[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-253832-105":53,"doc-detail-253832-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","factory-start-up-checklist-version-200-hvac-contractor","Factory Start-up Checklist - Version 2.00 - HVAC Contractor","","Factory Start-up Checklist用于HVAC承包商在设备现场完成开机前的各项核验与测试记录。表格覆盖客户与项目信息、安装与接线检查、过滤与冷凝排水确认、供回风与送风风机、压缩机及冷凝风机运行测试、热气再热与加热（如适用）功能验证，并要求核对制冷剂充注、气流参数及温控设定。同时包含BACnet点位截图、VFD设置与电气读数、制冷回路与压力/温度/过热度数据表，便于在指定启动日期前完成签署并回传。",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":36,"@type":70,"position":76},"https://docshare.wps.com/template/forms/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/factory-start-up-checklist-version-200-hvac-contractor/253832/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/factory-start-up-checklist-version-200-hvac-contractor/253832.png","ImageObject",442,249,{"name":88,"@type":89},"\tWilliam","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-23","2026-09-13",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",7,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"开机前需要完成哪些关键系统测试？","Question",{"text":109,"@type":110},"需完成设备外观检查、分体系统接管与接线核对、必要间隙确认、端子螺丝与现场布线紧固检查、过滤器安装、冷凝排水确认，以及电压检查与送风/压缩机/冷凝风机/热气再热/加热等运行测试。","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"表格要求的回传与启动日期有什么要求？",{"text":114,"@type":110},"启动日期需要尽快与办公室安排，且需预留三周计划时间。所有页面的条目必须在启动日前完成、签署，并通过传真或邮件回传办公室。",{"name":116,"@type":107,"acceptedAnswer":117},"需要记录哪些VFD与电气读数？",{"text":118,"@type":110},"表格包含Cooling/Heating VFD setting与Compressor VFD Parameters（如Circuit 1/2的参数），以及Supply Voltage、风机与压缩机/冷凝风机电流等Electrical Data读数，并在相关步骤中填入对应单位与数值。","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},253832,1790192318,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":35,"category_name":36,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":101,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":76},5909887254083,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Factory Start-up Checklist  \nHVAC Contractor:   Date:   Requested Start-up Date:   Project:   Qualiﬁed Technician   Model \\#:   Serial \\# :    \nProject Address:    \n______________________________________________________________  \nCustomer Name:   Customer Contact:   Phone:   Fax:   Email:   Customer Address:    \n_____________________________________________________________  \nNote: The above start-up date needs to be scheduled with our office immediately. Allow three weeks lead time to schedule start. The items on all pages must be completed, signedoff and faxed or emailed to our office prior to the start-up date. Please fill out completely.  \nProper equipment start-up is critical to customer comfort and equipment longevity. Utilize the following form to ensure that all the Pre-start-up procedures have been completed. The technician should initial each step as it has been completed and fill out the required start-up values. This form will provide the technician confidence that the system was thoroughly evaluated and installed properly. A separate checklist must be prepared and signed for all units to be started on the same date. Additional P.O. amount may be necessary for separate startup dates. Please contact your Sales Engineer.  \nNote: The installing contractor’s start-up technician must be present when iAIRE's start-up technician arrives on site for proper coordination and instructions on unit operation. The installing contractor is responsible for properly operating the unit after iAIRE's start-up technician leaves the job site.  \nStartup services require the installer to complete the manufacturers’ pre-startup checklist on the next page prior to requesting startup.  \nAfter completing this checklist, please scan and email back to iAIRE  \n[at Support@myiaire.com](at Support@myiaire.com)  \nFRM-TS-0004  \nPD 01/08/2026-v 2.00  \niAIRE, Inc. | 1240 S. Hoagland Blvd., Kissimmee, FL 34741 [www.myiaire.com | Toll](www.myiaire.com | Toll) Free 844-348-9168  \nFactory Startup Checklist  \n| Item System Testing Completed |  |  |\n| --- | --- | --- |\n|  | Inspect unit for damage. |  |\n|  | Ensure split systems are completely plumbed and wired. |  |\n|  | Is unit installed with proper clearances? |  |\n|  | Check terminal screws & wiring for connection & tightness. |  |\n|  | Ensure filters are installed. |  |\n|  | If unit is a space temperature device, ensure that wire run is twisted & shielded. |  |\n|  | Ensure condensate drain is trapped properly and not damaged. |  |\n|  | Check to ensure all field wiring is complete. |  |\n|  | Ensure correct voltage is run to the unit. |  |\n|  | Check supply air fan belt tension is correct. |  |\n|  | Check blower pulley & wheel are tight on shaft. |  |\n|  | “Bump” power to ensure correct blower rotation. |  |\n|  | Make sure outside air damper opens before any testing is started. |  |\n|  | Test operation of supply fan. |  |\n|  | Test operation of all compressors. |  |\n|  | Test operation of condenser fan. |  |\n|  | Test operation of hot gas reheat. |  |\n|  | Test operation of heating (if applicable) . |  |\n|  | Verify proper refrigerant charge. |  |\n|  | Verify proper airflow. |  |\n|  | Confirm that the unit Space or DAT temperature control is correct. |  |\n|  | Screenshot of BACNet Points. |  |\n|  | Confirm that all shipping brackets in condenser have been removed. |  |\n|  | Make unit cycle compressor on and off with controls to confirm operation |  |\n\nPictures of: Change Out Damage Rework Major Components  \nRecord program version:   Extension board version:    \n\n| Cooling VFD setting |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n|  Heating VFD setting  |  |  |  |  |  |  |\n|  | Entering Air Dry |  | Entering Air RH% |  | DX Coil (DAT Only) | Reheat Coil DAT Air Temp |\n| Cooling Stage 1 | °F |  | °F |  | °F | °F |\n\nCompressor VFD Parameters  \n\n| Circuit 1 | P100 | P101 | P102 | P103 | P104 | P110 | P140 | P160 | P161 |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  | ","cbCaiteIqhqKXXM6","https://ap.wps.com/l/cbCaiteIqhqKXXM6","pdf",795708,"English","# Factory Start-up Checklist\n## Project and Customer Information\n## Pre-start-up and System Testing\n## VFD Settings and Parameters\n## Electrical Data\n## Refrigerant, Cooling, and Heating Readings","[{\"question\":\"开机前需要完成哪些关键系统测试？\",\"answer\":\"需完成设备外观检查、分体系统接管与接线核对、必要间隙确认、端子螺丝与现场布线紧固检查、过滤器安装、冷凝排水确认，以及电压检查与送风/压缩机/冷凝风机/热气再热/加热等运行测试。\"},{\"question\":\"表格要求的回传与启动日期有什么要求？\",\"answer\":\"启动日期需要尽快与办公室安排，且需预留三周计划时间。所有页面的条目必须在启动日前完成、签署，并通过传真或邮件回传办公室。\"},{\"question\":\"需要记录哪些VFD与电气读数？\",\"answer\":\"表格包含Cooling/Heating VFD setting与Compressor VFD Parameters（如Circuit 1/2的参数），以及Supply Voltage、风机与压缩机/冷凝风机电流等Electrical Data读数，并在相关步骤中填入对应单位与数值。\"}]","Factory Start-up Checklist - Version 2.00 - HVAC Contractor | PDF",1789270807]