[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-detail-169498-en":3,"doc-seo-169498-105":30,"detail-sidebar-cat-1-en-105":92},{"code":4,"msg":5,"data":6},0,"success",{"doc_id":7,"user_id":8,"nickname":9,"user_avatar":10,"doc_module":11,"category_id":12,"category_name":13,"doc_title":14,"doc_description":15,"doc_content":16,"file_id":17,"file_url":18,"file_type":19,"file_size":20,"view_count":11,"is_deleted":4,"is_public":11,"is_downloadable":11,"audit_status":11,"page_count":21,"language":22,"language_code":23,"site_id":24,"html_lang":23,"table_of_contents":25,"faqs":26,"seo_title":27,"seo_description":15,"update_tm":28,"read_time":29},169498,8796093062539,"8796093062539","",1,11,"Presentations","Cooling Tower Maintenance Program and Plan Template - Version 1.0 - Guide to developing a compliant plan","A structured template for developing a cooling tower maintenance program and plan in line with New York State Sanitary Code Subpart 4-1. It guides facility owners in capturing essential program components through sections covering facility information, process description, staff roles, program validation, and implementation. The plan further details onsite monitoring schedules and response protocols, maintenance operations, operational procedures (startup/shutdown, disinfection, cleaning, contingencies), along with required program chemistry and testing elements. Examples support baseline minimum information and case-by-case expansion.","\u0003Cooling Tower Maintenance Program and Plan Template\u0004\nVersion: 1.0\nNew York State Department of Health\nBureau of Water Supply Protection\nAugust 2017\n\u000f\nIntroduction\nThis document is designed as a guide to the development of a maintenance program and plan for a cooling tower. The sections included in this template represent a survey of procedures currently used in the field and aim to capture the essential building blocks required for a comprehensive program document. The sections included serve as guidance and are therefore not specified by Subpart 4-1 of the New York State Sanitary Code.\nThe complete text of the regulation can be found here: \u0013 HYPERLINK \"https://regs.health.ny.gov/content/part-4-protection-against-legionella\" \u0014https://regs.health.ny.gov/content/part-4-protection-against-legionella\u0015.\nDisclaimer\nThis is a suggested template for a maintenance program and plan required by Subpart 4-1 of the New York State Sanitary Code.  The examples provided should not be considered as recommendations from the New York State Department of Health for treatment options. This material should be considered the minimum suggested information used to define the maintenance program and plan; each cooling tower and situation is unique and an expansion of elements on a case by case basis may be required.\n\u000f\n\u0003Cooling Tower Maintenance Program and Plan Template\u0004\nPrepared for:\nPrepared by:\nEffective Date:\n\u0003Contents\n\u0013 TOC \\o \"1-3\" \\h \\z \\u \u0014\u0013 HYPERLINK \\l \"_Toc479771119\" \u0014Section 1.\tFacility Information\t\u0013 PAGEREF _Toc479771119 \\h \u00144\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771120\" \u00141.1\tCooling Tower Location\t\u0013 PAGEREF _Toc479771120 \\h \u00144\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771121\" \u00141.2\tDeveloper of Maintenance plan (company)\t\u0013 PAGEREF _Toc479771121 \\h \u00144\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771122\" \u00141.3\tEffective Date of Maintenance Plan\t\u0013 PAGEREF _Toc479771122 \\h \u00144\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771123\" \u00141.4\tCooling Tower Information\t\u0013 PAGEREF _Toc479771123 \\h \u00144\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771124\" \u00141.5\tAdditional narrative:\t\u0013 PAGEREF _Toc479771124 \\h \u00145\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771125\" \u0014Section 2.