[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-en-105":3,"doc-seo-564831-105":53,"doc-detail-564831-en":127},{"code":4,"msg":5,"data":6},0,"success",[7,14,19,24,29,34,39,44,49],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":12,"slug":13},11,1,"Template","Presentations",90,"presentations",{"id":15,"doc_module":9,"doc_module_name":10,"category_name":16,"show_sort_weight":17,"slug":18},12,"Resumes",80,"resumes",{"id":20,"doc_module":9,"doc_module_name":10,"category_name":21,"show_sort_weight":22,"slug":23},14,"Invoices",70,"invoices",{"id":25,"doc_module":9,"doc_module_name":10,"category_name":26,"show_sort_weight":27,"slug":28},15,"Posters",60,"posters",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":32,"slug":33},16,"Social Media",50,"social-media",{"id":35,"doc_module":9,"doc_module_name":10,"category_name":36,"show_sort_weight":37,"slug":38},17,"Forms",40,"forms",{"id":40,"doc_module":9,"doc_module_name":10,"category_name":41,"show_sort_weight":42,"slug":43},18,"Letters",30,"letters",{"id":45,"doc_module":9,"doc_module_name":10,"category_name":46,"show_sort_weight":47,"slug":48},21,"Paper Templates",5,"papers-templates",{"id":50,"doc_module":9,"doc_module_name":10,"category_name":51,"show_sort_weight":4,"slug":52},158,"General","general-158",{"code":4,"msg":54,"data":55},"ok",{"site_id":56,"language":57,"slug":58,"title":59,"keywords":60,"description":61,"schema_data":62,"social_meta":120,"head_meta":122,"extra_data":124,"updated_unix":126},105,"en","ansiiec-symbols-training-note","ANSI/IEC Symbols - Training Note","","Training note compiling ANSI and IEC device/switch/contact symbol notations and their corresponding codes for industrial control and protection elements. Tables map ANSI symbol names to ANSI codes and align them with IEC 617 symbols and IEC codes, including contactor/relay contacts, timed contacts (ON-delay and OFF-delay), selector switches, pushbuttons, limit/proximity/pressure/temperature level switches, indicating lights, coils, counters, circuit breakers, fuses, terminals, and emergency stop buttons. Includes copyright and source references.",{"@graph":63,"@context":119},[64,80,102],{"@type":65,"itemListElement":66},"BreadcrumbList",[67,71,74,77],{"item":68,"name":69,"@type":70,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":72,"name":10,"@type":70,"position":73},"https://docshare.wps.com/template/",2,{"item":75,"name":11,"@type":70,"position":76},"https://docshare.wps.com/template/presentations/",3,{"item":78,"name":59,"@type":70,"position":79},"https://docshare.wps.com/template/ansiiec-symbols-training-note/564831/",4,{"url":78,"name":59,"@type":81,"image":82,"author":87,"headline":59,"publisher":90,"fileFormat":93,"inLanguage":57,"description":61,"dateModified":94,"datePublished":95,"encodingFormat":93,"isAccessibleForFree":96,"interactionStatistic":97},"DigitalDocument",{"url":83,"@type":84,"width":85,"height":86},"https://docshare.wps.com/thumbnails/ansiiec-symbols-training-note/564831.png","ImageObject",442,249,{"name":88,"@type":89},"4398046744996","Person",{"url":68,"name":91,"@type":92},"DocShare","Organization","application/pdf","2026-10-22","2026-10-12",true,{"@type":98,"interactionType":99,"userInteractionCount":101},"InteractionCounter",{"@type":100},"ViewAction",6,{"@type":103,"mainEntity":104},"FAQPage",[105,111,115],{"name":106,"@type":107,"acceptedAnswer":108},"What do the tables provide for each symbol?","Question",{"text":109,"@type":110},"Each entry lists an ANSI symbol and ANSI code, then aligns it with the IEC 617 symbol and IEC code, followed by a short description.","Answer",{"name":112,"@type":107,"acceptedAnswer":113},"Which timed contact types are referenced?",{"text":114,"@type":110},"The note includes timed contact open/closed variants for ON-delay (TDE) and OFF-delay (TDD), labeled for both normally open and normally closed behavior.",{"name":116,"@type":107,"acceptedAnswer":117},"Does the reference include emergency stop and protection devices?",{"text":118,"@type":110},"Yes. It includes an emergency stop button (mushroom head) description and references protection devices such as circuit breaker (QF) and fuse/protective fuse (FU).","https://schema.org",{"og:url":78,"og:type":121,"og:title":59,"og:site_name":91,"og:description":61},"article",{"robots":123,"canonical":78},"index,follow",{"doc_id":125,"site_id":56},564831,1792033698,{"code":4,"msg":5,"data":128},{"doc_id":125,"user_id":129,"nickname":88,"user_avatar":60,"doc_module":9,"category_id":8,"category_name":11,"doc_title":59,"doc_description":61,"doc_content":130,"file_id":131,"file_url":132,"file_type":133,"file_size":134,"view_count":101,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":9,"language":135,"language_code":57,"site_id":56,"html_lang":57,"table_of_contents":136,"faqs":137,"seo_title":138,"seo_description":61,"update_tm":139,"read_time":4},4398046744996,"Training Note: ANSI/IEC Symbols*  \n\n| ANSI\u003Cbr>Symbol | ANSI\u003Cbr>Code | IEC 617\u003Cbr>Symbol | IEC\u003Cbr>Code | Description |\n| --- | --- | --- | --- | --- |\n|  CON |  | ~~ ~~ KM |  | Contactor contact open |\n|  CON |  |  KM |  | Contactor contact closed |\n|  CR |  | ~~ ~~ KA |  | Relay contact open |\n|  CR |  |  KA |  | Relay contact closed |\n|  TR |  |  KT |  | Timed contact, N.O.– ON-delay (TDE) |\n|  TR |  |  KT |  | Timed contact, N.C.– ON-delay (TDE) |\n|  TR |  |  KT |  | Timed contact, N.C.– OFF-delay (TDD) |\n|  TR |  |  KT |  | Timed contact, N.O.– OFF-delay (TDD) |\n| | SS | \u003Cbr>\u003Cbr>SA |  | Selector switch |\n|  PB |  |  SB |  | Pushbutton N.O. |\n|  PB |  |  SB |  | Pushbutton N.C. |\n|  PB |  |  SB |  | Pushbutton mushroom head |\n|  FL |  |  SL |  | Liquid level switch |\n|  FLS |  |   SF\u003Cbr>|  | Flow switch |\n|  PS |  |  SP |  | Pressure switch |\n|  TS |  |  ST |  | Temperature switch |\n|  LS |  |  SQ |  | Limit switch |\n| | PRS |  SQ |  | Proximity switch |\n\n\n| ANSI\u003Cbr>Symbol |  |  | ANSI\u003Cbr>Code | IEC 617\u003Cbr>Symbol |  |  |  | IEC\u003Cbr>Code |  | Description |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  LT |  |  |  |  HL\u003Cbr>|  |  |  |  |  | Indicating light |\n|  PL |  |  |  |  ~~ ~~ XS |  |  |  |  |  | Plug and socket |\n|  CR |  |  |  |  ~~ ~~ KA |  |  |  |  |  | Control relay coil |\n|  CON |  |  |  |  ~~ ~~ KM |  |  |  |  |  | Contactor coil |\n|  M |  |  |  |  ~~ ~~ KM |  |  |  |  |  | Motor starter coil |\n|  TR |  |  |  | \u003Cbr>|  |  |  | ~~ ~~ KA |  | Timer coil |\n|  |  |  |  |  | |  |  |  |  |  |\n|  ~~ ~~   SOL |  |  |  |  |  | |  |  | YV | Solenoid coil |\n|  |  |  |  |  | |  |  |  |  |  |\n|  |  |  |  |  | |  |  |  |  |  |\n| |  | CTR |  |  EC |  |  |  |  |  | Electromechanical counter |\n|  |  |  |  |  |  |  |  |  |  |  |\n| \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>CB |  |  |  | |  |  |  |  | QF | Circuit breaker |\n|   T1 |  |  |  | |  |  |  | X1\u003Cbr>XT |  | Terminals (reference)\u003Cbr>Fused terminals (reference) |\n| ~~ ~~ FU |  |  |  | |  |  |   FU |  |  | Fuse, protective |\n|  |  |  |  | |  |  |  |  |  | Mechanically-linked (force-guided) contacts |\n|  |  |  |  | \u003Cbr>\u003Cbr>E-Stop |  |  |  |  |  | Emergency Stop button (mushroom head) Positive opening operation of a switch |\n|  |  |  |  | |  |  |  |  |  | Positive opening, latching with twist to reset |\n\n*FromANSI/NFPA79 and ANSI Y32 .2/IEEE 315  \n ©2007 Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • [www.bannerengineering.com](www.bannerengineering.com) • Email: [sensors@bannerengineering.com](sensors@bannerengineering.com) MS_T8_S3_E","cbCaivLBePpbEyYE","https://ap.wps.com/l/cbCaivLBePpbEyYE","pdf",175470,"English","# ANSI/IEC Symbol Reference Tables\n## Contact Elements and Switches\n## Coils, Counters, Protection Devices, and Terminals","[{\"question\":\"What do the tables provide for each symbol?\",\"answer\":\"Each entry lists an ANSI symbol and ANSI code, then aligns it with the IEC 617 symbol and IEC code, followed by a short description.\"},{\"question\":\"Which timed contact types are referenced?\",\"answer\":\"The note includes timed contact open/closed variants for ON-delay (TDE) and OFF-delay (TDD), labeled for both normally open and normally closed behavior.\"},{\"question\":\"Does the reference include emergency stop and protection devices?\",\"answer\":\"Yes. It includes an emergency stop button (mushroom head) description and references protection devices such as circuit breaker (QF) and fuse/protective fuse (FU).\"}]","ANSI/IEC Symbols - Training Note | PDF",1791844450]