[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-detail-167034-en":3,"doc-seo-167034-105":30,"detail-sidebar-cat-1-en-105":95},{"code":4,"msg":5,"data":6},0,"success",{"doc_id":7,"user_id":8,"nickname":9,"user_avatar":10,"doc_module":11,"category_id":12,"category_name":13,"doc_title":14,"doc_description":15,"doc_content":16,"file_id":17,"file_url":18,"file_type":19,"file_size":20,"view_count":4,"is_deleted":4,"is_public":11,"is_downloadable":11,"audit_status":11,"page_count":21,"language":22,"language_code":23,"site_id":24,"html_lang":23,"table_of_contents":25,"faqs":26,"seo_title":27,"seo_description":15,"update_tm":28,"read_time":29},167034,13056712833777,"Paura","https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0",1,17,"Forms","Henrico County No Impact Statement - Peak Offset Analysis Template and Instructions","Henrico County requires a No-Rise Certification for development within floodplains, supported by technical data. For certain projects, a No Impact Statement can justify no floodplain impact using commonsense engineering approaches and high-level calculations. The template provides required report sections for a Peak Offset Analysis, guides engineers on which items to remove when not applicable, and instructs updating the table of contents and appendix handling for the final PDF submission.","Henrico County\u000bNo Impact Statement: Peak Offset Analysis\u000bTemplate and Instructions\n(to support a No-Rise Certification)\nA No-Rise Certification is required for all development in Henrico County floodplains. No-Rise Certifications must be supported by technical data, and for some projects, a No Impact Statement may be used as this technical data. A No Impact Statement uses commonsense engineering approaches and high level calculations as justification of no impact to the floodplain.\nNo Impact Statement Template\nA No Impact Statement template for a Peak Offset Analysis is included at the end of this section for consideration and use by the certifying engineer for a development project.\nNo Impact Statement Template Directions\nThe No Impact Statement (Peak Offset Analysis) template includes all sections that must be included in a report for review. This template can be incorporated into a different format that uses your company name, logo, design, etc., but the headings and general layout should remain the same.\nSome sections may not be applicable to all project types. These items have been labeled with “if applicable” and should be removed from the report if they are not applicable to the project.\nThe Table of Contents for the template is linked to the headings. This table must be updated when the report is complete, so the table accurately reflects the final headings and page numbers.\nAppendix titles have been included in the template report. Several of the appendices will be large documents from other programs. These do not need to be added to the Word document. Instead, they should be added to the final PDF version of the report.\nApplicable Project Types\nCertifying engineers should review the \u0013 HYPERLINK \"https://henrico.us/pdfs/works/design/flood/HenricoFloodplainManual_FINAL.pdf\" \u0014Henrico County Floodplain Technical Guidance Manual, specifically Section 5.A.2 and Section 6.3.G\u0015, to determine if the proposed project may be eligible to use a No Impact Statement (Peak Offset Analysis) to support the No-Rise Certificate.\nTHIS PAGE SHOULD BE DELETED PRIOR TO SUBMISSION\nNo Impact Statement: Peak Offset Analysis for:\u000b[Project Name]\n[Stream Name(s)]\nHenrico County, VA\n[Report Date]\n[Report Revision Date (if applicable)]\nPrepared By:\n[Engineer(s)’s Name]\n[Engineer(s)’s Email Address]\n[Engineer(s)’s Phone Number]\n[Company Name]\n[Company Address]\n[Insert PE Seal & Signature]\n\u0003Table of Contents\n\u0013 TOC \\o \"1-3\" \\h \\z \\u \u0014\u0013 HYPERLINK \\l \"_Toc170740279\" \u00141.\tProject Description\t\u0013 PAGEREF _Toc170740279 \\h \u00141\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740280\" \u00141.1.\tNarrative Statement\t\u0013 PAGEREF _Toc170740280 \\h \u00141\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740281\" \u00141.2.