\tProcess Description\t\u0013 PAGEREF _Toc479771125 \\h \u00146\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771126\" \u00142.1\tTower System Description\t\u0013 PAGEREF _Toc479771126 \\h \u00146\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771127\" \u00142.1.1\tFilter information (if used)\t\u0013 PAGEREF _Toc479771127 \\h \u00146\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771128\" \u00142.2\tProcess Schematic\t\u0013 PAGEREF _Toc479771128 \\h \u00147\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771129\" \u00142.3\tHeat source Description\t\u0013 PAGEREF _Toc479771129 \\h \u00147\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771130\" \u00142.4\tControl Elements\t\u0013 PAGEREF _Toc479771130 \\h \u00148\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771131\" \u0014Section 3.\tPersonnel Roles and Responsibilities\t\u0013 PAGEREF _Toc479771131 \\h \u00149\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771132\" \u00143.1\tPersonnel\t\u0013 PAGEREF _Toc479771132 \\h \u00149\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771133\" \u00143.2\tResponsibilities and Roles\t\u0013 PAGEREF _Toc479771133 \\h \u001410\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771134\" \u0014Section 4.\tProgram Validation\t\u0013 PAGEREF _Toc479771134 \\h \u001412\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771135\" \u0014Section 5.\tProgram Implementation\t\u0013 PAGEREF _Toc479771135 \\h \u001413\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771136\" \u00145.1\tProgram Chemistry\t\u0013 PAGEREF _Toc479771136 \\h \u001413\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771137\" \u00145.1.1\tCorrosion inhibitors\t\u0013 PAGEREF _Toc479771137 \\h \u001413\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771138\" \u00145.1.2\tBiocides/disinfectants\t\u0013 PAGEREF _Toc479771138 \\h \u001413\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771139\" \u00145.1.3\tDispersants/detergents\t\u0013 PAGEREF _Toc479771139 \\h \u001413\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771140\" \u00145.2\tProgram Materials\t\u0013 PAGEREF _Toc479771140 \\h \u001413\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771141\" \u00145.3\tProgram Testing/Sampling Devices\t\u0013 PAGEREF _Toc479771141 \\h \u001413\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771142\" \u00145.3.1\tProgram Chemical Testing\t\u0013 PAGEREF _Toc479771142 \\h \u001414\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771143\" \u00145.3.2\tProgram Bacterial culture devices (e.g. Dipslides)\t\u0013 PAGEREF _Toc479771143 \\h \u001414\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771144\" \u00145.4\tProgram Administration Equipment\t\u0013 PAGEREF _Toc479771144 \\h \u001414\u0015\u0015\n\u0013 HYPERLINK \\l \"_Toc479771145\" \u00145.4.1\tData generation/Sampling & ","cbCaijr9iJTSo5rf","https://ap.wps.com/l/cbCaijr9iJTSo5rf","docx",238458,29,"English","en",105,"# Introduction\n# Section 1. Facility Information\n## Cooling Tower Location\n## Developer of Maintenance plan (company)\n# Section 2. Process Description\n## Tower System Description\n## Process Schematic\n## Heat source Description\n# Section 3. Personnel Roles and Responsibilities\n## Personnel\n## Responsibilities and Roles\n# Section 4. Program Validation\n# Section 5. Program Implementation\n## Program Chemistry\n## Program Testing/Sampling Devices\n## Program Administration Equipment\n# Section 6. Onsite Monitoring Procedures\n## Monitoring Schedule\n## Monitoring Methods and Procedures\n## Monitoring Response Protocols\n# Section 7. Onsite Maintenance Operations\n# Section 8. Cooling Tower Operation Procedures\n## Season Startup Procedure\n## Season Shutdown Procedure\n## Cooling Tower Cleaning Procedure\n## Cooling Tower Online Disinfection Procedure\n## Cooling Tower Emergency Disinfection Procedure","[{\"question\":\"What is the purpose of the Cooling Tower Maintenance Program and Plan Template?\",\"answer\":\"It provides guidance for developing a comprehensive maintenance program and plan for a cooling tower, capturing essential building blocks used in the field.\"},{\"question\":\"Which types of information does the template include?\",\"answer\":\"It includes facility information, tower/process descriptions, personnel roles, program validation, chemistry and materials, testing and sampling devices, and administration equipment.