[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-194700-105":53,"doc-detail-194700-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","division-26-pad-mount-transformers","Division 26 - Pad-Mount Transformers","","This document provides detailed specifications for liquid-filled, pad-mount transformers under Division 26. It presents two tables outlining various transformer models based on their kVA ratings, with corresponding Full Load Amps (FLA), 125% FLA, Overcurrent (O.C.) Device ratings, and preferred and alternate CT Turns Ratios. The first table details transformers operating at 12.47Y/7.2kV to 480Y/277V, featuring kVA ratings from 150 up to 3000. The second table covers transformers at 12.47Y/7.2kV to 208Y/120V, with kVA ratings ranging from 150 to 1000. This information is crucial for electrical engineers, system designers, and procurement specialists involved in power distribution projects requiring specific transformer configurations and protection features. The data allows for precise selection of transformers based on load requirements and protective device coordination.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/division-26-pad-mount-transformers/194700/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/division-26-pad-mount-transformers/194700.png","ImageObject",442,249,{"name":88,"@type":89},"Chumphorn","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-04","2026-09-03",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",6,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What are the different voltage levels for the pad-mount transformers listed?","Question",{"text":109,"@type":110},"The document specifies transformers for two voltage levels: 12.47Y/7.2kV to 480Y/277V and 12.47Y/7.2kV to 208Y/120V.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"What information is provided for each transformer model?",{"text":114,"@type":110},"For each transformer model, the document lists its kVA rating, Full Load Amps (FLA), 125% FLA, the recommended Overcurrent (O.C.) device rating, and preferred and alternate CT Turns Ratios.",{"name":116,"@type":107,"acceptedAnswer":117},"What is the maximum kVA rating specified for the 12.47Y/7.2kV-480Y/277V transformers?",{"text":118,"@type":110},"The maximum kVA rating for the 12.47Y/7.2kV-480Y/277V transformers listed is 3000 kVA.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},194700,1788441792,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":136,"language":137,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":138,"faqs":139,"seo_title":140,"seo_description":61,"update_tm":126,"read_time":42},2336475401981,"https://ap-avatar.wpscdn.com/avatar/22000c94efd8d5204d?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786935347598174694","|  | 12.47Y/7.2kV-480Y/277V LIQUID-FILLED, PAD-MOUNT TRANSFORMERS |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| kVA | FLA | 125% FLA | O.C. DEVICE | PREFERRED CT TURNS RATIO | ALTERNATE CT TURNS RATIO |  |\n| 150 | 180.4 | 225.5 | 225A/200A | 250 TO 5 | 200 TO 5 |  |\n| 225 | 270.6 | 338.3 | 350A/300A | 400 TO 5 | 300 TO 5 |  |\n| 300 | 360.8 | 451.1 | 450A/400A | 500 TO 5 | 400 TO 5 |  |\n| 500 | 601.4 | 751.8 | 800A/600A | 800 TO 5 | 600 TO 5 |  |\n| 750 | 902.1 | 1,127.6 | 1200A/1000A | 1200 TO 5 | 1000 TO 5 |  |\n| 1000 | 1,202.8 | 1,503.5 | 1600A | 1600 TO 5 | NONE |  |\n| 1500 | 1,804.2 | 2,255.3 | 2500A/2000A | 2500 TO 5 | 2000 TO 5 |  |\n| 2000 | 2,405.6 | 3,007.0 | 3000A | 3000 TO 5 | NONE |  |\n| 2500 | 3,007.0 | 3,758.8 | 4000A | 4000 TO 5 | NONE |  |\n| 3000 | 3,608.4 | 4,510.5 | 4000A | 4000 TO 5 | NONE |  |\n\n\n| 12.47Y/7.2kV-208Y/120V LIQUID-FILLED, PAD-MOUNT TRANSFORMERS |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| kVA | FLA | 125% FLA | Sec. O.C. Device | PREFERRED CT TURNS RATIO | ALTERNATE CT TURNS RATIO |\n| 150 | 416.4 | 520.4 | 600A/500A | 600 TO 5 | 500 TO 5 |\n| 225 | 624.5 | 780.7 | 800A | 800 TO 5 | NONE |\n| 300 | 832.7 | 1,040.9 | 1000A/1200A | 1000 TO 5 | 1200 TO 5 |\n| 500 | 1,387.9 | 1,734.8 | 2000A/1600A | 2000 TO 5 | 1600 TO 5 |\n| 750 | 2,081.8 | 2,602.2 | 3000A/2500A | 3000 TO 5 | 2500 TO 5 |\n| 1000 | 2,775.7 | 3,469.7 | 4000A/4000A | 4000 TO 5 | 3500 TO 5 |","cbCair9kGDqQaENr","https://ap.wps.com/l/cbCair9kGDqQaENr","pdf",9026975,85,"English","# 12.47Y/7.2kV-480Y/277V Liquid-Filled, Pad-Mount Transformers\n## kVA\n## FLA\n## 125% FLA\n## O.C. DEVICE\n## Preferred CT Turns Ratio\n## Alternate CT Turns Ratio\n# 12.47Y/7.2kV-208Y/120V Liquid-Filled, Pad-Mount Transformers\n## kVA\n## FLA\n## 125% FLA\n## Sec. O.C. Device\n## Preferred CT Turns Ratio\n## Alternate CT Turns Ratio","[{\"question\":\"What are the different voltage levels for the pad-mount transformers listed?\",\"answer\":\"The document specifies transformers for two voltage levels: 12.47Y/7.2kV to 480Y/277V and 12.47Y/7.2kV to 208Y/120V.\"},{\"question\":\"What information is provided for each transformer model?\",\"answer\":\"For each transformer model, the document lists its kVA rating, Full Load Amps (FLA), 125% FLA, the recommended Overcurrent (O.C.) device rating, and preferred and alternate CT Turns Ratios.\"},{\"question\":\"What is the maximum kVA rating specified for the 12.47Y/7.2kV-480Y/277V transformers?\",\"answer\":\"The maximum kVA rating for the 12.47Y/7.2kV-480Y/277V transformers listed is 3000 kVA.\"}]","Division 26 - Pad-Mount Transformers | PDF"]