[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-354372-105":53,"doc-detail-354372-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","electrical-safety-program-osha-1910331-335-safety-related-work-practices","Electrical Safety Program - OSHA 1910.331-335 - Safety Related Work Practices","","City of Newport News Electrical Safety Program defines requirements to prevent electric shock and other injuries from direct or indirect electrical contacts for employees working on or near electrical equipment and circuit parts operating at or above 50 volts. The scope covers all affected City work operations, including training for employees exposed to electrical hazards. It references OSHA 1910.331-335 and includes key definitions, responsibilities, and application of covered work practices and exclusions.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":36,"@type":70,"position":76},"https://docshare.wps.com/template/forms/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/electrical-safety-program-osha-1910331-335-safety-related-work-practices/354372/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/electrical-safety-program-osha-1910331-335-safety-related-work-practices/354372.png","ImageObject",442,249,{"name":88,"@type":89},"Ophelia","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-21","2026-09-22",true,{"@type":98,"interactionType":99,"userInteractionCount":76},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What is the purpose of the City of Newport News Electrical Safety Program?","Question",{"text":108,"@type":109},"It establishes requirements to prevent electric shock and other injuries from direct or indirect electrical contacts for employees working on or near electrical equipment and circuit parts operating at or above 50 volts.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"What work situations fall under the program’s scope?",{"text":113,"@type":109},"The program applies to City work operations where employees may be exposed to energized electrical equipment or circuit parts operating at or above 50 volts, and it also requires training for employees who work around such equipment and could face electrical hazards.",{"name":115,"@type":106,"acceptedAnswer":116},"Which OSHA standards are referenced in the program?",{"text":117,"@type":109},"The program references OSHA General Industry CFR 1910.331-335 (Subpart S) and also cites CFR 1910.147 for Lockout/Tagout and CFR 1910.146 for the Confined Space Standard.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},354372,1791718103,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":35,"category_name":36,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":76,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":141},7971461741311,"https://ap-avatar.wpscdn.com/avatar/74000253aff267980c6?x-image-process=image/resize,m_fixed,w_180,h_180&k=1779345379180704826","CITY OF NEWPORT NEWS ELECTRICAL SAFETY PROGRAM  \nOSHA 1910.331-335 Safety Related Work Practices  \nElectrical Safety Program  \nI. PURPOSE  \nThis program establishes requirements for preventing electric shock or other injuries resulting from direct/indirect electrical contacts to employees working on or near electrical equipment and circuit parts operating at or above 50 volts.  \nII. SCOPE  \nThis program applies to all work operations in the City of Newport News where employees may be exposed to energized electrical equipment or circuit parts operating at or above 50 volts.  \nIn addition, employees working around, but not on, electrical equipment operating at 50 volts or higher and have the potential to be exposed to an electrical hazard must be trained in the inherent danger of electricity.  \nIII. REFERENCE  \nOccupational Safety & Health Administration (OSHA) for General Industry CFR 1910.331-335, Subpart S-Electrical Safety-Related Work Practices. CFR 1910.147, Control of Hazardous Energy Source (Lockout/Tagout) Standard and CFR 1910.146, Confined Space Standard.  \nIV. DEFINITION  \n􀁸 Affected Person – a person whose job requires him/her to operate or use a machine or equipment on which servicing or maintenance is being performed under lockout or tagout, or whose job requires him/her to work in an area in which such servicing or maintenance is being performed.  \n􀁸 Authorized Person – a person who locks out or tag out machines or equipment in order to perform servicing or maintenance on that machine or equipment. An affected employee becomes an authorized employee when that employee’s duties include performing servicing or maintenance.  \n􀁸 De-energized – all stored or residual energy source has been blocked or cutoff and tested for the absence of voltage by approved means.  \n􀁸 Energized – connected to an energy source or potentially containing residual or stored energy.  \n􀁸 Energy Isolating Device – a mechanical device that physically prevents the transmission or release of energy, including but not limited to the following: A manually operated electrical circuit breaker; a disconnect switch; a manually operated switch by which the conductors of a circuit can be disconnected from all ungrounded supply conductors, and in addition, no pole can be operated independently; a line valve; a block; and any similar device used to block or  \nisolate energy. Push buttons, selector switches and other control circuit type devices are not energy isolating devices.  \n􀁸 Energy Source – any source of electrical voltage/power.  \n􀁸 Lockout – the placement of a lockout device on an energy-isolating device, in accordance with an established procedure, ensuring that the energy isolating device and the equipment being controlled cannot be operated until the lockout device is removed.  \n􀁸 Lockout Device – a device that utilizes a positive means such as a lock, either key or combination type, to hold an energy isolating device in a safe position and prevent the energizing of a machine or equipment. Included are blank flanges and bolted slip blinds.  \n􀁸 Qualified Person – one familiar with the construction and operations of the equipment and the hazards involved.  \n􀁸 Tagout – the placement of a tagout device on an energy-isolating device, in accordance with an established procedure, to indicate that the energy isolating device and the equipment being controlled may not be operated until thetagout device is removed.  \n􀁸 Tagout Device – a prominent warning device, such as a tag and a means of attachment, which can be securely fastened to an energy isolating device in accordance with an established procedure, to indicate that the energy isolating device and the equipment being controlled may not be operated until thetagout device is removed.  \n􀁸 Unqualified Person – one not familiar with the construction and operations of the equipment and hazards involved.  \n􀁸 Voltage, nominal – a nominal value assigned to a circuit or system for the purpose of convenient","cbCaimwwt6dfTpNt","https://ap.wps.com/l/cbCaimwwt6dfTpNt","pdf",328476,19,"English","# Purpose\n# Scope\n# Reference\n# Definition\n# Responsibilities\n# Application\n## Work practices covered\n## Work performed by unqualified persons\n## Exclusions for qualified persons","[{\"question\":\"What is the purpose of the City of Newport News Electrical Safety Program?\",\"answer\":\"It establishes requirements to prevent electric shock and other injuries from direct or indirect electrical contacts for employees working on or near electrical equipment and circuit parts operating at or above 50 volts.\"},{\"question\":\"What work situations fall under the program’s scope?\",\"answer\":\"The program applies to City work operations where employees may be exposed to energized electrical equipment or circuit parts operating at or above 50 volts, and it also requires training for employees who work around such equipment and could face electrical hazards.\"},{\"question\":\"Which OSHA standards are referenced in the program?\",\"answer\":\"The program references OSHA General Industry CFR 1910.331-335 (Subpart S) and also cites CFR 1910.147 for Lockout/Tagout and CFR 1910.146 for the Confined Space Standard.\"}]","Electrical Safety Program - OSHA 1910.331-335 - Safety Related Work Practices | PDF",1790110353,7]