[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-563124-105":53,"doc-detail-563124-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","hawk-3-operators-manual-advanced-digital-controller","Hawk 3 - Operator’s Manual - Advanced Digital Controller","","Hawk 3 H335 and H345 are 3 1/2 digit and 4 1/2 digit advanced digital controller units, documented with an operator’s manual focused on safe setup and correct operation. The manual explains warning and caution guidance for hazardous operating conditions and emphasizes reading instructions fully before measurements. It provides technical assistance contact details, warranty and return terms, and a structured outline covering installation and wiring, programming, key operations, input/output cards, display and keypad controls, and RS-485 communications, plus ordering information.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/hawk-3-operators-manual-advanced-digital-controller/563124/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/hawk-3-operators-manual-advanced-digital-controller/563124.png","ImageObject",442,249,{"name":88,"@type":89},"How to eat","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-27","2026-10-12",true,{"@type":98,"interactionType":99,"userInteractionCount":15},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What safety guidance does the Hawk 3 operator’s manual emphasize before measurements?","Question",{"text":108,"@type":109},"It stresses that warning instructions must be adhered to and that the manual must be read carefully and completely before making any measurements. It also notes that careless use can still make an instrument unsafe despite design protections.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"What is the recommended programming order for advanced features on the Hawk 3?",{"text":113,"@type":109},"The manual recommends: 1) Decimal Point, 2) Linearization (AKA Scaling), 3) Set Point/Relay Control (if applicable), and 4) Analog output or other applicable controls.",{"name":115,"@type":106,"acceptedAnswer":116},"How does programming mode exit to ensure changes are saved?",{"text":117,"@type":109},"The manual states that exiting the programming menu by backing out of submenus one level at a time and returning to run mode from the main menu assures all changes are saved.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},563124,1792122412,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":15,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":37,"language":135,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":136,"faqs":137,"seo_title":138,"seo_description":61,"update_tm":139,"read_time":20},962093541613,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Hawk 3  \nH335 and H345  \n3 1/2 Digit and 4 1/2 Digit Advanced Digital Controller  \nOperator’s Manual  \nAbout this Manual  \nTo the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument in compliance  \nNotes and Safety Information  \nThis Operator’s Manual contains warning headings that alert the user to check for hazardous  \nthe safety of operating performance of this instrument, these instructions must be adhered to.  \nWarning, refer to accompanying documents.  \nAttention, consulter les documents d’accompagnement.  \nCaution, risk of electric shock. Attention, risque de choc électrique.  \nThis instrument is designed to prevent accidental shock to the operator when properly used. However, no engineering design can render safe an instrument which is used carelessly. Therefore, this manual must be read carefully and completely before making any measurements. Failure to follow directions can result in a serious or fatal accident.  \nTechnical Assistance  \nSIMPSON ELECTRIC COMPANY offers assistance Monday through Friday 8:00 am to 4:30 pm Central Time by contacting Technical Support or Customer Service at (715) 588-3311.  \nInternet: [http://www.simpsonelectric.com](http://www.simpsonelectric.com)  \nWarranty and Returns  \nSIMPSON ELECTRIC COMPANY warrants each instrument and other articles manufactured by it tobe free from defects in material and workmanship under normal use and service, its obligation under this warranty being limited to making good at its factory or other article of equipment which shall within one (2) year after delivery of such instrument or other article of equipment to the original purchaser be returned intact to it, or to one of its authorized service centers, with transportation charges prepaid, and which its examination shall disclose to its satisfaction to have been thus defective; this warranty being expressly in lieu of all other warranties expressed or implied and of all other obligations or liabilities on its part, and SIMPSON ELECTRIC COMPANY neither assumes nor authorizes any other persons to assume for it any other liability in connection with the sales of its products.  \nThis warranty shall not apply to any instrument or other article of equipment which shall have been repaired or altered outside the SIMPSON ELECTRIC COMPANY factory or authorized service centers, nor which has been subject to misuse, negligence or accident, incorrect wiring by others, or installation or use not in accord with instructions furnished by the manufacturer.  \n\n| Contents |  |  |  |\n| --- | --- | --- | --- |\n| Quick Start Reference for Typical Control Instrument Features |  |  | 5 |\n|  | Installation and Wiring |  | 5 |\n|  | Programming |  | 5 |\n|  |  | Basic Key Operation for Programming | 5 |\n|  |  | Decimal Point | 5 |\n|  |  | Linearization | 6 |\n|  |  | Set Points & Relays | 6 |\n| 1. INTRODUCTION |  |  | 8 |\n|  | 1.1 | General Description | 8 |\n|  | 1.2 | | 8 |\n| 2. INSTALLATION AND PANEL CUTOUT |  |  | 10 |\n|  | 2.1 | Mounting Requirements | 10 |\n|  | 2.2 | Engineering Label Placement | 10 |\n|  | 2.3 | Removing / Installing Modules | 11 |\n| 3. INPUT CARDS |  |  | 11 |\n|  | 3.1 | Low Current | 11 |\n|  | 3.2 | High Current | 12 |\n|  | 3.3 | Volts | 13 |\n|  | 3.4 | Resistance | 14 |\n|  | 3.5 | Relay Cards | 14 |\n|  | 3.6 | Power Supply Cards | 15 |\n| 4. OUTPUT CARDS |  |  | 15 |\n|  | 4.1 | Excitation | 16 |\n| 5. DISPLAY AND KEYPAD CONTROLS |  |  | 17 |\n|  | 5.1 | Operating the Keys | 17 |\n|  |  | 5.1.1 Run Mode | 17 |\n|  |  | 5.1.2 Program Mode | 17 |\n|  |  | 5.1.3 Edit Mode | 17 |\n|  |  | 5.1.4 Reset to Factory Defaults | 17 |\n|  |  | 5.1.5 Password Reset | 17 |\n\n\n| Contents (Con’t) |  |  |  |\n| --- | --- | --- | --- |\n| 6. PROGRAMMING |  |  | 18 |\n|  | 6.1 | Programming Order | 18 |\n|  | 6.2 | General Programming Guidelines | 18 |\n|  | 6.3 | Programming Menu | 18 |\n|  | 6.4 | Setpoint and Relay ","cbCaia3OXEjE9Ts3","https://ap.wps.com/l/cbCaia3OXEjE9Ts3","pdf",1109984,"English","# About this Manual\n# Notes and Safety Information\n# Technical Assistance\n# Warranty and Returns\n# Quick Start Reference for Typical Control Instrument Features\n## Installation and Wiring\n## Programming\n## Basic Key Operation for Programming\n## Decimal Point\n## Linearization\n## Set Points & Relays\n# 1. INTRODUCTION\n# 2. INSTALLATION AND PANEL CUTOUT\n## 2.1 Mounting Requirements\n## 2.2 Engineering Label Placement\n## 2.3 Removing / Installing Modules\n# 3. INPUT CARDS\n## 3.1 Low Current\n## 3.2 High Current\n## 3.3 Volts\n## 3.4 Resistance\n## 3.5 Relay Cards\n## 3.6 Power Supply Cards\n# 4. OUTPUT CARDS\n## 4.1 Excitation\n# 5. DISPLAY AND KEYPAD CONTROLS\n## 5.1 Operating the Keys\n## 5.1.1 Run Mode\n## 5.1.2 Program Mode\n## 5.1.3 Edit Mode\n## 5.1.4 Reset to Factory Defaults\n## 5.1.5 Password Reset\n# 6. PROGRAMMING\n## 6.1 Programming Order\n## 6.2 General Programming Guidelines\n## 6.3 Programming Menu\n## 6.4 Setpoint and Relay Control\n## 6.5 Display Control\n## 6.6 Measurement Control\n## 6.7 Output Control\n## 6.8 Scaling / Linearization Control\n## 6.9 Password\n# 7. RS-485 COMMUNICATIONS\n## 7.1 RS-485 Command Structure\n## 7.3 Address\n## 7.4 Valid Commands\n## 7.5 Examples\n# 8. FLOW CHART\n# 9. ORDERING INFORMATION","[{\"question\":\"What safety guidance does the Hawk 3 operator’s manual emphasize before measurements?\",\"answer\":\"It stresses that warning instructions must be adhered to and that the manual must be read carefully and completely before making any measurements. It also notes that careless use can still make an instrument unsafe despite design protections.\"},{\"question\":\"What is the recommended programming order for advanced features on the Hawk 3?\",\"answer\":\"The manual recommends: 1) Decimal Point, 2) Linearization (AKA Scaling), 3) Set Point/Relay Control (if applicable), and 4) Analog output or other applicable controls.\"},{\"question\":\"How does programming mode exit to ensure changes are saved?\",\"answer\":\"The manual states that exiting the programming menu by backing out of submenus one level at a time and returning to run mode from the main menu assures all changes are saved.\"}]","Hawk 3 - Operator’s Manual - Advanced Digital Controller | PDF",1791811627]