[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-1-fr-114":3,"doc-seo-205037-114":41,"doc-detail-205037-fr":114},{"code":4,"msg":5,"data":6},0,"success",[7,13,17,21,25,29,33,37],{"id":8,"doc_module":9,"doc_module_name":10,"category_name":11,"show_sort_weight":4,"slug":12},187,1,"Template","Affiches","affiches",{"id":14,"doc_module":9,"doc_module_name":10,"category_name":15,"show_sort_weight":4,"slug":16},185,"CV","cv-de4d58cbecd644d0a7e318765621a3e1",{"id":18,"doc_module":9,"doc_module_name":10,"category_name":19,"show_sort_weight":4,"slug":20},186,"Factures","factures",{"id":22,"doc_module":9,"doc_module_name":10,"category_name":23,"show_sort_weight":4,"slug":24},189,"Formulaires","formulaires",{"id":26,"doc_module":9,"doc_module_name":10,"category_name":27,"show_sort_weight":4,"slug":28},191,"Général","general-191",{"id":30,"doc_module":9,"doc_module_name":10,"category_name":31,"show_sort_weight":4,"slug":32},190,"Lettres","lettres",{"id":34,"doc_module":9,"doc_module_name":10,"category_name":35,"show_sort_weight":4,"slug":36},184,"Présentations","cv-767d690125b54e1a9d6afd8b391bba13",{"id":38,"doc_module":9,"doc_module_name":10,"category_name":39,"show_sort_weight":4,"slug":40},188,"Réseaux sociaux","reseaux-sociaux",{"code":4,"msg":42,"data":43},"ok",{"site_id":44,"language":45,"slug":46,"title":47,"keywords":48,"description":49,"schema_data":50,"social_meta":107,"head_meta":109,"extra_data":111,"updated_unix":113},114,"fr","thermostatic-expansion-valves-installers-guide","Détendeurs thermostatiques - Guide du monteur","","Guide du monteur sur les détendeurs thermostatiques utilisés en réfrigération et climatisation. Présente le principe de fonctionnement basé sur l’équilibre des pressions du bulbe, de l’évaporation et du ressort, ainsi que les notions de surchauffe, de sous-refroidissement et d’égalisation de pression externe. Explique les différents types de charges (universelle, MOP, MOP ballast), leurs conditions d’application, la logique de limitation de pression au démarrage, et les effets sur la régulation de l’injection de liquide vers l’évaporateur.",{"@graph":51,"@context":106},[52,68,89],{"@type":53,"itemListElement":54},"BreadcrumbList",[55,59,62,65],{"item":56,"name":57,"@type":58,"position":9},"https://docshare.wps.com","Home","ListItem",{"item":60,"name":10,"@type":58,"position":61},"https://docshare.wps.com/fr/template/",2,{"item":63,"name":35,"@type":58,"position":64},"https://docshare.wps.com/fr/template/présentations/",3,{"item":66,"name":47,"@type":58,"position":67},"https://docshare.wps.com/fr/template/thermostatic-expansion-valves-installers-guide/205037/",4,{"url":66,"name":47,"@type":69,"image":70,"author":75,"headline":47,"publisher":78,"fileFormat":81,"inLanguage":45,"description":49,"dateModified":82,"datePublished":83,"encodingFormat":81,"isAccessibleForFree":84,"interactionStatistic":85},"DigitalDocument",{"url":71,"@type":72,"width":73,"height":74},"https://docshare.wps.com/thumbnails/thermostatic-expansion-valves-installers-guide/205037.png","ImageObject",442,249,{"name":76,"@type":77},"Finn","Person",{"url":56,"name":79,"@type":80},"DocShare","Organization","application/pdf","2026-09-18","2026-09-05",true,{"@type":86,"interactionType":87,"userInteractionCount":9},"InteractionCounter",{"@type":88},"ViewAction",{"@type":90,"mainEntity":91},"FAQPage",[92,98,102],{"name":93,"@type":94,"acceptedAnswer":95},"Comment fonctionne un détendeur thermostatique ?","Question",{"text":96,"@type":97},"Le détendeur maintient l’équilibre entre la pression du bulbe, la pression d’évaporation et la pression du ressort sur la membrane. Le ressort sert au réglage de la surchauffe.","Answer",{"name":99,"@type":94,"acceptedAnswer":100},"Qu’est-ce que la surchauffe dans ce contexte ?",{"text":101,"@type":97},"La surchauffe se mesure au point d’installation du bulbe sur la conduite d’aspiration. Elle correspond à la différence entre la température au voisinage du bulbe et la pression (ou température) d’évaporation au même point.",{"name":103,"@type":94,"acceptedAnswer":104},"Quelle différence existe entre les charges universelles, MOP et MOP ballast ?",{"text":105,"@type":97},"La charge universelle n’impose pas de limitation de pression et évite le risque de migration du fluide. La charge MOP limite la pression maximale admissible : au-dessus du point MOP, la charge s’est évaporée. La charge MOP ballast est conçue pour des évaporateurs à haute dynamique et permet une surchauffe plus basse, de 2 à 4 K.","https://schema.org",{"og:url":66,"og:type":108,"og:title":47,"og:site_name":79,"og:description":49},"article",{"robots":110,"canonical":66},"index,follow",{"doc_id":112,"site_id":44},205037,1788577244,{"code":4,"msg":5,"data":115},{"doc_id":112,"user_id":116,"nickname":76,"user_avatar":117,"doc_module":9,"category_id":34,"category_name":35,"doc_title":47,"doc_description":49,"doc_content":118,"file_id":119,"file_url":120,"file_type":121,"file_size":122,"view_count":9,"is_deleted":4,"is_public":9,"is_downloadable":9,"audit_status":9,"page_count":123,"language":124,"language_code":45,"site_id":44,"html_lang":45,"table_of_contents":125,"faqs":126,"seo_title":127,"seo_description":49,"update_tm":113,"read_time":128},34359740700684,"https://ap-avatar.wpscdn.com/avatar/1f400023980c374ae676?