[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-pt-112":3,"doc-seo-190341-112":41,"doc-detail-190341-pt":115},{"code":4,"msg":5,"data":6},0,"success",[7,13,17,21,25,29,33,37],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":4,"slug":12},167,1,"Template","Apresentações","apresentacoes",{"id":14,"doc_module":9,"doc_module_name":10,"category_name":15,"show_sort_weight":4,"slug":16},174,"Cartas","cartas",{"id":18,"doc_module":9,"doc_module_name":10,"category_name":19,"show_sort_weight":4,"slug":20},171,"Cartazes","cartazes",{"id":22,"doc_module":9,"doc_module_name":10,"category_name":23,"show_sort_weight":4,"slug":24},168,"Currículos","curriculos",{"id":26,"doc_module":9,"doc_module_name":10,"category_name":27,"show_sort_weight":4,"slug":28},170,"Faturas","faturas",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":4,"slug":32},173,"Formulários","formularios",{"id":34,"doc_module":9,"doc_module_name":10,"category_name":35,"show_sort_weight":4,"slug":36},175,"Geral","geral-25299031d61e408a910febceb3238a26",{"id":38,"doc_module":9,"doc_module_name":10,"category_name":39,"show_sort_weight":4,"slug":40},172,"Redes sociais","redes-sociais",{"code":4,"msg":42,"data":43},"ok",{"site_id":44,"language":45,"slug":46,"title":47,"keywords":48,"description":49,"schema_data":50,"social_meta":108,"head_meta":110,"extra_data":112,"updated_unix":114},112,"pt","tfp620_12_2011_pt","TFP620_12_2011_PT","","Detalhamento técnico para sprinklers de janela do modelo WS, incluindo identificação de componentes, dimensões e elementos geométricos relacionados à instalação em janelas não operáveis. O material descreve critérios de aplicação em situações com ou sem redes de sprinklers, condições vinculadas a separações de incêndio interna e externa e orientação de posicionamento dos sprinklers conforme o lado de exposição. Também apresenta referências visuais (figuras) e regras de espaçamento mínimo entre dispositivos, com menção a defletores e barras divisórias quando aplicável.",{"@graph":51,"@context":107},[52,68,90],{"@type":53,"itemListElement":54},"BreadcrumbList",[55,59,62,65],{"item":56,"name":57,"@type":58,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":60,"name":10,"@type":58,"position":61},"https://docshare.wps.com/pt/template/",2,{"item":63,"name":35,"@type":58,"position":64},"https://docshare.wps.com/pt/template/geral/",3,{"item":66,"name":47,"@type":58,"position":67},"https://docshare.wps.com/pt/template/tfp620_12_2011_pt/190341/",4,{"url":66,"name":47,"@type":69,"image":70,"author":75,"headline":47,"publisher":78,"fileFormat":81,"inLanguage":45,"description":49,"dateModified":82,"datePublished":83,"encodingFormat":81,"isAccessibleForFree":84,"interactionStatistic":85},"DigitalDocument",{"url":71,"@type":72,"width":73,"height":74},"https://docshare.wps.com/thumbnails/tfp620_12_2011_pt/190341.png","ImageObject",442,249,{"name":76,"@type":77},"Aurelia","Person",{"url":56,"name":79,"@type":80},"DocShare","Organization","application/pdf","2026-10-06","2026-09-03",true,{"@type":86,"interactionType":87,"userInteractionCount":89},"InteractionCounter",{"@type":88},"ViewAction",7,{"@type":91,"mainEntity":92},"FAQPage",[93,99,103],{"name":94,"@type":95,"acceptedAnswer":96},"Quais são os componentes principais de um sprinkler de janela modelo WS?","Question",{"text":97,"@type":98},"O documento lista componentes como corpo, obturador, conjunto de vedação e itens associados ao conjunto, incluindo ampola, parafuso de descompressão e defletor (com referência à temperatura nominal no defletor).","Answer",{"name":100,"@type":95,"acceptedAnswer":101},"Quando os sprinklers de janela modelo WS podem ser usados para proteger aberturas de janela não operáveis?",{"text":102,"@type":98},"Quando aceitável pela autoridade competente, podem ser usados em edificações com ou sem rede de sprinklers para proteger janelas não operáveis que façam parte de uma separação de incêndio, respeitando a configuração do lado de instalação conforme o caso.",{"name":104,"@type":95,"acceptedAnswer":105},"Qual é a regra para o espaçamento mínimo entre sprinklers de janela?",{"text":106,"@type":98},"A distância mínima informada entre os sprinklers de janela é de 1,83 m, podendo ser alterada apenas quando houver separação por defletor ou barra divisória com profundidade suficiente para atuar como defletor.","https://schema.org",{"og:url":66,"og:type":109,"og:title":47,"og:site_name":79,"og:description":49},"article",{"robots":111,"canonical":66},"index,follow",{"doc_id":113,"site_id":44},190341,1790717653,{"code":4,"msg":5,"data":116},{"doc_id":113,"user_id":117,"nickname":76,"user_avatar":118,"doc_module":9,"category_id":34,"category_name":35,"doc_title":47,"doc_description":49,"doc_content":119,"file_id":120,"file_url":121,"file_type":122,"file_size":123,"view_count":89,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":124,"language":125,"language_code":45,"site_id":44,"html_lang":45,"table_of_contents":126,"faqs":127,"seo_title":128,"seo_description":49,"update_tm":129,"read_time":64},1099514068365,"https://ap-avatar.wpscdn.com/avatar/10000253d8d9f28188e?