[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-565779-105":53,"doc-detail-565779-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","high-performance-industrialhazardous-led-luminaires-lumen-chart-selection-design-criteria","HIGH PERFORMANCE INDUSTRIAL/HAZARDOUS LED LUMINAIRES - Lumen Chart - Selection & Design Criteria","","High performance industrial and hazardous-location LED luminaires selection guide featuring a lumen chart and mounting-height lumens mapping across highbay, arealight, linear, and floodlight categories. Includes recommended mounting heights, lumen outputs, and corresponding part numbers for various products, with emphasis on hazardous areas and specification needs. Also provides common stocked technical BOM entries with voltage, wattage, lumen, color temperature, and zone requirements, plus expert consultation points and value-focused service statements.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":11,"@type":70,"position":76},"https://docshare.wps.com/template/presentations/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/high-performance-industrialhazardous-led-luminaires-lumen-chart-selection-design-criteria/565779/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/high-performance-industrialhazardous-led-luminaires-lumen-chart-selection-design-criteria/565779.png","ImageObject",442,249,{"name":88,"@type":89},"MrHarris58","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-22","2026-10-13",true,{"@type":98,"interactionType":99,"userInteractionCount":47},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"How does the lumen chart relate mounting height to lumens and part numbers?","Question",{"text":108,"@type":109},"The chart lists recommended mounting heights with corresponding lumen outputs and mapped product/part numbers across categories such as highbay, arealight, linear, and floodlight.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"What information is included in the most commonly stocked technical BOM?",{"text":113,"@type":109},"Each BOM line provides manufacturer, description, part number, and stock status, along with electrical and performance details such as wattage, input voltage range, lumen output, color temperature, and hazardous zone where shown.",{"name":115,"@type":106,"acceptedAnswer":116},"What expert support is offered for selection and design in hazardous locations?",{"text":117,"@type":109},"The document highlights expert consultation for selection and design criteria, focusing on accurate facility system simulations, increased safety and cost savings, and maximizing energy savings while meeting installation requirements.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},565779,1792336259,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":8,"category_name":11,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":47,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":73,"language":135,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":136,"faqs":137,"seo_title":138,"seo_description":61,"update_tm":139,"read_time":9},687212988360,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","HAZARDOUS LOCATION  \nLED LIGHTING EXPERTS  \nPROVIDING SALES AND SUPPORT  \nWITHMILLIONS IN STOCK  \nw w w.proteks c.com  \nDialight  \n# HIGH PERFORMANCEINDUSTRIAL/HAZARDOUSLED LUMINAIRES\n\nLUMEN CHART  \nMounting Recommended  \nHeight Lumens  \nHIGHBAY  \nAREALIGHT  \nLINEAR  \nFLOODLIGHT  \n\n| 8'   | 3500L   | ALD5BC24NNWNGN   | LPD3C4D2P   | X   | X   |\n| --- | --- | --- | --- | --- | --- |\n| 10'   | 4000L   | ALD5BC24NNWNGN  \u003Cbr>ALD5BC26NNWNGN   | LPD3C4D2P  \u003Cbr>LPD3C4M2P   | X   | X   |\n| 12'   | 5000L   | ALD5BC26NNWNGN   | LPD3C4D2P  \u003Cbr>LPD3C4M2P   | X   | X   |\n| 14'   | 6000L   | ALD5BC26NNWNGN   | LPD3C4M2P   | X   | X   |\n| 16'   | 7000L   | ALD5BC27NNWNGN   | LPD3C4M2P   | HED7MC2BNNWNGN   | F1D76B2BDENVGN   |\n| 18'   | 9000L   | ALD5BC27NNWNGN  \u003Cbr>ALD5BC29NNWNGN   | LPD3C4M2P   | HED7MC2CNNWNGN   | F1D76B2BDENVGN   |\n| 20'   | 12000L   | ALD5BC29NNWNGN   | X   | HED7MC2CNNWNGN   | F1D76B2BDENVGN   |\n| 30'   | 18000L   | X   | X   | HED7MC2CNNWNGN   | F1D76B2CDENVGN   |\n| 40'   | 32000L   | X   | X   | HED7MC2ENNWNGN   | F1D76B2FDENVGN   |\n| 50'   | 48000L   | X   | X   | VED7MC2JNNWNGN   | F2D76B2LDENVGN   |\n| 100'   | 72000L   | X   | X   | VED7MC2JNNWNGN   | F2D76B2NDENVGN   |\n\nCSA C1Z1&C1Z2 |10YR WARRANTY |ENERGY EFFICIENT |SIMPLE INSTALLAHON |STOCK  \n# Expert Consultation forSelection &Design Criteriawithin Hazardous Locations\n\nABOUT PROTEK  \nOur primary objective is to always deliver long-term valuefor our customers by leveraging the strength of ourpartners,the dedication and expertise of our people,our stock,and the robustness of our operations.Our promise is to always do what is right in order to exceedexpectations and deliver for our customers-every time.  \n·3D Renderings of Facility SystemWork with our team to produceaccurate site simulations  \n·Increased Safety &Cost SavingEliminate risk and ensure theInstallation meets requirements  \n·Maximize Energy SavingsReduce system overlap withlower power consumption  \nAB:403.668.6869 NE BC:250.277.2552 SK:306.985.0024  \nDialight  \n# HIGH PERFORMANCE\n\nINDUSTRIAL/HAZARDOUS  \n# LED LUMINAIRES\n\nMOST COMMONLY STOCKED TECHNICAL BOM  \n\n| Manufacturer   | Description   | Part No.   | Stock   |\n| --- | --- | --- | --- |\n| Dialight/Protek   | 2'LED Linear,29W,100-277VAC,3850 Lumen,5000K,Zone 2   | LPD3C4D2P   | Yes   |\n| Dialight/Protek   | 4'LED Linear,60W,100-277VAC,7900 Lumen,5000K,Zone 2   | LPD3C4M2P   | Yes   |\n| Dialight/Protek   | Mounting Bracket for above   | LPXW4   | Yes   |\n| Dialight/Protek   | 4'Battery Backup,85W,100-277VAC,7000 Lumen,Zone 2,120min Backup   | LSD3C4MEP   | Yes   |\n| Dialight/Protek   | Mounting Bracket for above   | LSXW4   | Yes   |\n| Dialight/Protek   | LED High Bay,100W,100-277VAC,14,900 Lumen,5000K,Zone 2   | HED7MC2BNNWNGN   | Yes   |\n| Dialight/Protek   | LED High Bay,130W 100-277VAC,19,800 Lumen,5000K,Zone 2   | HED7MC2CNNWNGN   | Yes   |\n| Dialight/Protek   | Swivel Bracket &Cable Gland for above   | HBXW2   | Yes   |\n| Dialight/Protek   | 2\"Stanchion Mounting Slip Fitter w/Built in JB   | HZXSTAN200S   | Yes   |\n| Dialight/Protek   | 2'LED Linear,34W,100-277VAC,3600 Lumen,Zone 1   | LSC3C4D3GEX   | Yes   |\n| Dialight/Protek   | 4'LED Linear,68W,100-277VAC,7250 Lumen,Zone 1   | LSC3C4M3GEX   | Yes   |\n| Dialight/Protek   | Mounting Bracket for above   | LSXW5   | Yes   |\n| Dialight/Protek   | LED Highbay,129W,18600,5000K,Zone 1   | HEC7MC2CNNWNGN   | No   |\n| Dialight/Protek   | LED flood light,81W,12500 Lumen,5000K,Zone 2,100-277VAC   | F1D76B2BDENVGN   | No   |\n| Dialight/Protek   | LED flood light,124W,18000 Lumen,5000K,Zone 2,100-277VAC   | F1D76B2CDENVGN   | Yes   |\n| Dialight/Protek   | LED flood light,175W,23600 Lumen,5000K,Zone 2,100-277VAC   | F1D76B2EDENVGN   | No   |\n| Dialight/Protek   | 23/8\"Tennon Topper for above   | FLX-1TPT-20DB   | Yes   |\n| Dialight/Protek   | LED Area Light,5000k,100-277VAC,  \u003Cbr>pendant mount,30W,3900 Lumen,Zone 2   | ALD5BC24NNWNGN   | Yes   |\n| Dialight/Protek   | LED Area Light,5000k,100-277VAC,  \u003Cbr>p","cbCaimSuibJi6Hkn","https://ap.wps.com/l/cbCaimSuibJi6Hkn","pdf",5192748,"English","# Lumen Chart\n## Mounting Recommended Height & Lumens\n## Highbay / Arealight / Linear / Floodlight\n# Most Commonly Stocked Technical BOM\n## Part Numbers & Stock Availability\n# Expert Consultation for Selection & Design Criteriawithin Hazardous Locations","[{\"question\":\"How does the lumen chart relate mounting height to lumens and part numbers?\",\"answer\":\"The chart lists recommended mounting heights with corresponding lumen outputs and mapped product/part numbers across categories such as highbay, arealight, linear, and floodlight.\"},{\"question\":\"What information is included in the most commonly stocked technical BOM?\",\"answer\":\"Each BOM line provides manufacturer, description, part number, and stock status, along with electrical and performance details such as wattage, input voltage range, lumen output, color temperature, and hazardous zone where shown.\"},{\"question\":\"What expert support is offered for selection and design in hazardous locations?\",\"answer\":\"The document highlights expert consultation for selection and design criteria, focusing on accurate facility system simulations, increased safety and cost savings, and maximizing energy savings while meeting installation requirements.\"}]","HIGH PERFORMANCE INDUSTRIAL/HAZARDOUS LED LUMINAIRES - Lumen Chart - Selection & Design Criteria | PDF",1791857996]