\"},{\"question\":\"How does the template address monitoring and onsite response?\",\"answer\":\"It defines onsite monitoring schedules, methods and procedures, monitoring response protocols, and a monitoring log to support implementation and corrective actions.\"}]","Cooling Tower Maintenance Program and Plan Template - Version 1.0 - Guide to developing a compliant plan | DOCX",1788255529,10,{"code":4,"msg":31,"data":32},"ok",{"site_id":24,"language":23,"slug":33,"title":14,"keywords":10,"description":15,"schema_data":34,"social_meta":87,"head_meta":89,"extra_data":91,"updated_unix":28},"cooling-tower-maintenance-program-and-plan-template-version-10-guide-to-developing-a-compliant-plan",{"@graph":35,"@context":86},[36,53,69],{"@type":37,"itemListElement":38},"BreadcrumbList",[39,43,47,50],{"item":40,"name":41,"@type":42,"position":11},"https://docshare.wps.com","Home","ListItem",{"item":44,"name":45,"@type":42,"position":46},"https://docshare.wps.com/template/","Template",2,{"item":48,"name":13,"@type":42,"position":49},"https://docshare.wps.com/template/presentations/",3,{"item":51,"name":14,"@type":42,"position":52},"https://docshare.wps.com/template/cooling-tower-maintenance-program-and-plan-template-version-10-guide-to-developing-a-compliant-plan/169498/",4,{"url":51,"name":14,"@type":54,"author":55,"headline":14,"publisher":57,"fileFormat":60,"inLanguage":23,"description":15,"dateModified":61,"datePublished":62,"encodingFormat":60,"isAccessibleForFree":63,"interactionStatistic":64},"DigitalDocument",{"name":9,"@type":56},"Person",{"url":40,"name":58,"@type":59},"DocShare","Organization","application/vnd.openxmlformats-officedocument.wordprocessingml.document","2026-09-05","2026-09-01",true,{"@type":65,"interactionType":66,"userInteractionCount":68},"InteractionCounter",{"@type":67},"ViewAction",5,{"@type":70,"mainEntity":71},"FAQPage",[72,78,82],{"name":73,"@type":74,"acceptedAnswer":75},"What is the purpose of the Cooling Tower Maintenance Program and Plan Template?","Question",{"text":76,"@type":77},"It provides guidance for developing a comprehensive maintenance program and plan for a cooling tower, capturing essential building blocks used in the field.","Answer",{"name":79,"@type":74,"acceptedAnswer":80},"Which types of information does the template include?",{"text":81,"@type":77},"It includes facility information, tower/process descriptions, personnel roles, program validation, chemistry and materials, testing and sampling devices, and administration equipment.",{"name":83,"@type":74,"acceptedAnswer":84},"How does the template address monitoring and onsite response?",{"text":85,"@type":77},"It defines onsite monitoring schedules, methods and procedures, monitoring response protocols, and a monitoring log to support implementation and corrective actions.","https://schema.org",{"og:url":51,"og:type":88,"og:title":14,"og:site_name":58,"og:description":15},"article",{"robots":90,"canonical":51},"index,follow",{"doc_id":7,"site_id":24},{"code":4,"msg":5,"data":93},[94,97,102,107,112,117,122,127,131],{"id":12,"doc_module":11,"doc_module_name":45,"category_name":13,"show_sort_weight":95,"slug":96},90,"presentations",{"id":98,"doc_module":11,"doc_module_name":45,"category_name":99,"show_sort_weight":100,"slug":101},12,"Resumes",80,"resumes",{"id":103,"doc_module":11,"doc_module_name":45,"category_name":104,"show_sort_weight":105,"slug":106},14,"Invoices",70,"invoices",{"id":108,"doc_module":11,"doc_module_name":45,"category_name":109,"show_sort_weight":110,"slug":111},15,"Posters",60,"posters",{"id":113,"doc_module":11,"doc_module_name":45,"category_name":114,"show_sort_weight":115,"slug":116},16,"Social Media",50,"social-media",{"id":118,"doc_module":11,"doc_module_name":45,"category_name":119,"show_sort_weight":120,"slug":121},17,"Forms",40,"forms",{"id":123,"doc_module":11,"doc_module_name":45,"category_name":124,"show_sort_weight":125,"slug":126},18,"Letters",30,"letters",{"id":128,"doc_module":11,"doc_module_name":45,"category_name":129,"show_sort_weight":68,"slug":130},21,"Paper Templates","papers-templates",{"id":132,"doc_module":11,"doc_module_name":45,"category_name":133,"show_sort_weight":4,"slug":134},158,"General","general-158"]