line diagrams, and specifies project manual revision sections. Contains a Q&A section addressing scope clarification topics such as plaza level weight capacity, tower crane and operator provisions, emergency power (deferred to addendum 2), fire alarm integration, system extension responsibilities, speaker modification, and alternate allowances.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":36,"@type":70,"position":76},"https://docshare.wps.com/template/forms/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/itb-024-26-paycor-stadium-south-scoreboard-expansion-bid-package-2-addendum-1/364028/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/itb-024-26-paycor-stadium-south-scoreboard-expansion-bid-package-2-addendum-1/364028.png","ImageObject",442,249,{"name":88,"@type":89},"moss~","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-23","2026-09-23",true,{"@type":98,"interactionType":99,"userInteractionCount":47},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What are the engineer estimate totals for the associated trade contracts (TC-03 to TC-05) and the BP# 3 total?","Question",{"text":108,"@type":109},"The addendum lists TC-03 Electric total as $2,265,864, TC-04 Scoreboard total as $4,827,800, and TC-05 Plumbing total as $42,117, with BP# 3 total of $7,135,781.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"Where is the plaza level weight capacity information referenced, and what are the delivery/unload capacities by area?",{"text":113,"@type":109},"The answer directs readers to the Tower Crane Plan attachment. It states the delivery path/orange area can handle 100 PSF or 45,000 lbs, and the unload & skate path/purple area can handle 100 PSF.",{"name":115,"@type":106,"acceptedAnswer":116},"How is the scoreboard emergency power requirement addressed in this addendum?",{"text":117,"@type":109},"Emergency power needs to be provided to the scoreboard are deferred and answered in Addendum #2.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},364028,1791332742,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":35,"category_name":36,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":47,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":141},962090895452,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","ITB\\# 024-26  \nPaycor Stadium South Scoreboard Expansion  \nBid Package 2: MEP and Video Board  \nAddendum 1  \nApril 3rd, 2026  \nTo All Registered Vendors:  \nNOTE:  \nEngineer Estimate breakdowns for associated Trade Contracts as follows:  \nTC-03 Electric $2,152,364 + $113,500 Allowance Total: $2,265,864  \nTC-04 Scoreboard $4,587,800 + $240,000 Allowance Total: $4,827,800  \nTC-05 Plumbing $37,117 + $5,000 Allowance Total: $42,117  \nBP\\# 3 Total: $7,135,781  \nInclude the following:  \n▪ Attachment 1-PBSL Security Information  \n▪ Attachment 2-Pre-Bid Conference Agenda & Sign-In Sheets  \n▪ Attachment 3-XBE Pre-Bid Meeting Vendor Information Form  \n▪ Attachment 4 – Tower Crane Data & Layout  \n▪ Attachment 5 – Roof Protection Plan  \n▪ Questions & Answers – Review for clarification on the scope of work  \nRevised Drawings:  \n▪ E100 – Electrical Power Plan – Demolition  \no Added Keynote 9 regarding 480V, 175A spare feed that was abandoned in 215 that is now being shown as being reconnected for any emergency needs including a section of the scoreboard for messaging.  \n▪ E200 – Electrical Power Plan – New Work  \no Added section showing routing for alternate work in providing additional power to structure  \n▪ E201 – Electrical Power Plan – New Work  \no Revised drawing to show 1600A Distribution Panel moved to substation room where it should be. This work is now identified as required under both Alternate \\#1 and Alternate \\#2.  \n▪ Electrical Bid Alternate \\#1: 1600A Dist. Panel and 500KVA Scoreboard Power Addition (previously base bid).  \n▪ Electrical Bid Alternate \\#2: 1600A Dist. Panel and 300 KVA Scoreboard Power Addition.  \n▪ E203 – Electrical – Power Plan – New Work – Drawing Added  \no Provides location and routing for alternate work in providing additional power to structure.  \n▪ E600 – Electrical Single Line Diagrams  \no Added partial single line for previously abandoned 480V, 175A spare feeder.  \n▪ E601 – Electrical Single Line Diagrams  \no Updated partial single lines to correspond with Alternate \\#1 and Alternate \\#2 (see changes to sheet E201)  \nProject Manual Revisions:  \n00 10 00.4  \n00 73 19a  \n27 41 16  \nQuestions and Answers:  \nBid Form  \nMesser Safety Healthy and Environmental Requirements Integrated Audio-Video Systems  \nReview for clarification on the scope of work  \nQ: What is the weight capacity of the Plaza Level?  \nA: Refer to Tower Crane Plan attachment. Delivery path (orange), unload & skate path (purple) to be hoisted. Orange path / area is capable of 100PSF or 45,000lbs. Purple path / area is capable of 100 PSF.  \nDesign live load for existing public plaza structure is 100psfor 48,000lb fire truck. Do not overload Placing material or equipment on existing slabs is only permitted after THP review and approval. Trade Contractors to provide all documentation and information necessary for THP review.  \nQ: Will CM provide Swing Stage for unloading lifts at the top of the scoreboard?  \nA: A Tower Crane and Operator will be provided by the Construction Manager for the use of the South Scoreboard Expansion Project. The Tower Crane will be capable of reaching the full score board. Review data sheets for capacities, layout, etc. in Tower Crane Plan. Operator will be included by Construction Manager  \n▪ Crane Model: Terex SK 575-32  \nTrade Contractors must include all other hoisting/rigging required to complete the work. Any additional cranes/hoisting required for moving material out of reach of the tower crane to be included by this Trade Contractor. Trade Contractors shall include all unloading, distribution, staging, hoisting, rigging, scaffolding, platforms, ladders, planking, guying, sheeting, shoring, bracing, transportation, access for material, equipment and personnel, etc. required to perform this scope of work. Provide proposed hoisting plan with submission of bid.  \nQ: How much emergency power needs to be provided to the scoreboard?  \nA: To be answered in Addendum \\#2  \nQ: Are there drawings for the fire alarm syst","cbCaispU3TZC58Ef","https://ap.wps.com/l/cbCaispU3TZC58Ef","pdf",21747191,135,"English","# Engineer Estimate and Trade Contract Totals\n# Attachments Included\n# Revised Drawings\n## Electrical Power Plans\n## Electrical Single Line Diagrams\n# Project Manual Revisions\n# Questions & Answers","[{\"question\":\"What are the engineer estimate totals for the associated trade contracts (TC-03 to TC-05) and the BP# 3 total?\",\"answer\":\"The addendum lists TC-03 Electric total as $2,265,864, TC-04 Scoreboard total as $4,827,800, and TC-05 Plumbing total as $42,117, with BP# 3 total of $7,135,781.\"},{\"question\":\"Where is the plaza level weight capacity information referenced, and what are the delivery/unload capacities by area?\",\"answer\":\"The answer directs readers to the Tower Crane Plan attachment. It states the delivery path/orange area can handle 100 PSF or 45,000 lbs, and the unload \\u0026 skate path/purple area can handle 100 PSF.\"},{\"question\":\"How is the scoreboard emergency power requirement addressed in this addendum?\",\"answer\":\"Emergency power needs to be provided to the scoreboard are deferred and answered in Addendum #2.\"}]","ITB# 024-26 - Paycor Stadium South Scoreboard Expansion - Bid Package 2 - Addendum 1 | PDF",1790155194,47]