[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-563520-105":3,"detail-sidebar-cat-1-en-105":81,"doc-detail-563520-en":127},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","broiler-temperature-management-chart-day-by-day-targets","Broiler Temperature Management Chart - Day-by-Day Targets","","Day-by-day broiler temperature management chart listing target temperature ranges, winter and summer set temperatures in °C and corresponding set temperatures in °F, plus relative humidity bands. Each day also specifies air inlet condition, minimum air speed, and an ON/OFF cycle percentage to guide ventilation and airflow control. The schedule progresses from higher early targets to gradually lower ranges, adjusting humidity, inlet settings, speeds, and cycling frequency.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/template/","Template",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/template/general/","General",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/template/broiler-temperature-management-chart-day-by-day-targets/563520/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/broiler-temperature-management-chart-day-by-day-targets/563520.png","ImageObject",442,249,{"name":42,"@type":43},"kopisore","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-22","2026-10-12",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What information does the chart provide for each day of broiler rearing?","Question",{"text":63,"@type":64},"For each day, it lists target temperature ranges, winter and summer set temperatures in °C and °F, relative humidity, air inlet setting, minimum air speed, and the ON/OFF cycle percentage.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How are winter and summer set temperatures shown in the chart?",{"text":68,"@type":64},"The chart provides a set temperature column for winter and summer, with an equivalent set temperature in °F alongside the °C targets.",{"name":70,"@type":61,"acceptedAnswer":71},"How does the ON/OFF cycle percentage change across the rearing period?",{"text":72,"@type":64},"It starts at 0 or 10% in early days, then increases stepwise later (e.g., up to 20%, 30%, and beyond), reflecting a gradual change in ventilation cycling needs as conditions evolve.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},563520,1792083174,{"code":4,"msg":82,"data":83},"success",[84,89,94,99,104,109,114,119,124],{"id":85,"doc_module":22,"doc_module_name":25,"category_name":86,"show_sort_weight":87,"slug":88},11,"Presentations",90,"presentations",{"id":90,"doc_module":22,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},12,"Resumes",80,"resumes",{"id":95,"doc_module":22,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},14,"Invoices",70,"invoices",{"id":100,"doc_module":22,"doc_module_name":25,"category_name":101,"show_sort_weight":102,"slug":103},15,"Posters",60,"posters",{"id":105,"doc_module":22,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},16,"Social Media",50,"social-media",{"id":110,"doc_module":22,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},17,"Forms",40,"forms",{"id":115,"doc_module":22,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},18,"Letters",30,"letters",{"id":120,"doc_module":22,"doc_module_name":25,"category_name":121,"show_sort_weight":122,"slug":123},21,"Paper Templates",5,"papers-templates",{"id":125,"doc_module":22,"doc_module_name":25,"category_name":29,"show_sort_weight":4,"slug":126},158,"general-158",{"code":4,"msg":82,"data":128},{"doc_id":79,"user_id":129,"nickname":42,"user_avatar":130,"doc_module":22,"category_id":125,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":131,"file_id":132,"file_url":133,"file_type":134,"file_size":135,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":136,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":137,"faqs":138,"seo_title":139,"seo_description":12,"update_tm":140,"read_time":4},962090880963,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","| DAY | TARGET\u003Cbr>TEMP (°C) | SET TEMP(° F)\u003Cbr>WINTER SUMMER |  | REL. HUM\u003Cbr>(%) | AIR INLET\u003Cbr>(\u003C\u003C) | MIN. SPEED | ON/OFF\u003Cbr>CYCLE (%) |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| 1 | 30-34 | 32 | 29.0 | 70-72 | Closed | 30 | 0 Infiltration |\n| 2 | 30-34 | 32 | 29.0 | 70-72 | Closed | 30 | 0 Infiltration |\n| 3 | 30-34 | 32 | 29.0 | 70-72 | Closed | 30 | 0 Infiltration |\n| 4 | 30-34 | 32 | 29.0 | 70-72 | Closed | 30 | 0 Infiltration |\n| 5 | 30-34 | 32 | 29.0 | 70-72 | Closed | 30 | 0 Infiltration |\n| 6 | 30-34 | 32 | 29 | 70-72 | Closed | 30 | 0 Infiltration |\n| 7 | 30-34 | 32 | 29 | 70-72 | Closed | 30 | 10 |\n| 8 | 29-33 | 30 | 28 | 60-70 | Closed | 30 | 10 |\n| 9 | 29-33 | 30 | 28 | 60-70 | Closed | 30 | 10 |\n| 10 | 29-33 | 30 | 28 | 60-70 | Closed | 30 | 10 |\n| 11 | 29-33 | 30 | 28 | 60-70 | Closed | 30 | 20 |\n| 12 | 29-33 | 30 | 28 | 60-70 | Closed | 30 | 20 |\n| 13 | 29-33 | 30 | 28 | 60-70 | Closed | 30 | 20 |\n| 14 | 28-32 | 29 | 27 | 60-70 | Closed | 30 | 20 |\n| 15 | 28-32 | 29 | 27 | 50-60 | ¼ | 30 | 30 |\n| 16 | 28-32 | 29 | 27 | 50-60 | ¼ | 30 | 30 |\n| 17 | 28-32 | 29 | 27 | 50-60 | ¼ | 30 | 30 |\n| 18 | 27-31 | 28 | 26 | 50-60 | ¼ | 30 | 30 |\n| 19 | 27-31 | 28 | 26 | 50-60 | ¼ | 30 | 30 |\n| 20 | 27-31 | 28 | 26 | 50-60 | ¼ | 30 | 30 |\n| 21 | 26-30 | 27 | 25 | 50-60 | ¼ | 30 | 30 |\n| 22 | 26-30 | 27 | 25 | 50-60 | ¼ | 30 | 50 |\n| 23 | 25-29 | 26 | 24 | 50-60 | ¼ | 30 | 50 |\n| 24 | 25-29 | 26 | 24 | 50-60 | ¼ | 30 | 50 |\n| 25 | 24-28 | 25 | 23 | 50-60 | ¼ | 30 | 50 |\n| 26 | 24-28 | 25 | 23 | 50-60 | ¼ | 30 | 50 |\n| 27 | 23-28 | 24 | 22 | 50-60 | ¼ | 30 | 50 |\n| 28 | 23-28 | 24 | 22 | 50-60 | ½ | 30 | 65 |\n| 29 | 23-27 | 24 | 21 | 50-60 | ½ | 30 | 65 |\n| 30 | 22-27 | 23 | 21 | 50-60 | ½ | 30 | 65 |\n| 31 | 22-27 | 23 | 21 | 50-60 | ½ | 30 | 65 |\n| 32 | 22-27 | 23 | 21 | 50-60 | ½ | 30 | 65 |\n| 33 | 21-26 | 22 | 20 | 50-60 | ½ | 30 | 65 |\n| 34 | 21-26 | 22 | 20 | 50-60 | ½ | 30 | 65 |\n| 35 | 21-26 | 22 | 20 | 50-60 | ½ | 30 | 75 |\n| 36 | 20-26 | 21 | 19 | 50-60 | ½ | 30 | 75 |\n| 37 | 20-25 | 21 | 19 | 50-60 | ½ | 30 | 75 |\n| 38 | 20-25 | 21 | 19 | 50-60 | ½ | 30 | 75 |\n| 39 | 19-25 | 20 | 18 | 50-60 | ½ | 30 | 75 |\n| 40 | 19-25 | 20 | 18 | 50-60 | ½ | 30 | 80 |\n| 41 | 19-25 | 20 | 18 | 50-60 | ½ | 30 | 80 |\n| 42 | 18-24 | 20 | 17 | 50-60 | ½ | 30 | 80 |","cbCaiou5D7Zzi05B","https://ap.wps.com/l/cbCaiou5D7Zzi05B","pdf",150223,"English","# Daily Temperature Targets\n## Winter and Summer Set Temperatures\n## Relative Humidity, Air Inlet, and Air Speed\n## ON/OFF Cycle Percentage","[{\"question\":\"What information does the chart provide for each day of broiler rearing?\",\"answer\":\"For each day, it lists target temperature ranges, winter and summer set temperatures in °C and °F, relative humidity, air inlet setting, minimum air speed, and the ON/OFF cycle percentage.\"},{\"question\":\"How are winter and summer set temperatures shown in the chart?\",\"answer\":\"The chart provides a set temperature column for winter and summer, with an equivalent set temperature in °F alongside the °C targets.\"},{\"question\":\"How does the ON/OFF cycle percentage change across the rearing period?\",\"answer\":\"It starts at 0 or 10% in early days, then increases stepwise later (e.g., up to 20%, 30%, and beyond), reflecting a gradual change in ventilation cycling needs as conditions evolve.\"}]","Broiler Temperature Management Chart - Day-by-Day Targets | PDF",1791836190]