[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-393306-105":3,"doc-detail-393306-en":81,"detail-sidebar-cat-1-en-105":98},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","drawings-31-38","Drawings-31-38","","Document content captures construction drawing metadata and technical reference information. It includes plot date and raw status, project location path details, and a fire protection requirements section addressing firestopping for penetrations, constraints for electrical openings, spacing for outlet boxes, and code-driven behavior for lighting and apparatus in fire-rated ceiling assemblies. The file also provides an electrical abbreviations list mapping common shorthand to full terms and system components used in electrical and building services design.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/paper-templates/","Paper Templates",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/drawings-31-38/393306/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/drawings-31-38/393306.png","ImageObject",442,249,{"name":42,"@type":43},"Nguyễn Văn Học","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-12","2026-09-26",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What does the document require for penetrations in walls requiring protected openings?","Question",{"text":63,"@type":64},"Penetrations must be firestopped with an approved material. Conduits may penetrate provided they are fire-stopped.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What limits apply to openings for steel electrical boxes in walls or partitions?",{"text":68,"@type":64},"Openings for steel electrical boxes not exceeding 16 square inches are permitted, provided openings do not aggregate more than 100 square inches for any 100 square feet of wall or partition.",{"name":70,"@type":61,"acceptedAnswer":71},"What requirements apply to recessed lighting fixtures installed in fire-rated ceiling assemblies?",{"text":72,"@type":64},"Recessed lighting fixtures must be fire-rated fixtures bearing the UL fire-rated label and installed per the UL fire resistance directory, including a fire-rated enclosure meeting the directory requirements.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},393306,1791031190,{"code":4,"msg":82,"data":83},"success",{"doc_id":79,"user_id":84,"nickname":42,"user_avatar":85,"doc_module":22,"category_id":86,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":87,"file_id":88,"file_url":89,"file_type":90,"file_size":91,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":92,"language":93,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":94,"faqs":95,"seo_title":96,"seo_description":12,"update_tm":97,"read_time":30},1374402739827,"https://ap-avatar.wpscdn.com/avatar/14000c97e7351f1a627?x-image-process=image/resize,m_fixed,w_180,h_180&k=1787885694763230660",21,"PLOT DATE: 6/ 1 7/ 20 1 6 2: 2 0: 07 PM  \nRAW STATUING NA PLOT DW G NAME: D LW 03 1 E 1 . DWG  \nPROJECT LOCATION: C:\\ Rev i t Local F iles\\ 1 50523 US FW-De Lakes Main tetro i t nance Bu i lding E16 _ ms b i l be . rvt  \n\n| SPECIFIC CODE NOTES |  |\n| --- | --- |\n| FIRE PROTECTION REQUIREMENTS\u003Cbr>A. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS MUST BE FIRESTOPPED WITH AN APPROVED MATERIAL.