[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-241332-105":53,"doc-detail-241332-en":126},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":119,"head_meta":121,"extra_data":123,"updated_unix":125},105,"en","christie-eclipse-g3-series-preventive-maintenance-schedule-rev-1-initial-release","Christie Eclipse G3 Series Preventive Maintenance Schedule - Rev 1 - Initial Release","","Christie Eclipse G3 preventive maintenance schedule defining inspection and replacement tasks for different projector system components, organized by interval and duration. The schedule clarifies how to interpret intervals using operational hours or elapsed time, based on an assumed daily 14-hour operation. It includes fields for theater/house, component part/serial numbers, service dates, operating hours, technician name and signature, and check/replace durations. Detailed entries specify what to inspect or replace at milestones such as 5,000 hours/12 months and 10,000 hours/2 years, plus reference documents and service part numbers.",{"@graph":63,"@context":118},[64,80,101],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":11,"@type":70,"position":76},"https://docshare.wps.com/template/presentations/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/christie-eclipse-g3-series-preventive-maintenance-schedule-rev-1-initial-release/241332/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/christie-eclipse-g3-series-preventive-maintenance-schedule-rev-1-initial-release/241332.png","ImageObject",442,249,{"name":88,"@type":89},"Eden","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-11","2026-09-12",true,{"@type":98,"interactionType":99,"userInteractionCount":9},"InteractionCounter",{"@type":100},"ViewAction",{"@type":102,"mainEntity":103},"FAQPage",[104,110,114],{"name":105,"@type":106,"acceptedAnswer":107},"How should the maintenance interval be interpreted in this schedule?","Question",{"text":108,"@type":109},"Intervals are defined either by operational hours or by elapsed time since installation. When both are provided, the interval that occurs first applies.","Answer",{"name":111,"@type":106,"acceptedAnswer":112},"What information is recorded when completing a preventive maintenance (PM)?",{"text":113,"@type":109},"The schedule captures the completion date, system operating hours, technician name and signature, and other signature fields such as the CSE signature.",{"name":115,"@type":106,"acceptedAnswer":116},"What kinds of maintenance actions are included for components in the schedule?",{"text":117,"@type":109},"The schedule specifies inspection PM and replacement PM items, with duration in minutes and notes describing checks (e.g., leaks, cleanliness, dust build-up) and replacement timing.","https://schema.org",{"og:url":78,"og:type":120,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":122,"canonical":78},"index,follow",{"doc_id":124,"site_id":56},241332,1791742475,{"code":4,"msg":5,"data":127},{"doc_id":124,"user_id":128,"nickname":88,"user_avatar":129,"doc_module":9,"category_id":8,"category_name":11,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":135,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":9,"language":136,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":61,"update_tm":140,"read_time":4},1374391974468,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","| | Christie Eclipse G3 Series Preventive Maintenance Schedule\u003Cbr>Applicable to Christie Eclipse G3 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 010-109855-01 Rev 01 |  |  |  |  |  |  |  |  |  |  | Revision | Description |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Theater/House | (Enter Theatre name and house number) | LEGEND |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Interpreting this schedule:\u003Cbr>1. The interval information being presented below is for either operational hours, or time passed since installation-the notes will indicate check/replace intervals in more detail. In the event that both are presented, the interval shall be whichever occurs first.