[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-detail-241363-en":53,"doc-seo-241363-105":75},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":5,"data":54},{"doc_id":55,"user_id":56,"nickname":57,"user_avatar":58,"doc_module":9,"category_id":8,"category_name":11,"doc_title":59,"doc_description":60,"doc_content":61,"file_id":62,"file_url":63,"file_type":64,"file_size":65,"view_count":15,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":66,"language":67,"language_code":68,"site_id":69,"html_lang":68,"table_of_contents":70,"faqs":71,"seo_title":72,"seo_description":60,"update_tm":73,"read_time":74},241363,2336474466412,"\tJames","https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","CITY OF SANTA ROSA REGIONAL WATER REUSE ENERGY OPTIMIZATION PLAN - July 2019","The City of Santa Rosa Regional Water Reuse Energy Optimization Plan (July 2019) provides an energy-focused evaluation framework for key reclaimed water and treatment operations. It includes executive summary guidance and multiple technical memoranda covering process energy audits for wastewater treatment, compost facilities, recycled water systems, and related amendments. The plan also documents attachment materials such as pond layout, allowed recycled water uses, pump station improvement status, background information, and exclusions from analysis, supporting prioritized recommendations for energy efficiency and system improvements.","CITY OF SANTA ROSA REGIONAL WATER REUSE ENERGY OPTIMIZATION PLAN  \nJULY 2019  \nCity of Santa Rosa Water Department  \nIn Conjunction with Kennedy/Jenks Consultants  \nCity of Santa Rosa Regional Water Reuse Energy Optimization Plan  \nPREPARED BY  \nIN CONJUNCTION WITH  \nKennedy/Jenks Consultants  \nJuly 2O19  \nTABLE OF CONTENTS  \nExecutive Summary ES-1  \nTechnical Memorandum \\#1: Laguna Wastewater Treatment Plant Process Energy Audit 1-1  \n1.1 Recommendations .............................................................................................................. 1-1  \n1.2 Background......................................................................................................................... 1-4  \n1.3 Overview of Audit Methodology ......................................................................................... 1-8  \n1.4 Detailed Descriptions of Recommended Energy Efficiency Measures ............................ 1-13  \n1.5 Detailed Descriptions of Process Improvements ............................................................. 1-25  \nTechnical Memorandum \\#2: Compost Facility Energy Audit 2-1  \n2.1 Recommendations ...............................................................................................................2-1  \n2.2 Background .........................................................................................................................2-2  \n2.3 Overview of Audit Methodology ..........................................................................................2-4  \n2.4 Detailed Descriptions of Recommended Energy Efficiency Measures ............................... 2-5  \n2.5 Detailed Descriptions of Energy Efficiency Measures Not Recommended ...................... 2-10  \nTechnical Memorandum \\#3: Recycled Water System Energy Audit 3-1  \n3.1 Recommendation ................................................................................................................. 3-1  \n3.2 Background .........................................................................................................................3-2  \n3.3 Overview of Audit Methodology .......................................................................................... 3-5  \n3.4 Detailed Descriptions of Recommended Energy Efficiency Measures ............................. 3-11  \n3.5 Detailed Descriptions of Energy Efficiency Measures Not Recommended ...................... 3-15  \nAttachment A: Recycled Water Storage Pond Layout ..................................................... 3-16  \nAttachment B: Recycled Water Uses Allowed in California ........................................... 3-16  \nAttachment C: Recycled Water Pump Station Improvements as of April 2014 ............. 3-17  \nAttachment D: Background Recycled Water Pump Station Information ....................... 3-20  \nAttachment E: Recycled Water Pumps Excluded from Analysis .................................... 3-22  \nTechnical Memorandum \\#3a (Amendment): Reclamation System Energy Audit 3a-1  \n3a. 1 Recommendation ............................................................................................................ 3a-1  \n2 Background..................................................................................................................... 3a-2  \n3 Detailed Descriptions of Energy Efficiency Measures Not Recommended ................... 3a-5  \nTechnical Memorandum \\#4: Geysers Energy Audit 4-1  \n4.1 Recommendation .................................................................................................................4-1  \n4.2 Background .........................................................................................................................4-2  \n4.3 Overview of Audit Methodology .......................................................................................... 4-4  \n4.4 Detailed Descriptions of Recommended Energy Efficiency Measures ............................... 