[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-253604-105":53,"doc-detail-253604-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","fire-safety-manual-inspection-forms-automatic-sprinkler-systems","Fire Safety Manual Inspection Forms - Automatic Sprinkler Systems","","Fire safety manual inspection forms for automatic sprinkler systems document recurring inspection activities across weekly, monthly, quarterly, semi-annual, and annual intervals. Each form standardizes fields for inspector identification, valve/seal or lock status, sprinkler condition and storage clearances, and required pressure readings in psi. Where applicable, the forms also guide system-specific tests such as main drain tests, alarm valve leak checks, priming level verification, low air pressure alarm operation, and flow-alarm testing, including instructions for recording notes and corrective actions.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":36,"@type":70,"position":76},"https://docshare.wps.com/template/forms/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/fire-safety-manual-inspection-forms-automatic-sprinkler-systems/253604/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/fire-safety-manual-inspection-forms-automatic-sprinkler-systems/253604.png","ImageObject",442,249,{"name":88,"@type":89},"วิน","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-31","2026-09-13",true,{"@type":98,"interactionType":99,"userInteractionCount":25},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What information is recorded in the automatic sprinkler system inspection forms?","Question",{"text":108,"@type":109},"Each form captures the inspection date, inspector identification, and key system status fields such as valve seal/lock conditions and whether sprinklers are in acceptable condition. Many forms also require recording pressure readings in psi and documenting significant notes.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"What is the action required when pressure loss exceeds the specified threshold?",{"text":113,"@type":109},"The forms instruct that a loss of more than 10% should be investigated. Any findings and relevant notes are then recorded for follow-up and corrective action.",{"name":115,"@type":106,"acceptedAnswer":116},"What tests are included in the quarterly inspection form for wet and dry pipe systems?",{"text":117,"@type":109},"The quarterly form includes a main drain test procedure and testing of water flow alarms by using the inspectors test valve. For dry pipe systems, it also covers checking dry valve priming water level, confirming low air pressure alarm activation, and performing dry pipe system flow-alarm testing.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},253604,1789267252,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":35,"category_name":36,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":25,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":15,"language":135,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":136,"faqs":137,"seo_title":138,"seo_description":61,"update_tm":125,"read_time":79},2336475104736,"https://ap-avatar.wpscdn.com/avatar/22000c4c5e0e5b17e70?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786591360781797222","FIRE SAFETY MANUAL INSPECTION FORMS.............................................................48  \nFORM F-1 AUTOMATIC SPRINKLER SYSTEMS– WEEKLY INSPECTION ..............................48  \nFORM F-2 AUTOMATIC SPRINKLER SYSTEMS– MONTHLY INSPECTION ............................49  \nFORM F-3 AUTOMATIC SPRINKLER SYSTEMS– QUARTERLY INSPECTION AND TESTS ......50  \nFORM F-4 AUTOMATIC SPRINKLER SYSTEMS– SEMI-ANNUAL INSPECTION AND TESTS...51  \nFORM F-5 AUTOMATIC SPRINKLER SYSTEMS– ANNUAL INSPECTION, TESTS & MAINT ..52 FORM F-6 AUTOMATIC SPRINKLER SYSTEMS– 5-YEAR INSPECTION ................................53  \nFORM F-7 STANDPIPE AND HOSE SYSTEMS– STANDPIPE HYDROSTATIC & FLOW TEST ..54 FORM F-8 STANDPIPE AND HOSE SYSTEMS– ANNUAL INSPECTION & MAINTENANCE .....55  \nFORM F-9 HYDRANT-INSPECTIONS– SEMI-ANNUAL INSPECTION FOR DRY BARREL HYDRANTS, ANNUAL INSPECTION FOR WET BARREL HYDRANTS ....................56  \nFORM F-10 FIRE PUMPS– MONTHLY INSPECTION ............................................................57  \nFORM F-11 FIRE PUMPS– MONTHLY TESTS .....................................................................58  \n\n| \u003Cbr>AUTOMATIC SPRINKLER SYSTEMS FORM F-1\u003Cbr>Weekly Inspection\u003Cbr>SYSTEM  \u003Cbr>This form covers a 6-month period |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1. Date of inspection.