[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-564967-105":3,"detail-sidebar-cat-1-en-105":80,"doc-detail-564967-en":126},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","decade-table-standard-electronic-decade-value-tables-resistance-value-series-reference","Decade Table - Standard Electronic Decade Value Tables - Resistance Value Series Reference","","Provides standard electronic decade value tables used in electronic design, listing preferred resistor number series associated with specific tolerance ranges. Explains how E12 (±10%), E24 (±2% and ±5%), E96 (±1%), and E192 (±0.1%, ±0.25%, ±0.5%) are defined within a decade and how successive values relate by approximate scaling factors. Includes a decade value matrix and guidance that standard values are encouraged for stocking programs, with intermediate values available by special order.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/general/","General",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/decade-table-standard-electronic-decade-value-tables-resistance-value-series-reference/564967/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/decade-table-standard-electronic-decade-value-tables-resistance-value-series-reference/564967.png","ImageObject",442,249,{"name":42,"@type":43},"Pentious","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-27","2026-10-12",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What are the E12, E24, E96, and E192 series in the decade table?","Question",{"text":62,"@type":63},"The document defines number series used as preferred values in electronic design. E12 corresponds to ±10%, E24 to ±2% and ±5%, E96 to ±1%, and E192 to ±0.1%, ±0.25% and ±0.5% within a decade range.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"How are successive values within a decade series related?",{"text":67,"@type":63},"Successive values within a decade series are related by an approximate scaling factor: 12√10 for E12, 24√10 for E24, 96√10 for E96, and 192√10 for E192.",{"name":69,"@type":60,"acceptedAnswer":70},"Can intermediate resistor values outside the listed standard series be ordered?",{"text":71,"@type":63},"Yes. Use of standard values is encouraged for stocking programs, but intermediate values can be specially ordered where permitted, with the document advising to consult the factory.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},564967,1792086596,{"code":4,"msg":81,"data":82},"success",[83,88,93,98,103,108,113,118,123],{"id":84,"doc_module":22,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},11,"Presentations",90,"presentations",{"id":89,"doc_module":22,"doc_module_name":25,"category_name":90,"show_sort_weight":91,"slug":92},12,"Resumes",80,"resumes",{"id":94,"doc_module":22,"doc_module_name":25,"category_name":95,"show_sort_weight":96,"slug":97},14,"Invoices",70,"invoices",{"id":99,"doc_module":22,"doc_module_name":25,"category_name":100,"show_sort_weight":101,"slug":102},15,"Posters",60,"posters",{"id":104,"doc_module":22,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},16,"Social Media",50,"social-media",{"id":109,"doc_module":22,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},17,"Forms",40,"forms",{"id":114,"doc_module":22,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},18,"Letters",30,"letters",{"id":119,"doc_module":22,"doc_module_name":25,"category_name":120,"show_sort_weight":121,"slug":122},21,"Paper Templates",5,"papers-templates",{"id":124,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":4,"slug":125},158,"general-158",{"code":4,"msg":81,"data":127},{"doc_id":78,"user_id":128,"nickname":42,"user_avatar":129,"doc_module":22,"category_id":124,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":135,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":136,"faqs":137,"seo_title":138,"seo_description":12,"update_tm":139,"read_time":4},1374404730887,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Decade Table  \nVishay Dale  \nStandard Electronic Decade Value Tables  \n\n| STANDARD DECADE RESISTANCE VALUES |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| The following table lists four established number series which are used as preferred values in electronic design. Each series is shown under an associated value of tolerance % . The number series under the ± 10 % column is known as the E12 Series because there are 12 standard values within a decade range. ± 2 % and ± 5 % utilize the E24 Series, ± 1 % uses E96 and ± 0.1 %, ± 0.25 % and ± 0.5 % use E192 . Successive values within a decade series are related (approximately) by a factor of 12 10 for the E12 Series, 24 10 for the E24 Series, 96 10 for the E96 Series and 192 10 for the E192 Series.