\u003Cbr>1. CONDUITS MAY PENETRATE WALLS OR\u003Cbr>PARTITIONS, PROVIDED THEY ARE FIRE-STOPPED.\u003Cbr>2. OPENINGS FOR STEEL ELECTRICAL BOXES NOT EXCEEDING 16 SQUARE INCHES ARE PERMITTED PROVIDED OPENINGS DO NOT AGGREGATE MORE THAN 100 SQUARE INCHES FOR ANY 100 SQUARE FEET OF WALL OR PARTITION.\u003Cbr>3. OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR PARTITIONS MUST BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.\u003Cbr>B. LIGHT FIXTURES AND OTHER APPARATUS SUPPORTED BY THE ACOUSTICAL CEILING GRID MUST MEET THE REQUIREMENTS OF NEC SECTION\u003Cbr>410. 16, MEANS OF SUPPORT.\u003Cbr>C. RECESSED LIGHTING FIXTURES INSTALLED IN FIRE RATED CEILING ASSEMBLIES SHALL BE FIRE RATED FIXTURES BEARING THE UL FIRE RATED LABEL. FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE UL FIRE RESISTANCE DIRECTORY, AND SHALL INCLUDE A FIRE RATED ENCLOSURE INSTALLED OVER THE FIXTURE THAT MEETS THE REQUIREMENTS OF THE UL FIRE RESISTANCE DIRECTORY. |  |\n\n| ELECTRICAL ABBREVIATIONS LIST |\n| --- |\n| 1P 1 POLE (2P, 3P, 4P, ETC. )\u003Cbr>A AMPERE\u003Cbr>AC ABOVE COUNTER OR AIR\u003Cbr>CONDITIONER\u003Cbr>ACLG ABOVE CEILING\u003Cbr>ADO AUTOMATIC DOOR OPENER\u003Cbr>AFF ABOVE FINISHED FLOOR\u003Cbr>AFG ABOVE FINISHED GRADE\u003Cbr>AFI ARC FAULT CIRCUIT INTERRUPTER\u003Cbr>AHU AIR HANDLING UNIT\u003Cbr>AL ALUMINUM\u003Cbr>AMP AMPERE\u003Cbr>AMPL AMPLIFIER\u003Cbr>ANNUN ANNUNCIATOR\u003Cbr>APPROX APPROXIMATELY AQ-STAT AQUASTAT\u003Cbr>ARCH ARCHITECT,ARCHITECTURAL\u003Cbr>ATS AUTOMATIC TRANSFER SWITCH\u003Cbr>AUTO AUTOMATIC\u003Cbr>AUX AUXILIARY\u003Cbr>AV AUDIO VISUAL\u003Cbr>AWG AMERICAN WIRE GAUGE\u003Cbr>BATT BATTERY\u003Cbr>BD BOARD\u003Cbr>BLDG BUILDING\u003Cbr>BMS BUILDING MANAGEMENT\u003Cbr>SYSTEM\u003Cbr>C CONDUIT\u003Cbr>CAB CABINET\u003Cbr>CATV CABLE TELEVISION\u003Cbr>CB CIRCUIT BREAKER\u003Cbr>CCTV CLOSED CIRCUIT TELEVISION\u003Cbr>CKT CIRCUIT\u003Cbr>CLG CEILING\u003Cbr>COMB COMBINATION\u003Cbr>CMPR COMPRESSOR\u003Cbr>CONN CONNECTION\u003Cbr>CONST CONSTRUCTION\u003Cbr>CONT CONTINUATION OR\u003Cbr>CONTINUOUS CONTR CONTRACTOR\u003Cbr>CONV CONVECTOR\u003Cbr>CP CIRCULATING PUMP\u003Cbr>CRT CATHODE-RAY TUBE\u003Cbr>CT CURRENT TRANSFORMER\u003Cbr>CTR CENTER\u003Cbr>CU COPPER\u003Cbr>DCP DOMESTIC WATER CIRCULATING\u003Cbr>PUMP DEPT DEPARTMENT\u003Cbr>DET DETAIL\u003Cbr>DIA DIAMETER\u003Cbr>DISC DISCONNECT DIST DISTRIBUTION\u003Cbr>DN DOWN\u003Cbr>DPR DAMPER\u003Cbr>DS SAFETY DISCONNECT SWITCH\u003Cbr>DT DOUBLE THROW\u003Cbr>DWG DRAWING\u003Cbr>EC ELECTRICAL CONTRACTOR\u003Cbr>ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR\u003Cbr>EM EMERGENCY\u003Cbr>EMS ENERGY MANAGEMENT SYSTEM\u003Cbr>EMT ELECTRICAL METALLIC TUBING\u003Cbr>EP ELECTRIC PNEUMATIC\u003Cbr>EQUIP EQUIPMENT\u003Cbr>EWC ELECTRIC WATER COOLER EXIST EXISTING\u003Cbr>EXH EXHAUST\u003Cbr>EXP EXPLOSION PROOF\u003Cbr>FA FIRE ALARM\u003Cbr>FACP FIRE ALARM CONTROL PANEL FCU FAN COIL UNIT\u003Cbr>FIXT FIXTURE\u003Cbr>FLR FLOOR\u003Cbr>FLUOR FLUORESCENT FU FUSE\u003Cbr>FUDS FUSED SAFETY DISCONNECT SWITCH\u003Cbr>GA GAUGE\u003Cbr>GAL GALLON\u003Cbr>GALV GALVANIZED\u003Cbr>GC GENERAL CONTRACTOR\u003Cbr>GEN GENERATOR\u003Cbr>GFI GROUND FAULT CIRCUIT\u003Cbr>INTERRUPTER\u003Cbr>GFP GROUND FAULT PROTECTOR\u003Cbr>GND