[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-es-110":3,"doc-seo-366466-110":49,"doc-detail-366466-es":124},{"code":4,"msg":5,"data":6},0,"success",[7,13,17,21,25,29,33,37,41,45],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},39,"Document","Cómic",60,"comic",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":11,"slug":16},43,"Estilo de Vida","lifestyle",{"id":18,"doc_module":4,"doc_module_name":9,"category_name":19,"show_sort_weight":11,"slug":20},38,"Examen","exam",{"id":22,"doc_module":4,"doc_module_name":9,"category_name":23,"show_sort_weight":11,"slug":24},44,"General","general",{"id":26,"doc_module":4,"doc_module_name":9,"category_name":27,"show_sort_weight":11,"slug":28},41,"Investigación e Informes","research-report",{"id":30,"doc_module":4,"doc_module_name":9,"category_name":31,"show_sort_weight":11,"slug":32},37,"Literatura","literature",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":11,"slug":36},22,"Relatos y Novelas","story-novel",{"id":38,"doc_module":4,"doc_module_name":9,"category_name":39,"show_sort_weight":11,"slug":40},42,"Religión y Espiritualidad","religion-spirituality",{"id":42,"doc_module":4,"doc_module_name":9,"category_name":43,"show_sort_weight":11,"slug":44},40,"Salud y Atención Médica","healthcare",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":47,"show_sort_weight":11,"slug":48},24,"Tecnología","technology",{"code":4,"msg":50,"data":51},"ok",{"site_id":52,"language":53,"slug":54,"title":55,"keywords":56,"description":57,"schema_data":58,"social_meta":117,"head_meta":119,"extra_data":121,"updated_unix":123},110,"es","tables-annex-of-nom-001-sede-2012-tables-250-122-310-15b16-and-310-15b17","ANEXO DE TABLAS DE LA NOM-001-SEDE - 2012 - Tablas 250-122, 310-15(b)(16) y 310-15(b)(17)","","Anexo de tablas de la NOM-001-SEDE-2012 que presenta equivalencias y criterios para dimensionar conductores en sistemas eléctricos. Incluye la Tabla 250-122 con el tamaño mínimo del conductor de puesta a tierra para canalizaciones y equipos, con valores en cobre y en aluminio o cobre recubierto. También reúne las Tablas 310-15(b)(16) y 310-15(b)(17) con ampacidades permisibles de conductores aislados, para tensiones hasta 2000 V e instalaciones al aire libre, considerando temperaturas nominales y hasta tres conductores en canalización.",{"@graph":59,"@context":116},[60,77,99],{"@type":61,"itemListElement":62},"BreadcrumbList",[63,68,71,74],{"item":64,"name":65,"@type":66,"position":67},"https://docshare.wps.com","Home","ListItem",1,{"item":69,"name":9,"@type":66,"position":70},"https://docshare.wps.com/es/document/",2,{"item":72,"name":27,"@type":66,"position":73},"https://docshare.wps.com/es/document/investigación-e-informes/",3,{"item":75,"name":55,"@type":66,"position":76},"https://docshare.wps.com/es/document/tables-annex-of-nom-001-sede-2012-tables-250-122-310-15b16-and-310-15b17/366466/",4,{"url":75,"name":55,"@type":78,"image":79,"author":84,"headline":55,"publisher":87,"fileFormat":90,"inLanguage":53,"description":57,"dateModified":91,"datePublished":92,"encodingFormat":90,"isAccessibleForFree":93,"interactionStatistic":94},"DigitalDocument",{"url":80,"@type":81,"width":82,"height":83},"https://docshare.wps.com/thumbnails/tables-annex-of-nom-001-sede-2012-tables-250-122-310-15b16-and-310-15b17/366466.png","ImageObject",300,407,{"name":85,"@type":86},"\tJames","Person",{"url":64,"name":88,"@type":89},"DocShare","Organization","application/pdf","2026-10-07","2026-09-23",true,{"@type":95,"interactionType":96,"userInteractionCount":98},"InteractionCounter",{"@type":97},"ViewAction",5,{"@type":100,"mainEntity":101},"FAQPage",[102,108,112],{"name":103,"@type":104,"acceptedAnswer":105},"Qué