[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-166632-105":53,"doc-detail-166632-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","division-01-general-requirements-section-017419-construction-waste-management","DIVISION 01 - GENERAL REQUIREMENTS - SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT","","Division 01 general requirements establish procedures and material scope for demolition and construction waste handling. Section 017419 requires salvaging and recycling all non-hazardous demolition and construction waste, listing concrete, wood, miscellaneous steel, doors and glazing, plumbing and electrical components, masonry and CMU, gypsum board, insulation, and uncontaminated packaging materials. Division 02 selective structure demolition sets requirements for utility disconnection, removal, lawful disposal of debris, temporary facilities, and detailed disassembly and protection of building elements during new work installation.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/division-01-general-requirements-section-017419-construction-waste-management/166632/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/division-01-general-requirements-section-017419-construction-waste-management/166632.png","ImageObject",442,249,{"name":88,"@type":89},"Anda","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/vnd.openxmlformats-officedocument.wordprocessingml.document","2026-09-29","2026-08-31",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",6,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What waste materials must be salvaged and recycled under Section 017419?","Question",{"text":109,"@type":110},"Non-hazardous demolition and construction waste must be salvaged and recycled, including concrete, wood joists/studs/trim, miscellaneous steel, doors and frames, windows and glazing, plumbing fixtures and piping components, and specified electrical and mechanical equipment. It also covers masonry/CMU, untreated wood materials, gypsum board, insulation, and uncontaminated packaging materials.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"What is required before selective structure demolition begins?",{"text":114,"@type":110},"All building utilities must be disconnected before any removal or demolition is commenced by the mechanical trades.",{"name":116,"@type":107,"acceptedAnswer":117},"What site protection and temporary requirements are included during demolition?",{"text":118,"@type":110},"A temporary sidewalk shed must be provided for the duration of construction contract work. Demolition work also requires protection of exposed wall areas until new sills are installed, plus temporary shoring before commencement of demolition.","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},166632,1788197084,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":130,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":27,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":126,"read_time":45},962075006959,"https://ap-avatar.wpscdn.com/avatar/e0002397efbe92a78e?_k=1776741047341049297","DIVISION 01 - GENERAL REQUIREMENTS\nSECTION 017419 - CONSTRUCTION WASTE MANAGEMENT\nSalvage and recycle all non-hazardous demolition and construction waste including the following materials:\nDemolition Waste:\nConcrete, concrete paving, and concrete cellar slab.\nWood joists, wood studs and wood trim.\nMiscellaneous steel.\nDoors and frames, rough hardware, door Hardware.\nWindows and glazing.\nPlumbing fixtures, piping, supports & hangers, and valves.\nMechanical equipment, electrical conduit, copper wiring, light fixtures, electrical devices, panelboards, and fuse-boxes.\nConstruction Waste:\nMasonry, CMU, piping and conduit.\nUntreated wood, wood sheet materials, and wood trim.\nGypsum board, insulation, and uncontaminated packaging materials.\nDIVISION 02 - EXISTING CONDITIONS\nSECTION 024119 – SELECTIVE STRUCTURE DEMOLITION\nAll building utilities shall be disconnected before any removal and or demolition is commenced by all mechanical trades.\nPerform all demolition required for installation of new work.\nRemove from the building site and dispose of in a legal manner all existing debris. See Master Guide Section 017419 – Construction Waste Management and Disposal.\nProvide temporary sidewalk shed for the duration of construction contract work. See Master Guide Section 015000 Temporary Facilities and Controls.\nRemove existing retaining walls where shown on Drawings.\nRemove all existing paving at yards, courts, air shafts, and fire passages.\nRemove existing sidewalk “flags” that have cracks, approximately \t   % of sidewalk. Remove entire curb.\nUnder direction of the Structural Engineer, remove existing masonry “apron” wall sections, which extend downward from windowsills to the top of the windows below where shown on Drawings.\nUnder direction of the Design Professional of Record, remove \t       % of windowsills at window openings, except at street façades where the windowsill is part of a continuous banding or decorative window surround. Provide protection for exposed wall areas until new sills are installed.\nRemove un-keyed stucco from exterior walls, approximately \t       square feet.\nMechanically remove tar from exterior walls, approximately \t       square feet.\nRemove existing gooseneck ladders at fire escapes between uppermost balcony and roof level.\nRemove existing fire escapes where shown on Drawings.\nRemove and scrape paint from existing fire escapes.\nRemove all existing kitchen cabinets including hangers, base cabinets, counter tops, grounds, cleats, etc.\nRemove all existing ceramic tile walls and floors of all existing apartment bathrooms and all public areas where shown on Drawings.\nRemove all existing tubs, water closets, lavatories, kitchen sinks, and associated trim.\nRemove existing partitions where shown on Drawings to be demolished.\nRemove all existing apartment doors, apartment entry doors, and cellar or basement doors and frames.\nRemove all existing wood base and moldings in apartments.\nRemove all existing window sash, frames, and trim and window treatments. Provide clean masonry openings.\nRemove all existing linoleum and tile flooring in apartments.\nRemove all existing closet shelving, clothes poles, and window shades.\nRemove all finish materials from all partitions shown on Drawings as “existing to remain” and from the interior face of exterior masonry walls.\nRemove all existing lath and plaster ceilings.\nRemove existing finish wood flooring and sub-flooring in all apartments.\nRemove burglar bars, grills, and swing gates at all windows.\nRemove existing exterior and interior stairs where shown on Drawings.\nRemove all existing exterior doors, frames, and trim.\nRemove existing materials at sealed-up windows and doors openings. Provide clean masonry openings ready to receive new work.\nRemove all existing storefronts and entrance door assemblies.\nRemove all existing ceiling materials in public hall areas and stairwells. Remove existing public hall walls where shown to be demolished.\nRemove existing paint from public hall steel","cbCaijFHo53sPpjT","https://ap.wps.com/l/cbCaijFHo53sPpjT","docx",138611,"English","# SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT\n## Salvage and recycle scope for non-hazardous waste\n# SECTION 024119 – SELECTIVE STRUCTURE DEMOLITION\n## Utility disconnection and demolition sequencing\n## Temporary facilities and protection measures\n## Removal of existing structural, exterior, and MEP components\n## Disposal and site housekeeping","[{\"question\":\"What waste materials must be salvaged and recycled under Section 017419?\",\"answer\":\"Non-hazardous demolition and construction waste must be salvaged and recycled, including concrete, wood joists/studs/trim, miscellaneous steel, doors and frames, windows and glazing, plumbing fixtures and piping components, and specified electrical and mechanical equipment. It also covers masonry/CMU, untreated wood materials, gypsum board, insulation, and uncontaminated packaging materials.\"},{\"question\":\"What is required before selective structure demolition begins?\",\"answer\":\"All building utilities must be disconnected before any removal or demolition is commenced by the mechanical trades.\"},{\"question\":\"What site protection and temporary requirements are included during demolition?\",\"answer\":\"A temporary sidewalk shed must be provided for the duration of construction contract work. Demolition work also requires protection of exposed wall areas until new sills are installed, plus temporary shoring before commencement of demolition.\"}]","DIVISION 01 - GENERAL REQUIREMENTS - SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT | DOCX"]