\tDetermination of Floodplains\t\u0013 PAGEREF _Toc170740281 \\h \u00141\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740282\" \u00141.3.\tNo Rise / Project Impact Statement\t\u0013 PAGEREF _Toc170740282 \\h \u00141\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740283\" \u00142.\tSupporting Documentation\t\u0013 PAGEREF _Toc170740283 \\h \u00141\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740284\" \u00142.1.\tPlan Sheets\t\u0013 PAGEREF _Toc170740284 \\h \u00141\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740285\" \u00142.2.\tPeak Flow Calculations\t\u0013 PAGEREF _Toc170740285 \\h \u00141\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740286\" \u00142.2.1.\tHydrologic Model Output\t\u0013 PAGEREF _Toc170740286 \\h \u00141\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740287\" \u00142.3.\tMaps\t\u0013 PAGEREF _Toc170740287 \\h \u00142\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740288\" \u00142.3.1.\tExisting and Proposed Drainage Area Maps\t\u0013 PAGEREF _Toc170740288 \\h \u00142\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740289\" \u00142.3.2.\tExisting and Proposed Land Use Maps\t\u0013 PAGEREF _Toc170740289 \\h \u00142\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740290\" \u00142.4.\tDetail or Cross-Section Drawings (if applicable)\t\u0013 PAGEREF _Toc170740290 \\h \u00142\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740291\" \u0014Appendix 1.\tPlan Sheets\t\u0013 PAGEREF _Toc170740291 \\h \u0014i\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740292\" \u0014Appendix 2.\tPeak Flow Calculations\t\u0013 PAGEREF _Toc170740292 \\h \u0014i\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740293\" \u0014Appendix 3.\tHydrology Model Outputs\t\u0013 PAGEREF _Toc170740293 \\h \u0014i\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc170740294\" \u0014Appendix 4.\tExisting Drainage Area Map\t\u0013 PAGEREF _Toc170740294 \\h \u0014i\u0015\u0015\n\u0013 HYPERL","cbCaigMnqg9nBRUv","https://ap.wps.com/l/cbCaigMnqg9nBRUv","docx",101743,6,"English","en",105,"# Project Description\n## Narrative Statement\n## Determination of Floodplains\n## No Rise / Project Impact Statement\n# Supporting Documentation\n## Plan Sheets\n## Peak Flow Calculations\n## Hydrologic Model Output\n## Maps\n## Existing and Proposed Drainage Area Maps\n## Existing and Proposed Land Use Maps\n## Detail or Cross-Section Drawings (if applicable)\n# Appendices\n## Appendix 1. Plan Sheets\n## Appendix 2. Peak Flow Calculations\n## Appendix 3. Hydrology Model Outputs\n## Appendix 4. Existing Drainage Area Map\n## Appendix 5. Proposed Drainage Area Map\n## Appendix 6. Existing Land Use/Cover Map\n## Appendix 7. Proposed Land Use/Cover Map\n## Appendix 8. Detail or Cross-Section Drawings (if applicable)","[{\"question\":\"When is a No Impact Statement used instead of other technical support for a No-Rise Certification?\",\"answer\":\"No-Rise Certifications are required for development in Henrico County floodplains, and some projects may use a No Impact Statement as the supporting technical data.\"},{\"question\":\"What engineering basis does the No Impact Statement rely on for a Peak Offset Analysis?\",\"answer\":\"The justification uses commonsense engineering approaches and high-level calculations to support a finding of no impact to the floodplain.\"},{\"question\":\"What are certifying engineers expected to check before using the template for a project?\",\"answer\":\"Engineers should review the Henrico County Floodplain Technical Guidance Manual, specifically Section 5.A.2 and Section 6.3.G, to determine eligibility for using a No Impact Statement (Peak Offset Analysis).\"},{\"question\":\"How should the template’s Table of Contents and appendices be handled for the final report?\",\"answer\":\"The Table of Contents linked to headings must be updated after completion so it reflects final headings and page numbers, and large appendices from other programs should be added to the final PDF rather than inserted into the Word document.