\u003Cbr>Use of standard values is encouraged because stocking programs are designed around them. However, intermediate values can be special ordered where permitted. Consult factory. |  |  |  |  |  |  |\n| ± 0.1 % | ± 0.1 % | ± 0.1 % | ± 0.1 % | ± 0.1 % | ± 0.1 % |  |\n| ± 0.25 % | ± 0.25 % | ± 0.25 % | ± 0.25 % | ± 0.25 % | ± 0.25 % | ± 2 % |\n| ± 0.5 % ± 1 % | ± 0.5 % ± 1 % | ± 0.5 % ± 1 % | ± 0.5 % ± 1 % | ± 0.5 % ± 1 % | ± 0.5 % ± 1 % | ± 5 % ± 10 % |\n| 10.0 10.0 | 14.7 14.7 | 21.5 21.5 | 31.6 31.6 | 46.4 46.4 | 68.1 68.1 | 10 10 |\n| 10.1 | 14.9 | 21.8 | 32.0 | 47.0 | 69.0 | 11 - |\n| 10.2 10.2 | 15.0 15.0 | 22.1 22.1 | 32.4 32.4 | 47.5 47.5 | 69.8 69.8 | 12 12 |\n| 10.4 | 15.2 | 22.3 | 32.8 | 48.1 | 70.6 | 13 - |\n| 10.5 10.5 | 15.4 15.4 | 22.6 22.6 | 33.2 33.2 | 48.7 48.7 | 71.5 71.5 | 15 15 |\n| 10.6 | 15.6 | 22.9 | 33.6 | 49.3 | 72.3 | 16 - |\n| 10.7 10.7 | 15.8 15.8 | 23.2 23.2 | 34.0 34.0 | 49.9 49.9 | 73.2 73.2 | 18 18 |\n| 10.9 | 16.0 | 23.4 | 34.4 | 50.5 | 74.1 | 20 - |\n| 11.0 11.0 | 16.2 16.2 | 23.7 23.7 | 34.8 34.8 | 51.1 51.1 | 75.0 75.0 | 22 22 |\n| 11.1 | 16.4 | 24.0 | 35.2 | 51.7 | 75.9 | 24 - |\n| 11.3 11.3 | 16.5 16.5 | 24.3 24.3 | 35.7 35.7 | 52.3 52.3 | 76.8 76.8 | 27 27 |\n| 11.4 | 16.7 | 24.6 | 36.1 | 53.0 | 77.7 | 30 - |\n| 11.5 11.5 | 16.9 16.9 | 24.9 24.9 | 36.5 36.5 | 53.6 53.6 | 78.7 78.7 | 33 33 |\n| 11.7 | 17.2 | 25.2 | 37.0 | 54.2 | 79.6 | 36 - |\n| 11.8 11.8 | 17.4 17.4 | 25.5 25.5 | 37.4 37.4 | 54.9 54.9 | 80.6 80.6 | 39 39 |\n| 12.0 | 17.6 | 25.8 | 37.9 | 55.6 | 81.6 | 43 - |\n| 12.1 12.1 | 17.8 17.8 | 26.1 26.1 | 38.3 38.3 | 56.2 56.2 | 82.5 82.5 | 47 47 |\n| 12.3 | 18.0 | 26.4 | 38.8 | 56.9 | 83.5 | 51 - |\n| 12.4 12.4 | 18.2 18.2 | 26.7 26.7 | 39.2 39.2 | 57.6 57.6 | 84.5 84.5 | 56 56 |\n| 12.6 | 18.4 | 27.1 | 39.7 | 58.3 | 85.6 | 62 - |\n| 12.7 12.7 | 18.7 18.7 | 27.4 27.4 | 40.2 40.2 | 59.0 59.0 | 86.6 86.6 | 68 68 |\n| 12.9 | 18.9 | 27.7 | 40.7 | 59.7 | 87.6 | 75 - |\n| 13.0 13.0 | 19.1 19.1 | 28.0 28.0 | 41.2 41.2 | 60.4 60.4 | 88.7 88.7 | 82 82 |\n| 13.2 | 19.3 | 28.4 | 41.7 | 61.2 | 89.8 | 91 - |\n| 13.3 13.3 | 19.6 19.6 | 28.7 28.7 | 42.2 42.2 | 61.9 61.9 | 90.9 90.9 |  |\n| 13.5 | 19.8 | 29.1 | 42.7 | 62.6 | 92.0 |  |\n| 13.7 13.7 | 20.0 20.0 | 29.4 29.4 | 43.2 43.2 | 63.4 63.4 | 93.1 93.1 |  |\n| 13.8 | 20.3 | 29.8 | 43.7 | 64.2 | 94.2 |  |\n| 14.0 14.0 | 20.5 20.5 | 30.1 30.1 | 44.2 44.2 | 64.9 64.9 | 95.3 95.3 |  |\n| 14.2 | 20.8 | 30.5 | 44.8 | 65.7 | 96.5 |  |\n| 14.3 14.3 | 21.0 21.0 | 30.9 30.9 | 45.3 45.3 | 66.5 66.5 | 97.6 97.6 |  |\n| 14.5 | 21.3 | 31.2 | 45.9 | 67.3 | 98.8 |  |\n\nStandard resistance values are obtained from the decade table by multiplying by powers of 10. As an example, 13.3 can represent Ω, 133 Ω, 1.33 kΩ, 13.3 kΩ, 133 kΩ, 1.33 MΩ.  \nDocument Number 31001 For technical questions, contact: [ff2aresistors@vishay.com](ff2aresistors@vishay.com) [www.vishay.com](www.vishay.com)  \n[Revision 04-Oct-06 335](Revision 04-Oct-06 335)","cbCaitDoN2XeL3aa","https://ap.wps.com/l/cbCaitDoN2XeL3aa","pdf",59200,"English","# Overview\n## Tolerance-based number series (E12, E24, E96, E192)\n# Decade value tables\n## Stocking preference and special orders\n# Notes and references","[{\"question\":\"What are the E12, E24, E96, and E192 series in the decade table?\",\"answer\":\"The document defines number series used as preferred values in electronic design. E12 corresponds to ±10%, E24 to ±2% and ±5%, E96 to ±1%, and E192 to ±0.1%, ±0.25% and ±0.5% within a decade range.\"},{\"question\":\"How are successive values within a decade series related?\",\"answer\":\"Successive values within a decade series are related by an approximate scaling factor: 12√10 for E12, 24√10 for E24, 96√10 for E96, and 192√10 for E192.\"},{\"question\":\"Can intermediate resistor values outside the listed standard series be ordered?\",\"answer\":\"Yes. Use of standard values is encouraged for stocking programs, but intermediate values can be specially ordered where permitted, with the document advising to consult the factory.\"}]","Decade Table - Standard Electronic Decade Value Tables - Resistance Value Series Reference | PDF",1791845438]