[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-159543-105":53,"doc-detail-159543-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","ct-analyzer-ordering-information-firmware-packages-and-upgrades","CT Analyzer - Ordering Information - Firmware Packages and Upgrades","","Ordering Information details CT Analyzer firmware package tiers and upgrade paths (Basic, Standard, Advanced, IEEE Protection) with specific part numbers and IEC/IEEE support notes. The document lists core firmware capabilities such as composite error, ratio error and phase displacement testing, excitation characteristic and knee-point determination, automatic assessment against selected standards, and transient behavior measurement. It also specifies included/optional assessment rules, accessories, grounding and coaxial cable kits, and PC software features for guided test execution, test reports, and result simulation.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":11,"@type":70,"position":76},"https://docshare.wps.com/template/presentations/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/ct-analyzer-ordering-information-firmware-packages-and-upgrades/159543/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/ct-analyzer-ordering-information-firmware-packages-and-upgrades/159543.png","ImageObject",442,249,{"name":88,"@type":89},"Chumphorn","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-09-22","2026-08-29",true,{"@type":98,"interactionType":99,"userInteractionCount":76},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"What firmware packages are offered for the CT Analyzer?","Question",{"text":108,"@type":109},"The document presents Basic, Standard, Advanced, and IEEE Protection firmware packages as the main tiers.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"Which upgrade paths are supported between packages?",{"text":113,"@type":109},"It specifies upgrade routes such as Basic→Standard, Basic→Advanced, Standard→Advanced, and IEEE Protection→Advanced, each with its own package identifier.",{"name":115,"@type":106,"acceptedAnswer":116},"What key CT measurement and assessment functions are described?",{"text":117,"@type":109},"Firmware features include composite error measurements, ratio error and phase displacement tests, excitation and knee-point voltage determination, CT winding resistance and accuracy measurements, and automated CT performance assessment according to selected IEC/IEEE standards.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},159543,1788019402,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":8,"category_name":11,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":76,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":135,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":125,"read_time":76},2336475401981,"https://ap-avatar.wpscdn.com/avatar/22000c94efd8d5204d?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786935347598174694","Ordering Information CT Analyzer  \nFirmware Packages and Upgrades  \nBasic  \nP0000853  \nStandard P0000846  \nAdvanced P0000848  \nIEEE Protection P0000847  \n\n| In brief | |\n| --- | --- |\n| F i rmwa re Features | CT secondary wiring phase and polarity measurements ■ ■ ■ ■\u003Cbr>Composite error measurements for nominal current ■ ■ ■ ■\u003Cbr>Ratio error and phase displacement measurement for no load and rated load ■ ■ ■ ■\u003Cbr>Measurement of excitation characteristics (voltage/current)\u003Cbr>> Knee point voltage from 1 V up to 4 kV ■ ■ ■ ■\u003Cbr>> Knee point voltage from 0.1 V up to 40 kV – – ■ –\u003Cbr>> Automated calculation of knee points according to IEC and IEEE ■ ■ ■ ■\u003Cbr>> Comparison of excitation curve to a reference curve – ■ ■ ■\u003Cbr>CT winding resistance measurement (primary and secondary) ■ ■ ■ ■\u003Cbr>CT accuracy measurements (ratio error and phase displacement depending on burden and current)\u003Cbr>> IEC 61869 / 60044, or IEEE C57.13 classes ≥ 0.3 – ■ ■ –\u003Cbr>> IEC 61869 / 60044, or IEEE C57.13 classes ≥ 0.1 – – ■ –\u003Cbr>> Customized standards or local / national standards – – ■ –\u003Cbr>Automatic assessment of CT performance