[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-173127-105":53,"doc-detail-173127-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","data-communications-cabling-specifications-scope","Data Communications Cabling Specifications - SCOPE","","Section scope defines the complete work for high-speed data transmission cabling systems, covering wire and cable, racks, patch panels, connecting devices, support D-rings, and all installation and testing activities. The contractor furnishes and installs all required materials exactly as specified and submits them for compliance inspection before use. It also specifies communications outlet installations, multi-mode and single-mode fiber in communication rooms, and required rack hardware, patch panels quantities, and consistent UTP category selection (Cat5e or Cat6).",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":51,"@type":70,"position":76},"https://docshare.wps.com/template/general/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/data-communications-cabling-specifications-scope/173127/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/data-communications-cabling-specifications-scope/173127.png","ImageObject",442,249,{"name":88,"@type":89},"Emma Wilson","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/octet-stream","2026-10-01","2026-09-01",true,{"@type":98,"interactionType":99,"userInteractionCount":79},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What work is included in the scope for the wiring system?","Question",{"text":108,"@type":109},"The scope includes wire and cable, racks, patch panels, connecting devices, cable support D-rings, plus all installation and testing for wiring systems used for high-speed data transmission.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"Are substitutions allowed for the specified cabling materials?",{"text":113,"@type":109},"No. The contractor must use the exact materials specified with no equivalent substitutions, and Cat6 alternate materials require written approval before use.",{"name":115,"@type":106,"acceptedAnswer":116},"How are cable certification tests required to be submitted and performed?",{"text":117,"@type":109},"UTP certification must be performed with a Fluke DTX1800 and include detailed test metrics in .FLW format, while fiber certification must use an OTDR tested from each end and include required wavelengths in .TRC format; results must be provided to TTU via DVD or CD.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},173127,1788300194,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":50,"category_name":51,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":79,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":125,"read_time":140},3848291630094,"https://eur-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","PART 1 - GENERAL\nSCOPE\nDescription: The work of this Section includes the wire, cable, racks, patch panels, connecting devices, cable support D-rings, all installation and testing for wiring systems and components to be used as signal pathways for high-speed data transmission.\nThe Contractor shall furnish and install all wiring and components to support data systems.\nThe Contractor shall use the exact materials specified (no equivalent material substitutions are allowed) and shall submit for compliance inspection by Telecommunications Services prior to commencing installation or use of materials.\nInstallation of all communication outlets at offices, exam rooms, etc. as indicated on the drawings.\nInstallation of multi-mode and single-mode fiber in Communications Rooms.\nThe Contractor shall furnish and install self-supporting, 19” EIA floor racks, cable pathways, and power distribution units in each Communications Room.\nThe Contractor shall furnish and install patch panels in the racks in each Communications Room.  Provide the quantity of patch panels as required to connect all data cables.\nThe wiring components shall consist of jacks, faceplates, wire and all accessories required to properly install the wiring and devices.\nThe UTP wiring, jacks, and patch panels shall be of a consistent category throughout the entire installation – either ALL Cat5e, or ALL Cat6.  Use of Cat6 (*Alternate) materials shall be requested in writing to the Managing Director of Telecommunications for approval.\nThe Contractor shall furnish all the labor and materials to perform all the work required for the complete and prompt execution of items described or shown in or reasonably implied in the drawings and specifications.\nThe Contractor agrees to furnish the specified products and services in strict accordance with the conditions, requirements, drawings, and specifications.\nTTU FACILITIES AND PLANT OPERATIONS OPERATING PROCEDURES\nAll cabling projects must conform to TTU OP 61.12 (http://www.depts.ttu.edu/opmanual/OP61.12.pdf) in its entirety.  If the contractor has any problems accessing this document, notify Telecommunications Services and a copy of TTU OP 61.12 will be provided.\nAll contractors are required to submit a $100 deposit for each key issued for interstitial and mechanical room access.  This deposit will be refunded when the issued key is returned.\nSUBMITTALS\nGeneral: Submit each item in this Article according to the Conditions of the Contract and Specification Sections.\nProduct Data: Submit for review complete manufacturer's product cut sheets for each component specified; these must include detailed manufacturer's specifications and data on features, ratings, and performance. Include dimensioned plan and elevation views of components. Show access and working-space requirements.\nQualifications:\nCabling contractor must provide at least 5 references with names and contact information of previous installations of $10,000 or more.\nCabling contractor must provide documentation showing 10 years or more experience installing data network cabling.\nCabling contractor must provide proof of certifications (i.e. DCIC) and/or proof of data training received within the last five years.\nCable Certification Tests: Submit complete field test reports to Telecommunications for review and acceptance as described herein. UTP cable certification must be performed with a Fluke DTX1800 tester. Tests results shall be identified by the corresponding labeled Cable ID and must include wire map, resistance, length, propagation delay, impedance, return loss, attenuation, and cross-talk. Test results must be provided in a .FLW file format. Fiber cable certification must be performed with an OTDR (Optical Time-Domain Reflectometer), tested from each end. Test results must include both wavelengths for single mode fiber (1310nm/1550nm), and multimode fiber (850nm/1300nm). Test results must be provided in a .TRC file format.  Test results described herein shall be provide","cbCaisNvBQwtfKIu","https://ap.wps.com/l/cbCaisNvBQwtfKIu","doc",1623754,23,"English","# PART 1 - GENERAL\n## Scope\n## TTU Facilities and Plant Operations Operating Procedures\n## Submittals\n## Cable Schedules\n## Listing\n# PART 2 - PRODUCTS\n## Racks and Hardware\n## Communications Rooms","[{\"question\":\"What work is included in the scope for the wiring system?\",\"answer\":\"The scope includes wire and cable, racks, patch panels, connecting devices, cable support D-rings, plus all installation and testing for wiring systems used for high-speed data transmission.\"},{\"question\":\"Are substitutions allowed for the specified cabling materials?\",\"answer\":\"No. The contractor must use the exact materials specified with no equivalent substitutions, and Cat6 alternate materials require written approval before use.\"},{\"question\":\"How are cable certification tests required to be submitted and performed?\",\"answer\":\"UTP certification must be performed with a Fluke DTX1800 and include detailed test metrics in .FLW format, while fiber certification must use an OTDR tested from each end and include required wavelengths in .TRC format; results must be provided to TTU via DVD or CD.\"}]","Data Communications Cabling Specifications - SCOPE | DOC",8]