GROUND\u003Cbr>GRS GALVANIZED RIGID STEEL\u003Cbr>(CONDUIT) GYP BD GYPSUM BOARD\u003Cbr>HOA HANDS-OFF-AUTOMATIC SWITCH HORIZ HORIZONTAL\u003Cbr>HP HORSEPOWER\u003Cbr>HPF HIGH POWER FACTOR\u003Cbr>HT HEIGHT\u003Cbr>HTG HEATING\u003Cbr>HTR HEATER\u003Cbr>HV HIGH VOLTAGE\u003Cbr>HWP HYDRONIC WATER PUMP\u003Cbr>IC INTERRUPTING CAPACITY\u003Cbr>IDSCP INTRUSION DETECTION SYSTEM CONTROL PANEL\u003Cbr>IG ISOLATED GROUND\u003Cbr>IMC INTERMEDIATE METAL CONDUIT\u003Cbr>INCAND INCANDESCENT IR INFRARED\u003Cbr>I/W INTERLOCK WITH\u003Cbr>J-BOX JUNCTION BOX\u003Cbr>KV KILOVOLT\u003Cbr>KVA KILOVOLT-AMPERE\u003Cbr>KVAR KILOVOLT-AMPERE REACTIVE KW KILOWATT\u003Cbr>KWH KILOWATT HOUR\u003Cbr>LOC LOCATE OR LOCATION\u003Cbr>LT LIGHT\u003Cbr>LTG LIGHTING\u003Cbr>LTNG LIGHTNING\u003Cbr>LV LOW VOLTAGE\u003Cbr>MAX MAXIMUM\u003Cbr>MAG.S MAGNETIC STARTERM/C MOMENTARY CONTACT\u003Cbr>MC MECHANICAL CONTRACTOR\u003Cbr>MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDC MAIN DISTRIBUTION CENTER MDP MAIN D","cbCaibJlrBvLZmbk","https://ap.wps.com/l/cbCaibJlrBvLZmbk","pdf",737051,8,"English","# Specific Code Notes\n## Fire Protection Requirements\n## Electrical Abbreviations List","[{\"question\":\"What does the document require for penetrations in walls requiring protected openings?\",\"answer\":\"Penetrations must be firestopped with an approved material. Conduits may penetrate provided they are fire-stopped.\"},{\"question\":\"What limits apply to openings for steel electrical boxes in walls or partitions?\",\"answer\":\"Openings for steel electrical boxes not exceeding 16 square inches are permitted, provided openings do not aggregate more than 100 square inches for any 100 square feet of wall or partition.\"},{\"question\":\"What requirements apply to recessed lighting fixtures installed in fire-rated ceiling assemblies?\",\"answer\":\"Recessed lighting fixtures must be fire-rated fixtures bearing the UL fire-rated label and installed per the UL fire resistance directory, including a fire-rated enclosure meeting the directory requirements.\"}]","Drawings-31-38 | PDF",1790382895,{"code":4,"msg":82,"data":99},[100,105,110,115,120,125,130,135,138],{"id":101,"doc_module":22,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},11,"Presentations",90,"presentations",{"id":106,"doc_module":22,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},12,"Resumes",80,"resumes",{"id":111,"doc_module":22,"doc_module_name":25,"category_name":112,"show_sort_weight":113,"slug":114},14,"Invoices",70,"invoices",{"id":116,"doc_module":22,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},15,"Posters",60,"posters",{"id":121,"doc_module":22,"doc_module_name":25,"category_name":122,"show_sort_weight":123,"slug":124},16,"Social Media",50,"social-media",{"id":126,"doc_module":22,"doc_module_name":25,"category_name":127,"show_sort_weight":128,"slug":129},17,"Forms",40,"forms",{"id":131,"doc_module":22,"doc_module_name":25,"category_name":132,"show_sort_weight":133,"slug":134},18,"Letters",30,"letters",{"id":86,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":136,"slug":137},5,"papers-templates",{"id":139,"doc_module":22,"doc_module_name":25,"category_name":140,"show_sort_weight":4,"slug":141},158,"General","general-158"]