\"}]","Henrico County No Impact Statement - Peak Offset Analysis Template and Instructions | DOCX",1788206824,2,{"code":4,"msg":31,"data":32},"ok",{"site_id":24,"language":23,"slug":33,"title":14,"keywords":34,"description":15,"schema_data":35,"social_meta":90,"head_meta":92,"extra_data":94,"updated_unix":28},"henrico-county-no-impact-statement-peak-offset-analysis-template-and-instructions","",{"@graph":36,"@context":89},[37,53,68],{"@type":38,"itemListElement":39},"BreadcrumbList",[40,44,47,50],{"item":41,"name":42,"@type":43,"position":11},"https://docshare.wps.com","Home","ListItem",{"item":45,"name":46,"@type":43,"position":29},"https://docshare.wps.com/template/","Template",{"item":48,"name":13,"@type":43,"position":49},"https://docshare.wps.com/template/forms/",3,{"item":51,"name":14,"@type":43,"position":52},"https://docshare.wps.com/template/henrico-county-no-impact-statement-peak-offset-analysis-template-and-instructions/167034/",4,{"url":51,"name":14,"@type":54,"author":55,"headline":14,"publisher":57,"fileFormat":60,"inLanguage":23,"description":15,"dateModified":61,"datePublished":62,"encodingFormat":60,"isAccessibleForFree":63,"interactionStatistic":64},"DigitalDocument",{"name":9,"@type":56},"Person",{"url":41,"name":58,"@type":59},"DocShare","Organization","application/vnd.openxmlformats-officedocument.wordprocessingml.document","2026-09-01","2026-08-31",true,{"@type":65,"interactionType":66,"userInteractionCount":11},"InteractionCounter",{"@type":67},"ViewAction",{"@type":69,"mainEntity":70},"FAQPage",[71,77,81,85],{"name":72,"@type":73,"acceptedAnswer":74},"When is a No Impact Statement used instead of other technical support for a No-Rise Certification?","Question",{"text":75,"@type":76},"No-Rise Certifications are required for development in Henrico County floodplains, and some projects may use a No Impact Statement as the supporting technical data.","Answer",{"name":78,"@type":73,"acceptedAnswer":79},"What engineering basis does the No Impact Statement rely on for a Peak Offset Analysis?",{"text":80,"@type":76},"The justification uses commonsense engineering approaches and high-level calculations to support a finding of no impact to the floodplain.",{"name":82,"@type":73,"acceptedAnswer":83},"What are certifying engineers expected to check before using the template for a project?",{"text":84,"@type":76},"Engineers should review the Henrico County Floodplain Technical Guidance Manual, specifically Section 5.A.2 and Section 6.3.G, to determine eligibility for using a No Impact Statement (Peak Offset Analysis).",{"name":86,"@type":73,"acceptedAnswer":87},"How should the template’s Table of Contents and appendices be handled for the final report?",{"text":88,"@type":76},"The Table of Contents linked to headings must be updated after completion so it reflects final headings and page numbers, and large appendices from other programs should be added to the final PDF rather than inserted into the Word document.","https://schema.org",{"og:url":51,"og:type":91,"og:title":14,"og:site_name":58,"og:description":15},"article",{"robots":93,"canonical":51},"index,follow",{"doc_id":7,"site_id":24},{"code":4,"msg":5,"data":96},[97,102,107,112,117,122,125,130,135],{"id":98,"doc_module":11,"doc_module_name":46,"category_name":99,"show_sort_weight":100,"slug":101},11,"Presentations",90,"presentations",{"id":103,"doc_module":11,"doc_module_name":46,"category_name":104,"show_sort_weight":105,"slug":106},12,"Resumes",80,"resumes",{"id":108,"doc_module":11,"doc_module_name":46,"category_name":109,"show_sort_weight":110,"slug":111},14,"Invoices",70,"invoices",{"id":113,"doc_module":11,"doc_module_name":46,"category_name":114,"show_sort_weight":115,"slug":116},15,"Posters",60,"posters",{"id":118,"doc_module":11,"doc_module_name":46,"category_name":119,"show_sort_weight":120,"slug":121},16,"Social Media",50,"social-media",{"id":12,"doc_module":11,"doc_module_name":46,"category_name":13,"show_sort_weight":123,"slug":124},40,"forms",{"id":126,"doc_module":11,"doc_module_name":46,"category_name":127,"show_sort_weight":128,"slug":129},18,"Letters",30,"letters",{"id":131,"doc_module":11,"doc_module_name":46,"category_name":132,"show_sort_weight":133,"slug":134},21,"Paper Templates",5,"papers-templates",{"id":136,"doc_module":11,"doc_module_name":46,"category_name":137,"show_sort_weight":4,"slug":138},158,"General","general-158"]