\u003Cbr>2. Alignment of the operational hours, and months/years of time is based on an assumed 14 hours of operation every day. | Rev 01 | Initial Release |  |\n| Projector Part/Serial \\# | (Enter Projector and pedestal part and serial number) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Pedestal Part/Serial \\# | (Enter Projector and pedestal part and serial number) | |  |  |  |  |  |  |  |  |  |  |  |  |  | Inspect |  | |  |  | Clean Record |  | |  |  | Replace Adjust |  |  |  |  |  |  |\n| Server Part/Serial \\# | (Enter Server and Automation part and serial number) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Automation Part/Serial \\# | (Enter Server and Automation part and serial number) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  | Description |  | \u003Cbr>Example\u003Cbr>2,500 hrs/6 months\u003Cbr>5,000 hrs/12 months\u003Cbr>7,500 hrs/18 months\u003Cbr>10,000 hrs/2 years\u003Cbr>12,500 hrs/2.5 years\u003Cbr>15,000 hrs/3 years\u003Cbr>17,500 hrs/3.5 years\u003Cbr>20,000 hrs/4 years\u003Cbr>22,500 hrs/4.5 years\u003Cbr>25,000 hrs/5 years\u003Cbr>27,500 hrs/5.5 years\u003Cbr>30,0000 hrs/6 years\u003Cbr>32,500 hrs/6.5 years\u003Cbr>35,000 hrs/7 years\u003Cbr>37,500 hrs/7.5 years\u003Cbr>40,000 hrs/8.0 years\u003Cbr>42,500 hrs/8.5 years\u003Cbr>45,000 hrs/9.0 years\u003Cbr>47,500 hrs/9.5 years\u003Cbr>50,000 hrs/10.0 years |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Service Part\u003Cbr>Number | Reference documents | Web |\n|  |  | Date Complete |  |  | 14/1/2025 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Enter date PM was completed |  |  |  |\n|  |  | Operating Hours |  |  | 2000 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Enter system hours PM was completed |  |  |  |\n|  |  | Tech Name and Signature |  |  | John Doe |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | CSE Signature |  |  |  |\n|  |  | Inspection PM\u003Cbr>(duration in\u003Cbr>minutes) | Replacement\u003Cbr>PM (duration in\u003Cbr>minutes) |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Notes |  |  |  |\n| General | Prep for PM work | 10 | 10 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Light Engines | Light Engine Coolant Lines | 2 | 2 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Inspect every 5,000 h / 12 mo. Check for kinks in coolant lines. Check for evidence of coolant leaks at quick disconnects and any connection points. | n/a | 020-103315-XX Christie LIT MAN USR TruLife+\u003Cbr>020-104013-XX Christie LIT MAN SERV Eclipse G3 020-104012-XX Christie LIT GUID SET Eclipse G3 020-103948-XX Christie LIT INST SHT SMC Chiller 060 HRS060 Operations Manual HRX-OM-R005\u003Cbr>020-104081-XX Christie LIT TECH REF ENT Video Formats | www chr ist iedigital com\u003Cbr>. .\u003Cbr>|\n|  | DMD Waterblocks (3x) | 2 | 2 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Inspect every 5,000 h / 12 mo. Check DMD waterblocks and hose connections for leaks. | n/a |  |  |\n|  | Inta","cbCaiucN104M9ZvX","https://ap.wps.com/l/cbCaiucN104M9ZvX","pdf",297459,8,"English","# Preventive Maintenance Schedule Overview\n## Legend and Interval Interpretation\n## Schedule Header Information (Theater/House, Revision)\n## Projector/Component Part and Serial Entries\n## Service Record (Date Complete, Operating Hours, Signatures)\n## Maintenance Tasks by Component Group\n## Reference Documents and Service Part Numbers","[{\"question\":\"How should the maintenance interval be interpreted in this schedule?\",\"answer\":\"Intervals are defined either by operational hours or by elapsed time since installation. When both are provided, the interval that occurs first applies.\"},{\"question\":\"What information is recorded when completing a preventive maintenance (PM)?\",\"answer\":\"The schedule captures the completion date, system operating hours, technician name and signature, and other signature fields such as the CSE signature.\"},{\"question\":\"What kinds of maintenance actions are included for components in the schedule?\",\"answer\":\"The schedule specifies inspection PM and replacement PM items, with duration in minutes and notes describing checks (e.g., leaks, cleanliness, dust build-up) and replacement timing.\"}]","Christie Eclipse G3 Series Preventive Maintenance Schedule - Rev 1 - Initial Release | PDF",1789173804]