4-7  \n4.5 Detailed Descriptions of Energy ","cbCaivK9wUtxIAFS","https://ap.wps.com/l/cbCaivK9wUtxIAFS","pdf",13473626,213,"English","en",105,"# Executive Summary\n## Technical Memorandum #1: Laguna Wastewater Treatment Plant Process Energy Audit\n## 1.1 Recommendations\n## 1.2 Background\n## 1.3 Overview of Audit Methodology\n## 1.4 Detailed Descriptions of Recommended Energy Efficiency Measures\n## 1.5 Detailed Descriptions of Process Improvements\n## Technical Memorandum #2: Compost Facility Energy Audit\n## 2.1 Recommendations\n## 2.2 Background\n## 2.3 Overview of Audit Methodology\n## 2.4 Detailed Descriptions of Recommended Energy Efficiency Measures\n## 2.5 Detailed Descriptions of Energy Efficiency Measures Not Recommended\n## Technical Memorandum #3: Recycled Water System Energy Audit\n## 3.1 Recommendation\n## 3.2 Background\n## 3.3 Overview of Audit Methodology\n## 3.4 Detailed Descriptions of Recommended Energy Efficiency Measures\n## 3.5 Detailed Descriptions of Energy Efficiency Measures Not Recommended\n## Attachment A: Recycled Water Storage Pond Layout\n## Attachment B: Recycled Water Uses Allowed in California\n## Attachment C: Recycled Water Pump Station Improvements as of April 2014\n## Attachment D: Background Recycled Water Pump Station Information\n## Attachment E: Recycled Water Pumps Excluded from Analysis\n## Technical Memorandum #3a (Amendment): Reclamation System Energy Audit\n## Technical Memorandum #4: Geysers Energy Audit\n## Technical Memorandum #5: Brainstorming Workshop #1 Process and Outcomes\n## Technical Memorandum #6: Laguna Treatment Plant Waste Heat Investigation\n## Technical Memorandum #7: Energy Management Software Investigation","[{\"question\":\"What is the purpose of the Regional Water Reuse Energy Optimization Plan?\",\"answer\":\"It evaluates energy efficiency opportunities across Santa Rosa’s reclaimed water and treatment operations and organizes findings into auditable recommendations and supporting technical materials.\"},{\"question\":\"Which facilities and systems are covered by the technical memoranda?\",\"answer\":\"The plan includes process energy audits for the Laguna Wastewater Treatment Plant, compost facility, and recycled water system, plus an amendment for the reclamation system and audits/investigations related to Geysers, waste heat, and energy management software.\"},{\"question\":\"What information do the attachments provide?\",\"answer\":\"Attachments document practical reference data such as recycled water storage pond layout, allowed recycled water uses in California, pump station improvement status and background information, and lists of pumps excluded from analysis.\"}]","CITY OF SANTA ROSA REGIONAL WATER REUSE ENERGY OPTIMIZATION PLAN - July 2019 | PDF",1789174203,75,{"code":4,"msg":76,"data":77},"ok",{"site_id":69,"language":68,"slug":78,"title":59,"keywords":79,"description":60,"schema_data":80,"social_meta":136,"head_meta":138,"extra_data":140,"updated_unix":141},"city-of-santa-rosa-regional-water-reuse-energy-optimization-plan-july-2019","",{"@graph":81,"@context":135},[82,98,118],{"@type":83,"itemListElement":84},"BreadcrumbList",[85,89,92,95],{"item":86,"name":87,"@type":88,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":90,"name":10,"@type":88,"position":91},"https://docshare.wps.com/template/",2,{"item":93,"name":11,"@type":88,"position":94},"https://docshare.wps.com/template/presentations/",3,{"item":96,"name":59,"@type":88,"position":97},"https://docshare.wps.com/template/city-of-santa-rosa-regional-water-reuse-energy-optimization-plan-july-2019/241363/",4,{"url":96,"name":59,"@type":99,"image":100,"author":105,"headline":59,"publisher":107,"fileFormat":110,"inLanguage":68,"description":60,"dateModified":111,"datePublished":112,"encodingFormat":110,"isAccessibleForFree":113,"interactionStatistic":114},"DigitalDocument",{"url":101,"@type":102,"width":103,"height":104},"https://docshare.wps.com/thumbnails/city-of-santa-rosa-regional-water-reuse-energy-optimization-plan-july-2019/241363.png","ImageObject",442,249,{"name":57,"@type":106},"Person",{"url":86,"name":108,"@type":109},"DocShare","Organization","application/pdf","2026-10-14","2026-09-12",true,{"@type":115,"interactionType":116,"userInteractionCount":15},"InteractionCounter",{"@type":117},"ViewAction",{"@type":119,"mainEntity":120},"FAQPage",[121,127,131],{"name":122,"@type":123,"acceptedAnswer":124},"What is the purpose of the Regional Water Reuse Energy Optimization Plan?","Question",{"text":125,"@type":126},"It evaluates energy efficiency opportunities across Santa Rosa’s reclaimed water and treatment operations and organizes findings into auditable recommendations and supporting technical materials.","Answer",{"name":128,"@type":123,"acceptedAnswer":129},"Which facilities and systems are covered by the technical memoranda?",{"text":130,"@type":126},"The plan includes process energy audits for the Laguna Wastewater Treatment Plant, compost facility, and recycled water system, plus an amendment for the reclamation system and audits/investigations related to Geysers, waste heat, and energy management software.",{"name":132,"@type":123,"acceptedAnswer":133},"What information do the attachments provide?",{"text":134,"@type":126},"Attachments document practical reference data such as recycled water storage pond layout, allowed recycled water uses in California, pump station improvement status and background information, and lists of pumps excluded from analysis.","https://schema.org",{"og:url":96,"og:type":137,"og:title":59,"og:site_name":108,"og:description":60},"article",{"robots":139,"canonical":96},"index,follow",{"doc_id":55,"site_id":69},1791300223]