[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-162257-105":53,"doc-detail-162257-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","eba-one-operative-technique-single-lag-screw-nailing-system","Eba One-Operative technique - Single lag screw nailing system","","The Eba One-Operative technique describes a single lag screw nailing system for surgical treatment of proximal femoral fractures. It outlines the decision-making approach based on clinical judgement and patient needs, stresses that surgeons must consult the package insert, product label and instructions for use, and clarifies that product availability may vary by market. The content provides product description details and step-by-step procedural elements including patient positioning and entry point planning, guide wire insertion, intramedullary canal reaming, nail insertion, and locking strategies, as well as implant completion and removal.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":36,"@type":70,"position":76},"https://docshare.wps.com/template/forms/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/eba-one-operative-technique-single-lag-screw-nailing-system/162257/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/eba-one-operative-technique-single-lag-screw-nailing-system/162257.png","ImageObject",442,249,{"name":88,"@type":89},"Hazel","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-09-19","2026-08-30",true,{"@type":98,"interactionType":99,"userInteractionCount":73},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What does the Eba One single lag screw nailing system treat?","Question",{"text":108,"@type":109},"It is indicated for stable and unstable intertrochanteric fractures, pertrochanteric fractures, mal-unions, and non-unions, with additional indications for the long nail including pertrochanteric/subtrochanteric patterns extending to the diaphysis and pathological fractures.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"What guidance must surgeons follow before using the product?",{"text":113,"@type":109},"Surgeons must consult the package insert, product label, and/or instructions for use before operating, and should receive training in the use of the specific product prior to surgery.",{"name":115,"@type":106,"acceptedAnswer":116},"How is the patient positioned for the procedure?",{"text":117,"@type":109},"The patient is placed supine on a radiolucent operating table with the limb under skeletal traction; the contralateral hip and knee are flexed by 90°, and the treated limb is adducted by 20°–30° to support surgical access and imaging.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},162257,1788121242,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":35,"category_name":36,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":73,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":125,"read_time":25},137441390410,"https://ap-avatar.wpscdn.com/avatar/2000252f4ab5702993?_k=1776741390130283984","Operative technique  \nSingle lag screw nailing system  \nEba One-Operative technique    \nSurgeons must always decide on the best approach to follow according to their clinical judgement and the patient’s needs. Citieffe does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the extent of Citieffe product offerings.  \nBefore use a surgeon must always consult the package insert, product label and/or instructions for use. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets.  \nPlease contact your Citieffe representative if you have questions about the availability of Citeffe products in your area.  \n 2  \n CONTENTS  \nPRODUCT DESCRIPTION  4  \nINDICATIONS  8  \nPATIENT POSITIONING AND ENTRY POINT  9  \nGUIDE WIRE INSERTION  10  \nINTRAMEDULLARY CANAL REAMING  11  \nNAIL INSERTION  12  \nPROXIMAL LOCKING  13  \nEBA ONE STANDARD (SHORT) DISTAL LOCKING  19  \nDISTAL LOCKING WITH EBA ONE LONG CENTERING GUIDE  21  \nEBA ONE LONG DISTAL LOCKING WITH FREE-HAND TECHNIQUE  27  \nTARGETING DEVICE REMOVAL  29  \nIMPLANT COMPLETION  30  \nIMPLANT REMOVAL  31  \nORDERING INFORMATION  34  \n3   \nEba One-Operative technique    \nPRODUCT DESCRIPTION TITANIUM STERILE   \nSingle lag screw nailing system for the treatment of proximal femural fractures, available in the standard and long version.  \nEba One standard nail  \nEnd cap recess  \nIntegrated cephalic screw antirotation system  \nHole for stabilization guide wire, ø3mm  \nCephalic screw hole  \nProximal flattening  \n• Titanium ASTM F136 alloy  \n• Cervical-diaphyseal angle 120° -125° -130°  \n• Metaphyseal angle 5°  \n• Proximal diameter 15.5mm  \n• Distal diameter 10, 11mm  \n• Length 170mm  \nDynamic or static  locking slot  \n 4  \n   Eba One-Operative technique  \nEba One long nail  \nEnd cap recess  \nIntegrated cephalic screw antirotation system  \nHole for stabilization guide wire, ø3mm  \nCephalic screw hole  \nProximal flattening  \n• Titanium ASTM F136 alloy  \n• Cervical-diaphyseal angle 130°  \n• Metaphyseal angle 5°  \n• Proximal diameter 15.5mm  \n• Distal diameter  \n-solid nail: 9mm  \n-cannulated nail: 10, 11, 12, 13mm  \n• Length  \n- solid nail: from 280mm to 380mm with 20mm increments  \n- cannulated nail: from 280mm to 460mm with 20mm increments  \n• Radius of curvature 1.0 m, RIGHT-LEFT  \n• Proximal anterversion of 10°  \nStatic locking hole  \nDynamic or static locking slot  \n5   \nEba One-Operative technique    \nIntegrated cephalic screw antirotation system  \nEba One features an integrated cephalic screw antirotation system that prevents the rotation and the medial migration of the cephalic screw.  \nThe locking screw is cannulated and integrated into the nail; a single  \nmovement prevents the cephalic screw from turning, whilst allowing it to slide. Eba One nails are supplied with the Integrated Locking screw in the OPEN position.  \nHole for stabilization guide wire, ø3mm  \nThe Eba One nail features a hole for the insertion of the stabilization guide wire, ø3mm through the Eba One targeting device.  \nThe guide wire is positioned parallel to the cephalic screw in order to enable fracture compaction without requiring the removal of the wire.  \nstabilization guide wire,ø3mm parallel to the cephalic screw  \n6  \nProximal flattening  \nThe proximal flattening favours easy insertion of the Eba One nail.  \nScrews and end caps  \nThe screws and caps of the Eba One system are characterized by a retention system that keeps them integral with the screwdriver during insertion.  \nThe cortical screw and end cap Eba One have a head with a 5mm hexagonal insert that allows the use of a single T-screwdriver.  \nCephalic screw ø10.5mm  \nCortical screw ø5.2mm  \nEnd cap  \n• Titanium alloy  \n• Self-tapping  \n• Blunt tip  \n• Available lengths: from 22. 5mm to 110mm with 2. 5mm increments (up to 55mm) and 5mm increme","cbCaia17UYbPU1tq","https://ap.wps.com/l/cbCaia17UYbPU1tq","pdf",3161065,44,"English","# PRODUCT DESCRIPTION\n## INDICATIONS\n## PATIENT POSITIONING AND ENTRY POINT\n## GUIDE WIRE INSERTION\n## INTRAMEDULLARY CANAL REAMING\n## NAIL INSERTION\n## PROXIMAL LOCKING\n## EBA ONE STANDARD (SHORT) DISTAL LOCKING\n## DISTAL LOCKING WITH EBA ONE LONG CENTERING GUIDE\n## EBA ONE LONG DISTAL LOCKING WITH FREE-HAND TECHNIQUE\n## TARGETING DEVICE REMOVAL\n## IMPLANT COMPLETION\n## IMPLANT REMOVAL\n## ORDERING INFORMATION","[{\"question\":\"What does the Eba One single lag screw nailing system treat?\",\"answer\":\"It is indicated for stable and unstable intertrochanteric fractures, pertrochanteric fractures, mal-unions, and non-unions, with additional indications for the long nail including pertrochanteric/subtrochanteric patterns extending to the diaphysis and pathological fractures.\"},{\"question\":\"What guidance must surgeons follow before using the product?\",\"answer\":\"Surgeons must consult the package insert, product label, and/or instructions for use before operating, and should receive training in the use of the specific product prior to surgery.\"},{\"question\":\"How is the patient positioned for the procedure?\",\"answer\":\"The patient is placed supine on a radiolucent operating table with the limb under skeletal traction; the contralateral hip and knee are flexed by 90°, and the treated limb is adducted by 20°–30° to support surgical access and imaging.\"}]","Eba One-Operative technique - Single lag screw nailing system | PDF"]