\u003Cbr>2. Inspector’s name, initials or badge number.\u003Cbr>3. If valves are sealed, note “yes” in this block. If any are\u003Cbr>not sealed, reseal and note “resealed” in this block.\u003Cbr>4. If all sprinklers are in good condition and storage is\u003Cbr>maintained at least 18 in. below the sprinklers, note\u003Cbr>“yes” in this block. If not, see that corrections are\u003Cbr>made and briefly describe under “notes.” |  |  |  |  | 5-8. Record pressure readings (psi) . A loss of more than 10% should be investigated.\u003Cbr>9. Record any notes about the system which the inspector believes to be significant. Use separate sheet if needed. |  |  |  |\n| 1\u003Cbr>DATE | 2\u003Cbr>INSPECTOR | 3\u003Cbr>VALVE(S) SEALED | 4\u003Cbr>SPRINKLERS OK | 5\u003Cbr>ALARM\u003Cbr>VALVE\u003Cbr>OK | 6\u003Cbr>DRY PIPE\u003Cbr>VALVE\u003Cbr>Air Water\u003Cbr>Pres. Pres. | 7\u003Cbr>PREACTION VALVE Air Water\u003Cbr>Pres. Pres. | 8\u003Cbr>DELUGE VALVE WATER PRESSURE | 9\u003Cbr>NOTES |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n\nFLORIDA ATLANTIC UNIVERSITY, FIRE SAFETY MANUAL 48  \n\n| |  | AUTOMATIC SPRINKLER SYSTEMS FORM F-2\u003Cbr>Monthly Inspection\u003Cbr>SYSTEM   |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1. Date of inspection.\u003Cbr>2. Inspector’s name, initials or badge number.\u003Cbr>3. If fire department connections are unobstructed and in good condition, note “OK” in block. If not, see that corrections are made and briefly describe under“notes.”\u003Cbr>4. If valves are locked, note “yes” in this block. If any are not locked, relock and note “relocked” in this block.\u003Cbr>5. Inspect alarm valves to assure no leakage from retard chamber or alarm drains. |  |  |  |  | 6. Assure there is proper number and type of sprinklersand a sprinkler wrench.\u003Cbr>7. Check for phys ical damage and that electrical connections are secure .\u003Cbr>8. Record pressure readings (psi) . A loss of more than 10% should be investigated.\u003Cbr>9. Record any notes about the system which the inspector believes to be significant. Place a number in this block and number the corresponding note at the end of the inspection form. |  |  |  |  |\n| 1\u003Cbr>DATE | 2\u003Cbr>INSPECTOR | 3\u003Cbr>FIRE DEPARTMENT CONNECTIONS | 4\u003Cbr>VALVES","cbCaioaFLIefaJPm","https://ap.wps.com/l/cbCaioaFLIefaJPm","pdf",74885,"English","# Automatic Sprinkler Systems Inspection Forms\n## Form F-1 Weekly Inspection\n## Form F-2 Monthly Inspection\n## Form F-3 Quarterly Inspection and Tests\n## Form F-4 Semi-Annual Inspection and Tests\n## Form F-5 Annual Inspection, Tests & Maintenance\n## Form F-6 5-Year Inspection\n# Additional System Forms\n## Form F-7 Standpipe and Hose Systems\n## Form F-8 Standpipe and Hose Systems\n## Form F-9 Hydrant Inspections\n## Form F-10 Fire Pumps Monthly Inspection\n## Form F-11 Fire Pumps Monthly Tests","[{\"question\":\"What information is recorded in the automatic sprinkler system inspection forms?\",\"answer\":\"Each form captures the inspection date, inspector identification, and key system status fields such as valve seal/lock conditions and whether sprinklers are in acceptable condition. Many forms also require recording pressure readings in psi and documenting significant notes.\"},{\"question\":\"What is the action required when pressure loss exceeds the specified threshold?\",\"answer\":\"The forms instruct that a loss of more than 10% should be investigated. Any findings and relevant notes are then recorded for follow-up and corrective action.\"},{\"question\":\"What tests are included in the quarterly inspection form for wet and dry pipe systems?\",\"answer\":\"The quarterly form includes a main drain test procedure and testing of water flow alarms by using the inspectors test valve. For dry pipe systems, it also covers checking dry valve priming water level, confirming low air pressure alarm activation, and performing dry pipe system flow-alarm testing.\"}]","Fire Safety Manual Inspection Forms - Automatic Sprinkler Systems | PDF"]