_k=1777273430885731487","Refrigeration and Air Conditioning Controls  \nGuide du monteur  \nDétendeurs thermostatiques  \nR E F R I G E R A T I O N A N D A I R C O N D I T I O N I N G  \nGuide du monteur  \nDétendeurs thermostatiques  \nContenu Page  \nPrincipe du détendeur thermostatique ............................................................................. 3  \nCharges ............................................................................................................................ 5  \nSélection du détendeur thermostatique............................................................................ 7  \nIdentiﬁcation ..................................................................................................................... 7  \nMontage............................................................................................................................ 9  \nRéglage .......................................................................................................................... 12  \nDépannage ..................................................................................................................... 14  \nGamme des produits Danfoss ........................................................................................ 18  \nGuide du monteur Détendeurs thermostatiques  \nUn détendeur thermostatique est constitué d’un élément thermostatique (1) séparé du corps de vanne par une membrane. Un tube capillaire relie l’élément thermostatique à un bulbe (2), un corps de vanne avec un siège (3) et un ressort (4) .  \nPrincipe du détendeur thermostatique  \nSon fonctionnement dépend de 3 pressions fondamentales:  \nP1: pression du bulbe exercée sur la facesupérieure de la membrane (ouverture du détendeur),  \nP2: pression d’évaporation exercée sur la face inférieure de la membrane (fermeture du détendeur)  \nP3: pression du ressort exercée elle aussi sur la face inférieure de la membrane (fermeture du détendeur) .  \nLa régulation assurée par le détendeur esten fait le maintien de l’équilibre entre la pression du bulbe, d’un côté de la membrane, et la pression d’évaporation plus la pression du ressort du côté opposé . Le ressort permet le réglage de la surchauffe.  \nAd0-0001  \nGuide du monteur Détendeurs thermostatiques  \nSurchauffe  \nLa surchauffe se mesure au point d’installation du bulbe sur la conduited’aspiration ; elle est égale à la différence entre la température près du bulbe et la pression (ou la température) d’évaporation au même point.  \nLa surchauffe, qui s’exprime en Kelvin (K) sert de signal pour la régulation del’injection de liquide par le détendeur.  \nSous-refroidissement  \nLe sous-refroidissement se déﬁnit comme la différence entre la température du ﬂuidefrigorigène liquide et la pression (ou température) de condensation, à l’entréedu détendeur. Le sous-refroidissements’exprime en Kelvin (K) . Il est nécessaireaﬁn éviter les bulles de vapeur dans le liquide, à l’entrée du détendeur. Les bulles de vapeur réduisent la capacité dudétendeur et gênent l’alimentation en liquide de l’évaporateur. Un sousrefroidissement de 4 à 5 K sufﬁt dans la plupart des cas.  \nEgalisation de pression externe  \nIl faut toujours utiliser les détendeurs àégalisation de pression externe dans les installations à distributeur de liquide. Généralement, la perte de charge dans le distributeur et les capillaires du distributeurest de 1 bar.  \nLes détendeurs à égalisation de pressionexterne sont recommandés pour les installations à petits évaporateurs compacts (échangeurs de chaleur à plaques, par exemple) où la perte de charge dépasse souvent la pression correspondant à 2 K.  \nAd0-0012  \nAd0-0015  \nGuide du monteur Détendeurs thermostatiques  \nCharges  \nTrois types de charges existent sur les détendeurs thermostatiques, à savoir:  \n1. charge universelle,  \n2. charge MOP,  \n3. charge MOP ballast (norme pour ledétendeur Danfoss avec MOP) .  \nLes détendeurs à charge universelle sont fréquents dans les installations frigoriﬁquesoù la limitation de","cbCaitSId1SzzGmw","https://ap.wps.com/l/cbCaitSId1SzzGmw","pdf",1256390,20,"French","# Principe du détendeur thermostatique\n## Surchauffe\n## Sous-refroidissement\n## Égalisation de pression externe\n# Charges\n## Charge universelle\n## Charge MOP\n## Charge MOP ballast","[{\"question\":\"Comment fonctionne un détendeur thermostatique ?\",\"answer\":\"Le détendeur maintient l’équilibre entre la pression du bulbe, la pression d’évaporation et la pression du ressort sur la membrane. Le ressort sert au réglage de la surchauffe.\"},{\"question\":\"Qu’est-ce que la surchauffe dans ce contexte ?\",\"answer\":\"La surchauffe se mesure au point d’installation du bulbe sur la conduite d’aspiration. Elle correspond à la différence entre la température au voisinage du bulbe et la pression (ou température) d’évaporation au même point.\"},{\"question\":\"Quelle différence existe entre les charges universelles, MOP et MOP ballast ?\",\"answer\":\"La charge universelle n’impose pas de limitation de pression et évite le risque de migration du fluide. La charge MOP limite la pression maximale admissible : au-dessus du point MOP, la charge s’est évaporée. La charge MOP ballast est conçue pour des évaporateurs à haute dynamique et permet une surchauffe plus basse, de 2 à 4 K.\"}]","Détendeurs thermostatiques - Guide du monteur | PDF",7]