[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-237659-105":3,"detail-sidebar-cat-1-en-105":81,"doc-detail-237659-en":126},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","cata-log-rpp-remote-power-panels-power-distribution-unit-smart-flexible-power-to-your-data-center","CATA LOG - RPP Remote Power Panels, Power Distribution Unit - Smart, Flexible power to your data center","","CATA LOG presents ABB’s configurable Remote Power Panel (RPP) and Power Distribution Unit for data center power needs, emphasizing continuous operation, energy efficiency, and space saving. It highlights SMISSLINE busbar technology enabling safe plug-in and replacement under voltage without power interruption, finger-safe protection (IP2XB), and a portfolio supporting circuit breakers and residual current devices up to 63A. The catalog also covers modular flexibility, advanced energy monitoring and branch monitoring for transparency and diagnostics, and installation speed through a modular certified system and integrated solutions for connectivity and cyber security.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/presentations/","Presentations",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/cata-log-rpp-remote-power-panels-power-distribution-unit-smart-flexible-power-to-your-data-center/237659/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/cata-log-rpp-remote-power-panels-power-distribution-unit-smart-flexible-power-to-your-data-center/237659.png","ImageObject",442,249,{"name":42,"@type":43},"Mason","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29","2026-09-11",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",12,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What problem does ABB’s RPP target for data centers?","Question",{"text":63,"@type":64},"It is engineered to meet data center power requirements for continuous operation, energy efficiency, space saving, modularity, and flexibility, while improving power monitoring and distribution safety and reliability.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How does the SMISSLINE busbar technology support continuous operation?",{"text":68,"@type":64},"It allows load-free devices and components to be plugged on and off under voltage without power interruption and without needing additional personal protective equipment, while requiring compliance with national regulations and safety rules.",{"name":70,"@type":61,"acceptedAnswer":71},"What benefits are highlighted for installation and project speed?",{"text":72,"@type":64},"The catalog emphasizes user-friendliness, simpler wiring methods, modular pluggable busbar architecture certified to IEC 61439-2, and reduced assembly time through solutions like SMISSLINE touch proof systems, Direct Feed, and retrofit-suitable branch monitoring.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},237659,1791729593,{"code":4,"msg":82,"data":83},"success",[84,88,92,97,102,107,112,117,122],{"id":85,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":86,"slug":87},11,90,"presentations",{"id":55,"doc_module":22,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Resumes",80,"resumes",{"id":93,"doc_module":22,"doc_module_name":25,"category_name":94,"show_sort_weight":95,"slug":96},14,"Invoices",70,"invoices",{"id":98,"doc_module":22,"doc_module_name":25,"category_name":99,"show_sort_weight":100,"slug":101},15,"Posters",60,"posters",{"id":103,"doc_module":22,"doc_module_name":25,"category_name":104,"show_sort_weight":105,"slug":106},16,"Social Media",50,"social-media",{"id":108,"doc_module":22,"doc_module_name":25,"category_name":109,"show_sort_weight":110,"slug":111},17,"Forms",40,"forms",{"id":113,"doc_module":22,"doc_module_name":25,"category_name":114,"show_sort_weight":115,"slug":116},18,"Letters",30,"letters",{"id":118,"doc_module":22,"doc_module_name":25,"category_name":119,"show_sort_weight":120,"slug":121},21,"Paper Templates",5,"papers-templates",{"id":123,"doc_module":22,"doc_module_name":25,"category_name":124,"show_sort_weight":4,"slug":125},158,"General","general-158",{"code":4,"msg":82,"data":127},{"doc_id":79,"user_id":128,"nickname":42,"user_avatar":129,"doc_module":22,"category_id":85,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":135,"language":136,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":12,"update_tm":140,"read_time":141},5909887256941,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","—  \nCATA LOG  \nRPP Remote Power Panels, Power Distribution Unit  \nSmart, Flexible power to your data center  \n• Intelligent data needs intelligent power  \n• Unique power density, giving you more in less space  \n• 50% less footprint, 100% redundancy  \nA K K 1 0 8 4 6 6 A 4 4 2 3  \n—  \nTable of contents  \n004–005  \n006–009 010–011  \n012–013  \n014–015  \n016–017  \n018019019 020–023  \nKey areas of focus The advantages  \nValue proposition and benefits for stakeholders  \nSystem overview  \nTechnical Features at a glance Short Summary on Main Technical Aspects Coordination  \nTemperature Considerations Support Tools  \nHow to get your RPPpreconfigured?  \n—  \nKey areas of focus  \nOverview  \nFulfilling the stringent needs for Data Center Power when it comes to continuous operation, energy efficiency, space saving, modularity and flexibility, is achieved with ABB’s RPP which is engineered specially to respond to the complexity and criticality of Data Center application.  \nABB’s configurable Remote Power Panel (RPP)  \nhelps to meet the demands of power-intensive  \napplications, delivering unsurpassed power  \nmonitoring and distribution in a safe, reliable,  \nspace-saving footprint.  \nThe configurable RPP is the ideal solution for  \nData Center engineers, saving the time for  \nplanning and drawing of the RPP.  \nContinuous operation  \nInside ABB’s Remote Power Panel (RPP) the  \nSMISSLINE busbar technology is used.  \nIt ensures continuous operation and load-free  \ndevices and components can be plugged on  \nand off under voltage with no need for  \nadditional personal protective equipment to  \nguard against electrical hazards. (Note:  \nnational regulation and safety rules need to be  \nfulfilled at any time) . The pluggable socket  \nsystem is completely finger safe (IP2XB) .  \nThe SMISSLINE TP product portfolio provides a  \nvariety of circuit breakers and residual current  \ndevices up to 63A in different variations. With  \nthe touch proof SMISSLINE busbar system  \ndevices can easily be changed under voltage  \nwithout any power interruption.  \nEnergy efficiency  \nThe ABB range of connected devices have been  \nspecifically developed to meet requirements of  \nenergy and asset management. Monitoring and  \ncontrolling the energy flow in electrical  \ndistribution is made easy with these devices.  \nThe network analyzers and branch monitoring  \nproduct help users to detect risks at an early  \nstage thanks to total transparency, constant  \ndiagnostics and real time notifications.  \nSpace Saving  \nModularity/Flexibility  \n Continous Operations  \nSpace saving  \nVertical structure saves space in the RPP and the input wiring is already integrated into the pluggable socket system.  \nThis reduces the number of cables in the RPP and results in a clear and organized panel.  \nModularity and flexibility.  \nSMISSLINE, multi-pole devices can be positioned anywhere.  \nThe system provides flexible architecture and many different power supply options.  \nThe ability to incorporate last-minute changes promptly is likewise a great advantage.  \nNew devices can be integrated easily and safely.  \nThe system can be expanded quickly and is more efficient and fully compatible with existing installations.“Pay as you grow” is made easy by installing empty power distribution units and populate them with devices when your customers rent the rack space.  \n6 R PP REMOTE POWER PANELS , POWER DISTRIBUTION UNIT  \nThe advantages  \nEasy to install  \nThe RPP focusses on user-friendliness: The SMISSLINE system consists of main busbars anda wide range of MCB’s that can be easily changed without power interruptions.  \nThe wiring method simplifies the overall installation and allows you to add any kind of protection device, metering or connection device.  \nThe SMISSLINE Direct Feed connects the MCCB  \nand the SMISSLINE system in a compact and reliable way and there is no need for additional cabling.  \nAdding devices can be done by the panel builder during the manufacturing phase or later by the ","cbCaiisW5WkTsfVf","https://ap.wps.com/l/cbCaiisW5WkTsfVf","pdf",8154770,24,"English","# Table of contents\n## Key areas of focus - The advantages\n## Value proposition and benefits for stakeholders\n## System overview\n## Technical Features at a glance - Short Summary on Main Technical Aspects\n## Coordination\n## Temperature Considerations\n## Support Tools\n## How to get your RPP preconfigured?\n# Key areas of focus\n## Overview - Continuous operation\n## Energy efficiency\n## Space Saving - Modularity/Flexibility\n## The advantages - Easy to install\n## Speed up your projects\n## Unique power density\n## Optimum Interface - Simplifies connectivity","[{\"question\":\"What problem does ABB’s RPP target for data centers?\",\"answer\":\"It is engineered to meet data center power requirements for continuous operation, energy efficiency, space saving, modularity, and flexibility, while improving power monitoring and distribution safety and reliability.\"},{\"question\":\"How does the SMISSLINE busbar technology support continuous operation?\",\"answer\":\"It allows load-free devices and components to be plugged on and off under voltage without power interruption and without needing additional personal protective equipment, while requiring compliance with national regulations and safety rules.\"},{\"question\":\"What benefits are highlighted for installation and project speed?\",\"answer\":\"The catalog emphasizes user-friendliness, simpler wiring methods, modular pluggable busbar architecture certified to IEC 61439-2, and reduced assembly time through solutions like SMISSLINE touch proof systems, Direct Feed, and retrofit-suitable branch monitoring.\"}]","CATA LOG - RPP Remote Power Panels, Power Distribution Unit - Smart, Flexible power to your data center | PDF",1789114015,8]