[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-194699-105":3,"detail-sidebar-cat-1-en-105":81,"doc-detail-194699-en":127},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","electrical-site-plan","Electrical Site Plan","","This document details various electrical site plans, including electrical site plans, lightning protection and counterpoise composite plans, and grounding plans. It also includes one-line diagrams for power and grounding, as well as power and lighting plans on a ¼ inch = 1.0 feet scale. Special systems plans are included as required. The document further specifies grounding details, low-voltage switchgear details, and motor control center (MCC) details, all of which show elevation and one-line information. Miscellaneous elementary and wiring diagrams, as well as miscellaneous details for lightning protection, are also provided. An equipment list is included, alongside a power duct plan and profile with a horizontal scale of 1 inch = 50 feet. Finally, details for high-voltage switchgear, transformers, and metering pads are presented, along with a primary (high-voltage) electrical system one-line diagram at a scale of 3/4 inch = 1 foot. A revision history indicates a substation revision on 12/13/11, which included formatting, branding, and editing, with updated requirements for motor disconnects, outdoor enclosures, protection of dry transformers, and pilot lights on starters.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/general/","General",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/electrical-site-plan/194699/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/electrical-site-plan/194699.png","ImageObject",442,249,{"name":42,"@type":43},"Nguyễn Văn Học","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-09-26","2026-09-03",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the scale for the Electrical Site Plan?","Question",{"text":63,"@type":64},"The scale for the Electrical Site Plan is 1 inch = 20 feet.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What details are included for Low-Voltage Switchgear and Motor Control Center (MCC)?",{"text":68,"@type":64},"These details include elevation and one-line information.",{"name":70,"@type":61,"acceptedAnswer":71},"What revision was made on 12/13/11?",{"text":72,"@type":64},"Revision 0 on 12/13/11 involved formatting, branding, and editing, with updates to requirements for motor disconnects, outdoor enclosures, protection of dry transformers, and pilot lights on starters.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},194699,1788441778,{"code":4,"msg":82,"data":83},"success",[84,89,94,99,104,109,114,119,124],{"id":85,"doc_module":22,"doc_module_name":25,"category_name":86,"show_sort_weight":87,"slug":88},11,"Presentations",90,"presentations",{"id":90,"doc_module":22,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},12,"Resumes",80,"resumes",{"id":95,"doc_module":22,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},14,"Invoices",70,"invoices",{"id":100,"doc_module":22,"doc_module_name":25,"category_name":101,"show_sort_weight":102,"slug":103},15,"Posters",60,"posters",{"id":105,"doc_module":22,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},16,"Social Media",50,"social-media",{"id":110,"doc_module":22,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},17,"Forms",40,"forms",{"id":115,"doc_module":22,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},18,"Letters",30,"letters",{"id":120,"doc_module":22,"doc_module_name":25,"category_name":121,"show_sort_weight":122,"slug":123},21,"Paper Templates",5,"papers-templates",{"id":125,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":4,"slug":126},158,"general-158",{"code":4,"msg":82,"data":128},{"doc_id":79,"user_id":129,"nickname":42,"user_avatar":130,"doc_module":22,"category_id":125,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":136,"language":137,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":138,"faqs":139,"seo_title":140,"seo_description":12,"update_tm":80,"read_time":95},1374402739827,"https://ap-avatar.wpscdn.com/avatar/14000c97e7351f1a627?x-image-process=image/resize,m_fixed,w_180,h_180&k=1787885694763230660","| Rev | By | Date | Type | Change Description | ID |\n| --- | --- | --- | --- | --- | --- |\n| 0 | EB/JCG | 12/13/11 | Subst | Formatted, branded, and edited. Updated requirements for motor disconnects, outdoor enclosures, protection of dry transformers, and pilot lights on starters. |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n\n| Drawing | Scale | Remarks |\n| --- | --- | --- |\n| Electrical Site Plan | 1 inch = 20 feet |  |\n| Lightning Protection and Counterpoise Composite Plan | 1 inch = 20 feet |  |\n| Grounding Plan | 1 inch = 20 feet |  |\n| Power: One-Line Diagram | -- |  |\n| Grounding: One-Line Diagram | -- |  |\n| Power Plans | ¼ inch = 1.0 feet |  |\n| Lighting Plans | ¼ inch = 1.0 feet |  |\n| Special Systems Plans as required | ¼ inch = 1.0 feet |  |\n| Grounding Details | -- |  |\n| Low-Voltage Switchgear Details | -- | Show elevation and 1-line |\n| Motor Control Center (MCC) Details | -- | Show elevation and 1-line |\n| Miscellaneous Elementary and Wiring Diagrams | -- |  |\n| Miscellaneous Details: Lightning Protection | -- |  |\n| Equipment List | -- |  |\n| Power Duct Plan and Profile (Civil Work Drawing) | 1 inch = 50 feet\u003Cbr>horizontal |  |\n| High-Voltage Switchgear, Transformer, Metering Pad Details | -- |  |\n| Primary (High-Voltage) Electrical System One-Line Diagram | 3/4 inch = 1 foot |  |","cbCaif4799V09Vhk","https://ap.wps.com/l/cbCaif4799V09Vhk","pdf",194082,39,"English","# Revision History\n# Drawings and Scales\n## Electrical Site Plan\n## Lightning Protection and Counterpoise Composite Plan\n## Grounding Plan\n## Power: One-Line Diagram\n## Grounding: One-Line Diagram\n## Power Plans\n## Lighting Plans\n## Special Systems Plans as required\n## Grounding Details\n## Low-Voltage Switchgear Details\n## Motor Control Center (MCC) Details\n## Miscellaneous Elementary and Wiring Diagrams\n## Miscellaneous Details: Lightning Protection\n## Equipment List\n## Power Duct Plan and Profile (Civil Work Drawing)\n## High-Voltage Switchgear, Transformer, Metering Pad Details\n## Primary (High-Voltage) Electrical System One-Line Diagram","[{\"question\":\"What is the scale for the Electrical Site Plan?\",\"answer\":\"The scale for the Electrical Site Plan is 1 inch = 20 feet.\"},{\"question\":\"What details are included for Low-Voltage Switchgear and Motor Control Center (MCC)?\",\"answer\":\"These details include elevation and one-line information.\"},{\"question\":\"What revision was made on 12/13/11?\",\"answer\":\"Revision 0 on 12/13/11 involved formatting, branding, and editing, with updates to requirements for motor disconnects, outdoor enclosures, protection of dry transformers, and pilot lights on starters.\"}]","Electrical Site Plan | PDF"]