_k=1776742907772140068","| Serviços Técnicos:\u003Cbr>| 800-381-9312 +1-401-781-8220 [www.tyco-fire.com](www.tyco-fire.com) |\n| --- | --- |\n\n| Componentes:\u003Cbr>• Corpo\u003Cbr>• Obturador\u003Cbr>• Conjunto de vedação | • Ampola\u003Cbr>• Parafuso decompressão\u003Cbr>• Defletor* | * A temperatura nominal de operação é indicada no Defletor. | NPT\u003Cbr>1/2” | ROSCA ÚTIL 1 1,1 mm (7/16”) |\n| --- | --- | --- | --- | --- |\n| 3\u003Cbr>5/8\"\u003Cbr>(15,9 mm)\u003Cbr>5\u003Cbr>4\u003Cbr>\u003Cbr>2\u003Cbr>1\u003Cbr>2-1/16\"(52,4 mm)\u003Cbr>2-1/8\"(54,0 mm)\u003Cbr>\u003Cbr>LINHA CENTRAL DO CIRCUITODE ÁGUA DO SPRINKLER\u003Cbr>\u003Cbr>DIRECIONE ASETA DE VAZÃO (INDICADA NODEFLETOR) PARA A JANELA\u003Cbr>\u003Cbr>\u003Cbr>TOPO DO DEFLETORDO SPRINKLER\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>SUPERFÍCIES DE APERTO\u003Cbr>BRAÇOS DEARMAÇÃODO SPRINKLER\u003Cbr>SEÇÃO TRANSVERSAL VOLTADO PARA A ELEVAÇÃO\u003Cbr>DA JANELA\u003Cbr>FIGURA 2\u003Cbr>SPRINKLER DE JANELA MODELO WSPAREDE VERTICAL SUSPENSA |  |  |  |  |\n\n\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | Quando aceitável pela autoridade competente, os Sprinklers de Janela de Aplicação Específica Modelo WS poderão ser usados em edificações com ou sem redes de sprinklers para protegeraberturas de janela não operáveis em separação de incêndio interna, com os sprinklers de janela instalados em ambos os lados da janela na separação de incêndio.\u003Cbr>\u003Cbr>DENTRO\u003Cbr>|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| DENTRO\u003Cbr>FIGURA 3A-1-SEPARAÇÃO INTERNA CONTRA INCÊNDIO\u003Cbr>\u003Cbr>Quando aceitável pela autoridade competente, os Sprinklers de Janela com Aplicação Modelo WS podem ser usados em edificação com ou sem rede de sprinklers para proteger aberturas de janelanão operáveis que sejam parte de uma separação de incêndio, desde que em jurisdições ondea separação espacial externa seja definida como proteção de uma edificação adjacente contra o incêndio em sua própria edificação, com sprinklers de janela instalados no lado interno do vidro.\u003Cbr>FORA |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  | \u003Cbr>LADO DE EXPOSIÇÃO\u003Cbr>\u003Cbr>DENTRO\u003Cbr>FIGURA 3A-2--SEPARAÇÃO DE INCÊNDIO EXTERNA\u003Cbr>SPRINKLERS NO INTERIOR |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | \u003Cbr>- |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Quando aceitável pela autoridade competente, os Sprinklers de Janela com Aplicação Modelo WS podem ser usados em edificação com ou sem rede de sprinklers para proteger aberturas dejanela não operáveis que sejam parte de uma separação de incêndio, desde que em jurisdiçõesonde a separação espacial externa seja definida como proteção de sua própria edificação contra o incêndio em edificação adjacente, com sprinklers de janela aberta instalados no lado interno dovidro.\u003Cbr>DENTRO |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  | \u003Cbr>LADO DE EXPOSIÇÃO\u003Cbr>\u003Cbr>FORA\u003Cbr>FIGURA 3A-3--SEPARAÇÃO DE INCÊNDIO EXTERNA\u003Cbr>SPRINKLERS NO EXTERIOR |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | \u003Cbr>- |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  ","cbCainms8CbqEM90","https://ap.wps.com/l/cbCainms8CbqEM90","pdf",442236,8,"Portuguese","# Componentes e identificação\n## Dimensões e marcações\n# Aplicações em separações de incêndio\n## Separação interna\n## Separação externa\n# Figuras e critérios de instalação","[{\"question\":\"Quais são os componentes principais de um sprinkler de janela modelo WS?\",\"answer\":\"O documento lista componentes como corpo, obturador, conjunto de vedação e itens associados ao conjunto, incluindo ampola, parafuso de descompressão e defletor (com referência à temperatura nominal no defletor).\"},{\"question\":\"Quando os sprinklers de janela modelo WS podem ser usados para proteger aberturas de janela não operáveis?\",\"answer\":\"Quando aceitável pela autoridade competente, podem ser usados em edificações com ou sem rede de sprinklers para proteger janelas não operáveis que façam parte de uma separação de incêndio, respeitando a configuração do lado de instalação conforme o caso.\"},{\"question\":\"Qual é a regra para o espaçamento mínimo entre sprinklers de janela?\",\"answer\":\"A distância mínima informada entre os sprinklers de janela é de 1,83 m, podendo ser alterada apenas quando houver separação por defletor ou barra divisória com profundidade suficiente para atuar como defletor.\"}]","TFP620_12_2011_PT | PDF",1788402092]