[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-392722-105":3,"detail-sidebar-cat-1-en-105":80,"doc-detail-392722-en":126},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","consul-system-monitor-datasheet","Consul System Monitor Datasheet","","Consul™ is a system monitor typically deployed in a Network Operation Center (NOC) to correlate and manage data from Medius units across a network. It provides a program alert dashboard with a consolidated view, supports multiple Medius units, and can automatically generate and email PDF reports on a user-defined schedule. The datasheet details applications for alert analysis, QoE monitoring, specifications including interfaces, dimensions, power, and environmental limits, plus ordering and service options.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/general/","General",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/consul-system-monitor-datasheet/392722/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/consul-system-monitor-datasheet/392722.png","ImageObject",442,249,{"name":42,"@type":43},"Ivy","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-20","2026-09-25",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What does Consul™ do in a Network Operation Center (NOC)?","Question",{"text":62,"@type":63},"Consul™ correlates and manages data from Medius units across the network, using a program alert dashboard for consolidated monitoring and alerts.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"How are reports generated and delivered in Consul™?",{"text":67,"@type":63},"Reports can be generated automatically and emailed in PDF format according to a user-defined schedule.",{"name":69,"@type":60,"acceptedAnswer":70},"What environmental limits and interface support are listed for the Consul System Monitor?",{"text":71,"@type":63},"The datasheet specifies maximum operating temperature of 35 °C, max humidity of 85%, and browser support for Firefox, Safari, and Internet Explorer, with Ethernet-based interfaces for inputs and management.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},392722,1791317993,{"code":4,"msg":81,"data":82},"success",[83,88,93,98,103,108,113,118,123],{"id":84,"doc_module":22,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},11,"Presentations",90,"presentations",{"id":89,"doc_module":22,"doc_module_name":25,"category_name":90,"show_sort_weight":91,"slug":92},12,"Resumes",80,"resumes",{"id":94,"doc_module":22,"doc_module_name":25,"category_name":95,"show_sort_weight":96,"slug":97},14,"Invoices",70,"invoices",{"id":99,"doc_module":22,"doc_module_name":25,"category_name":100,"show_sort_weight":101,"slug":102},15,"Posters",60,"posters",{"id":104,"doc_module":22,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},16,"Social Media",50,"social-media",{"id":109,"doc_module":22,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},17,"Forms",40,"forms",{"id":114,"doc_module":22,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},18,"Letters",30,"letters",{"id":119,"doc_module":22,"doc_module_name":25,"category_name":120,"show_sort_weight":121,"slug":122},21,"Paper Templates",5,"papers-templates",{"id":124,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":4,"slug":125},158,"general-158",{"code":4,"msg":81,"data":127},{"doc_id":78,"user_id":128,"nickname":42,"user_avatar":129,"doc_module":22,"category_id":124,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":135,"language":136,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":12,"update_tm":140,"read_time":26},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","Digital Content Monitors  \nConsul System Monitor • VNM-CON Datasheet  \nConsul™ is typically located at a Network Operation Center (NOC) and provides an ideal solution for correlating and managing data from Medius units located throughout the network.  \nKey features  \n Program alert dashboard provides single consolidated view of all programs across all Medius units  \n Supports multiple Medius units  \n Automatic report generation and e-mail in PDF format per user-defined schedule  \nApplications  \n Generate alert analysis reports with roll-up data collected from multiple Medius units  \nQoE monitoring across networks  \nConsul™ aggregates reports and trending data from multiple Medius units and offers video service providers an effective way of utilizing monitoring data in large-scale monitoring deployments.  \nConsul can be used by service providers to gain a quick understanding of the quality of experience they are providing on a local, regional, or national level. Key features of Consul include a program alert dashboard that gives a single consolidated view of all programs monitored across all Medius units. The dashboard quickly alerts service providers to issues occurring across the network. In addition, Consul provides an understanding of the video quality degradation from location to location and identifying the top offending programs at each location.  \nCapturing detailed QoE (Quality of Experience) information is a function of the Consul advanced reporting package. The reporting capabilities allow each user (i.e. , a national NOC/operation center) to generate customized reports that provide as much or as focused detail as required, from monthly high-level reports for executive staff to immediate notices for technicians as incidents occur.  \nUsers can create a schedule template so that reports can be generated automatically and e-mailed to designated recipients. Examples of the reports include alert counts by location, trending reports, and distributions by alert type.  \nConsul System Monitor Datasheet  \nConsul is typically located at a regional or national Network Operation Center (NOC) and provides an ideal solution for correlating and managing data from Medius units located throughout the network.  \nConsul System Monitor Datasheet  \nSpecifications  \nInterface characteristics  \nBrowser support Firefox, Safari, and Internet Explorer  \n\n| MPEG/IP input port | 1000BASE-T Ethernet interface |\n| --- | --- |\n| Management port | 1000BASE-T Ethernet interface |\n| Physical characteristics |  |\n| Dimensions |  |\n| Height | 50.8 mm (2 in.) |\n| Width | 432 mm (17 in.) |\n| Depth | 381 mm (15 in.) |\n| Weight (net) | 9.2 kg (20.3 lb.) |\n| Power requirements | 100-240 VAC, 50-60 Hz |\n| Environmental characteristics\u003Cbr>Max storage temperature 70 °C |  |\n| Max operating temperature | 35 °C |\n| Max humidity | 85% |\n\nConsul System Monitor Datasheet  \nOrdering information  \nModels VNM-CON  \nInstrument options Power plug options  \nOpt. A0  \nOpt. A1  \nOpt. A2  \nOpt. A3  \nOpt. A4  \nOpt. A5  \nOpt. A6  \nOpt. A10  \nOpt. A11  \nOpt. A12  \nOpt. A99  \nConsul System Monitor  \nNorth America power plug (115 V, 60 Hz) Universal Euro power plug (220 V, 50 Hz) United Kingdom power plug (240 V, 50 Hz) Australia power plug (240 V, 50 Hz) North America power plug (240 V, 50 Hz) Switzerland power plug (220 V, 50 Hz) Japan power plug (100 V, 50/60 Hz) China power plug (50 Hz)  \nIndia power plug (50 Hz)  \nBrazil power plug (60 Hz) No power cord  \nService options  \nVNM-SUP  \nVNM-SUP-REN  \nOne-year service support  \nRenewal of one-year product support  \nTektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.  \nConsul System Monitor Datasheet  \nConsul System Monitor Datasheet  \nASEAN / Australasia (65) 6356 3900  \nBelgium 00800 2255 4835*  \nCentral East Europe and the Baltics +41 52 675 3777 Finland +41 52 675 3777  \nHong Kong 400 820 5835  \nJapan 81 (3) 6714 3086  \nMiddle East, Asia, and North Africa +41 52 675 3777 People's Republic of Chin","cbCaiopRkVHJhbRq","https://ap.wps.com/l/cbCaiopRkVHJhbRq","pdf",402753,6,"English","# Key features\n# Applications\n# Specifications\n## Interface characteristics\n## Physical characteristics\n## Environmental characteristics\n# Ordering information","[{\"question\":\"What does Consul™ do in a Network Operation Center (NOC)?\",\"answer\":\"Consul™ correlates and manages data from Medius units across the network, using a program alert dashboard for consolidated monitoring and alerts.\"},{\"question\":\"How are reports generated and delivered in Consul™?\",\"answer\":\"Reports can be generated automatically and emailed in PDF format according to a user-defined schedule.\"},{\"question\":\"What environmental limits and interface support are listed for the Consul System Monitor?\",\"answer\":\"The datasheet specifies maximum operating temperature of 35 °C, max humidity of 85%, and browser support for Firefox, Safari, and Internet Explorer, with Ethernet-based interfaces for inputs and management.\"}]","Consul System Monitor Datasheet | PDF",1790373312]