according to the selected standard – ■ ■ ■\u003Cbr>Customization of assessment rules (for example implementation of national standards) – –1 ■ –\u003Cbr>Composite error measurement for overcurrent conditions (ALF/ALFi, FS/FSi for IEC and Vb for IEEE) – ■ ■ ■\u003Cbr>Determination of ALF and FS for IEC or Vb for IEEE – ■ ■ ■\u003Cbr>Secondary burden measurement ■ ■ ■ ■\u003Cbr>„Nameplate guesser“ function for CTs with unknown data – ■ ■ ■\u003Cbr>Simulation of measured data – – ■ ■\u003Cbr>Measurement of transient behavior of TPS, TPX, TPY and TPZ type CTs – – ■ –\u003Cbr>Determination of the transient dimensioning factor (Ktd) – – ■ –\u003Cbr>Considering Duty Cycles C-O / C-O-C-O, for example auto-reclosure system – – ■ –\u003Cbr>Automatic demagnetization of the CT after the test ■ ■ ■ ■\u003Cbr>Remote control with CT Analyzer Suite software ■ ■ ■ ■\u003Cbr>Flexible manual current and voltage source (QuickTest) – ■ ■ ■\u003Cbr>Testing of CTs for line frequencies of 50 Hz ■ ■ ■ –\u003Cbr>Testing of CTs for line frequencies of 60 Hz ■ ■ ■ ■\u003Cbr>CT SB2 (switch box) for measurements of CTs with up to 6 taps, including accessories □ □ □ ■\u003Cbr>CPOL3 for verifying the correct polarity of the secondary wiring along all connection points □ □ □ □\u003Cbr>RemAlyzer software for measuring the residual magnetism in CTs □ □ □ □ |\n\nFirmware  \nUpgrades  \nBasic-> Standard Upgrades Basic to Standard Package P0006569  \nBasic-> Advanced Upgrades Basic to Advanced Package P0006570  \nStandard-> Advanced Upgrades Standard to Advanced Package P0006566  \nIEEE Protection-> Advanced Upgrades IEEE Protection to Advanced Package P0006567  \n1 IEC 61869-6 not supported ■ included □ optional – not included  \nBasic, Standard and Advanced packages  \nItem  \n| Hardware |  |\n| --- | --- |\n| CT Analyzer | 1 |\n| Cables and accessories |  |\n\nGrounding cable (6 m, 6 mm2 / 20 ft, 0.01 sq in) with connection clamp 1  Coaxial cables (3 m / 10 ft) 2  Coaxial cable (10 m / 33 ft) 1  Crocodile clamps for plugs 4 mm / 0.2 in, opening width: 20 mm / 0.8 in ( 2 × red, 2 × black) 4   \nFlexible terminal adapters for plugs 4 mm / 0.2 in 12   \nUSB cable 1   \nUSB 3.0 Compact flash card reader (design may change) 1   \nCompact flash card 1   \nCT Analyzer carry bag 1   \nCT Analyzer PC software toolset 1   \nBattery clamps for plugs 4 mm / 0.2 in 2   \nPower cable 1   \nClass 0.5 CT for training purposes . FS 5, ratio = 300:5 1  User manual (available on DVD) 1  Calibration certificate 1  Set of two Kelvin clamp adapters 1   \nIEEE Protection package  \nItem  \n| Hardware |  |\n| --- | --- |\n| CT Analyzer | 1 |\n| CT SB2 switch box for measurements on CTs with up to 6 taps | 1 |\n| Cables and accessories |  |\n\nGrounding cable (6 m, 6 mm2 / 20 ft, 0.01 sq in) with connection clamp 1  Coaxial cable (6 m / 20 ft) 1  Coaxial cable (10 m / 33 ft) 1   \nCoaxial cable (15 m / 49 ft) 1   \n4-pole coaxial cable (7 m / 22 ft for connecting CT SB2 to burden 1   \n6-pole coaxial cable f","cbCaifoWRhRQL7a5","https://ap.wps.com/l/cbCaifoWRhRQL7a5","pdf",492476,8,"English","# Firmware Packages and Upgrades\n## Basic and Standard upgrades\n## Advanced and IEEE Protection upgrades\n## Included support notes (IEC 61869-6)","[{\"question\":\"What firmware packages are offered for the CT Analyzer?\",\"answer\":\"The document presents Basic, Standard, Advanced, and IEEE Protection firmware packages as the main tiers.\"},{\"question\":\"Which upgrade paths are supported between packages?\",\"answer\":\"It specifies upgrade routes such as Basic→Standard, Basic→Advanced, Standard→Advanced, and IEEE Protection→Advanced, each with its own package identifier.\"},{\"question\":\"What key CT measurement and assessment functions are described?\",\"answer\":\"Firmware features include composite error measurements, ratio error and phase displacement tests, excitation and knee-point voltage determination, CT winding resistance and accuracy measurements, and automated CT performance assessment according to selected IEC/IEEE standards.\"}]","CT Analyzer - Ordering Information - Firmware Packages and Upgrades | PDF"]