[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-198110-105":53,"doc-detail-198110-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","door-hardware-installation-manual","Door Hardware Installation Manual","","This document provides detailed instructions for the installation of door hardware, specifically focusing on sliding door systems. It includes comprehensive tables outlining the required dimensions for rough openings, correlating nominal door sizes with the precise width and height specifications needed for proper installation. Table 1 specifies the minimum rough opening height, bracket fastener height from the finished floor, and bracket fastener height from the sub-floor for different nominal door heights (80” and 84”). Table 2 details the width of the rough opening required for various nominal door widths (30”, 32”, and 36”). Accompanying diagrams visually guide the user through the process, illustrating how specific hardware components, such as brackets (labeled 'F' and 'C' in the diagrams, with quantities indicated as 'x1'), are attached to the door frame and track system. The instructions highlight the precise measurements, such as 8-11/64\" (233mm), demonstrating the accuracy required for a smooth and functional sliding mechanism. The visual aids emphasize the correct placement and movement of the door panels and their corresponding hardware, ensuring a secure and efficient setup.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/door-hardware-installation-manual/198110/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/door-hardware-installation-manual/198110.png","ImageObject",442,249,{"name":88,"@type":89},"Putri","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-09-26","2026-09-03",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",8,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What are the minimum rough opening dimensions for an 80-inch nominal door height?","Question",{"text":109,"@type":110},"For an 80-inch nominal door height, the minimum rough opening height is 84-1/2 inches. The bracket fastener height should be 80-3/4 inches from the finished floor and 81-1/2 inches from the sub-floor.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"What is the required rough opening width for a 32-inch nominal door width?",{"text":114,"@type":110},"A 32-inch nominal door width requires a rough opening width of 65 inches.",{"name":116,"@type":107,"acceptedAnswer":117},"What do the diagrams illustrate regarding the installation process?",{"text":118,"@type":110},"The diagrams visually guide the user through attaching hardware components like brackets to the door frame and track system, emphasizing precise measurements for a functional sliding mechanism.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},198110,1788474675,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":136,"language":137,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":138,"faqs":139,"seo_title":140,"seo_description":61,"update_tm":126,"read_time":141},962085571259,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","| Height of Rough Opening (Table 1) |  |  |  |\n| --- | --- | --- | --- |\n| Nominal\u003Cbr>Door Height | Minimum Height of Rough Opening | Bracket Fastener Height\u003Cbr>from finished floor | Bracket Fastener Height\u003Cbr>from sub-floor |\n| 80” | 84-1/2” | 80-3/4” | 81-1/2” |\n| 84” | 88-1/2” | 84-3/4” | 85-1/2” |\n\n\n| Width of Rough Opening (Table 2) |  |\n| --- | --- |\n| Nominal Door Width | Width of Rough Opening |\n| 30” | 61” |\n| 32” | 65” |\n| 36” | 73” |","cbCaihfWR8M6aOOE","https://ap.wps.com/l/cbCaihfWR8M6aOOE","pdf",3466492,96,"English","# Door Hardware Installation\n## Height of Rough Opening (Table 1)\n## Width of Rough Opening (Table 2)","[{\"question\":\"What are the minimum rough opening dimensions for an 80-inch nominal door height?\",\"answer\":\"For an 80-inch nominal door height, the minimum rough opening height is 84-1/2 inches. The bracket fastener height should be 80-3/4 inches from the finished floor and 81-1/2 inches from the sub-floor.\"},{\"question\":\"What is the required rough opening width for a 32-inch nominal door width?\",\"answer\":\"A 32-inch nominal door width requires a rough opening width of 65 inches.\"},{\"question\":\"What do the diagrams illustrate regarding the installation process?\",\"answer\":\"The diagrams visually guide the user through attaching hardware components like brackets to the door frame and track system, emphasizing precise measurements for a functional sliding mechanism.\"}]","Door Hardware Installation Manual | PDF",34]