información ofrece la Tabla 250-122 en el anexo?","Question",{"text":106,"@type":107},"Define el tamaño mínimo del conductor de puesta a tierra para canalizaciones y equipos, con valores para cobre y para aluminio o aluminio recubierto de cobre, sin exceder los amperes indicados.","Answer",{"name":109,"@type":104,"acceptedAnswer":110},"Qué condiciones de temperatura y tensión consideran las Tablas 310-15(b)(16) y 310-15(b)(17)?",{"text":111,"@type":107},"Presentan ampacidades permisibles de conductores aislados para tensiones hasta 2000 volts, considerando temperaturas nominales del conductor (60 °C, 75 °C y 90 °C) y una temperatura ambiente de 30 °C.",{"name":113,"@type":104,"acceptedAnswer":114},"Cuándo aplicar los factores de corrección de ampacidad indicados en el anexo?",{"text":115,"@type":107},"Cuando la temperatura ambiente difiera de 30 °C, el texto remite a 310-15(b)(2) para los factores de corrección de la ampacidad.","https://schema.org",{"og:url":75,"og:type":118,"og:title":55,"og:site_name":88,"og:description":57},"article",{"robots":120,"canonical":75},"index,follow",{"doc_id":122,"site_id":52},366466,1790693037,{"code":4,"msg":5,"data":125},{"doc_id":122,"user_id":126,"nickname":85,"user_avatar":127,"doc_module":4,"category_id":26,"category_name":27,"doc_title":55,"doc_description":57,"doc_content":128,"file_id":129,"file_url":130,"file_type":131,"file_size":132,"view_count":98,"is_deleted":4,"is_public":67,"is_downloadable":67,"audit_status":67,"page_count":133,"language":134,"language_code":53,"site_id":52,"html_lang":53,"table_of_contents":135,"faqs":136,"seo_title":137,"seo_description":57,"update_tm":138,"read_time":139},2336474466412,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","5. 9 ANEXO DE TABLAS DE LA NOM-001-SEDE–2012  \nTabla 250-122.-Tamaño mínimo de los conductores de puesta a tierra para canalizaciones y  \nequipos  \n\n| Capacidad o ajuste\u003Cbr>del dispositivo\u003Cbr>automático de\u003Cbr>protección contra sobrecorriente en el circuito antes de losequipos, canalizaciones, etc., sin exceder de:(amperes) | Tamaño |  |  |  |\n| --- | --- | --- | --- | --- |\n|  | Cobre |  | Cable de aluminioo aluminio con cobre |  |\n|  | mm2 | AWG o\u003Cbr>kcmil | mm2 | AWG o\u003Cbr>kcmil |\n| 15 | 2.08 | 14 | — | — |\n| 20 | 3.31 | 12 | — | — |\n| 60 | 5.26 | 10 | — | — |\n| 100 | 8.37 | 8 | — | — |\n| 200 | 13.30 | 6 | 21.20 | 4 |\n| 300 | 21.20 | 4 | 33.60 | 2 |\n| 400 | 33.60 | 2 | 42.40 | 1 |\n| 500 | 33.60 | 2 | 53.50 | 1/0 |\n| 600 | 42.40 | 1 | 67.40 | 2/0 |\n| 800 | 53.50 | 1/0 | 85.00 | 3/0 |\n| 1000 | 67.40 | 2/0 | 107 | 4/0 |\n| 1200 | 85.00 | 3/0 | 127 | 250 |\n| 1600 | 107 | 4/0 | 177 | 350 |\n| 2000 | 127 | 250 | 203 | 400 |\n| 2500 | 177 | 350 | 304 | 600 |\n| 3000 | 203 | 400 | 304 | 600 |\n| 4000 | 253 | 500 | 380 | 750 |\n| 5000 | 355 | 700 | 608 | 1200 |\n| 6000 | 405 | 800 | 608 | 1200 |\n\nPara cumplir con lo establecido en 250-4(a)(5) o (b)(4), el conductor de puesta a tierra de equipos podría ser de mayor tamaño que lo especificado  \nen esta Tabla.  \n*Véase 250-120 para restricciones de instalación.  \nTabla 310-15(b)(16) .- La tabla de la siguiente página, nos muestra las Ampacidades permisibles en conductores aislados para tensiones hasta 2000 volts y 60 °C a 90 °C. No más de tres conductores  \nportadores de corriente en una canalización, cable o directamente enterrados, basados en una temperatura ambiente de 30 °C*  \n\n| Tamaño\u003Cbr>o\u003Cbr>designación |  | Temperatura nominal del conductor [Véase la tabla 310-104(a)] |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  | 60 °C | 75 °C | 90 °C | 60 °C | 75 °C | 90 °C |\n| mm2 | AWG o\u003Cbr>kcmil | TIPOS\u003Cbr>TW, UF | TIPOS\u003Cbr>RHW,\u003Cbr>THHW,\u003Cbr>THHW-LS,\u003Cbr>THW,\u003Cbr>THW-LS,\u003Cbr>THWN,\u003Cbr>XHHW,\u003Cbr>USE, ZW | TIPOS\u003Cbr>TBS, SA,\u003Cbr>SIS, FEP,\u003Cbr>FEPB, MI,\u003Cbr>RHH,\u003Cbr>RHW-2,\u003Cbr>THHN,\u003Cbr>THHW,\u003Cbr>THHW-LS,\u003Cbr>THW-2,\u003Cbr>THWN-2,\u003Cbr>USE-2,\u003Cbr>XHH,\u003Cbr>XHHW,\u003Cbr>XHHW-2,\u003Cbr>ZW-2 | TIPOS\u003Cbr>UF | TIPOS\u003Cbr>RHW, XHHW,\u003Cbr>USE | TIPOS\u003Cbr>SA, SIS,\u003Cbr>RHH, RHW-\u003Cbr>2, USE-2,\u003Cbr>XHH, XHHW,\u003Cbr>XHHW-2,\u003Cbr>ZW-2 |\n|  |  | COBRE |  |  | ALUMINIO O ALUMINIO RECUBIERTODE COBRE |  |  |\n| 0.824\u003Cbr>1.31\u003Cbr>2.08\u003Cbr>3.31\u003Cbr>5.26\u003Cbr>8.37 | 18**\u003Cbr>16**\u003Cbr>14**\u003Cbr>12**\u003Cbr>10**\u003Cbr>8 | —\u003Cbr>—\u003Cbr>15\u003Cbr>20\u003Cbr>30\u003Cbr>40 | —\u003Cbr>—\u003Cbr>20\u003Cbr>25\u003Cbr>35\u003Cbr>50 | 14\u003Cbr>18\u003Cbr>25\u003Cbr>30\u003Cbr>40\u003Cbr>55 | —\u003Cbr>—\u003Cbr>—\u003Cbr>—\u003Cbr>—\u003Cbr>— | —\u003Cbr>—\u003Cbr>—\u003Cbr>—\u003Cbr>—\u003Cbr>— | —\u003Cbr>—\u003Cbr>—\u003Cbr>—\u003Cbr>—\u003Cbr>— |\n| 13.3\u003Cbr>21.2\u003Cbr>26.7\u003Cbr>33.6\u003Cbr>42.4 | 6\u003Cbr>4 3\u003Cbr>2\u003Cbr>1 | 55\u003Cbr>70\u003Cbr>85\u003Cbr>95\u003Cbr>110 | 65\u003Cbr>85\u003Cbr>100\u003Cbr>115\u003Cbr>130 | 75\u003Cbr>95\u003Cbr>115\u003Cbr>130\u003Cbr>145 | 40\u003Cbr>55\u003Cbr>65\u003Cbr>75\u003Cbr>85 | 50\u003Cbr>65\u003Cbr>75\u003Cbr>90\u003Cbr>100 | 55\u003Cbr>75\u003Cbr>85\u003Cbr>100\u003Cbr>115 |\n| 53.49\u003Cbr>67.43\u003Cbr>85.01\u003Cbr>107.2 | 1/0\u003Cbr>2/0\u003Cbr>3/0\u003Cbr>4/0 | 125\u003Cbr>145\u003Cbr>165\u003Cbr>195 | 150\u003Cbr>175\u003Cbr>200\u003Cbr>230 | 170\u003Cbr>195\u003Cbr>225\u003Cbr>260 | 100\u003Cbr>115\u003Cbr>130\u003Cbr>150 | 120\u003Cbr>135\u003Cbr>155\u003Cbr>180 | 135\u003Cbr>150\u003Cbr>175\u003Cbr>205 |\n| 127\u003Cbr>152\u003Cbr>177\u003Cbr>203\u003Cbr>253 | 250\u003Cbr>300\u003Cbr>350\u003Cbr>400\u003Cbr>500 | 215\u003Cbr>240\u003Cbr>260\u003Cbr>280\u003Cbr>320 | 255\u003Cbr>285\u003Cbr>310\u003Cbr>335\u003Cbr>380 | 290\u003Cbr>320\u003Cbr>350\u003Cbr>380\u003Cbr>430 | 170\u003Cbr>195\u003Cbr>210\u003Cbr>225\u003Cbr>260 | 205\u003Cbr>230\u003Cbr>250\u003Cbr>270\u003Cbr>310 | 230\u003Cbr>260\u003Cbr>280\u003Cbr>305\u003Cbr>350 |\n| 304\u003Cbr>355\u003Cbr>380\u003Cbr>405\u003Cbr>456 | 600\u003Cbr>700\u003Cbr>750\u003Cbr>800\u003Cbr>900 | 350\u003Cbr>385\u003Cbr>400\u003Cbr>410\u003Cbr>435 | 420\u003Cbr>460\u003Cbr>475\u003Cbr>490\u003Cbr>520 | 475\u003Cbr>520\u003Cbr>535\u003Cbr>555\u003Cbr>585 | 285\u003Cbr>315\u003Cbr>320\u003Cbr>330\u003Cbr>355 | 340\u003Cbr>375\u003Cbr>385\u003Cbr>395\u003Cbr>425 | 385\u003Cbr>425\u003Cbr>435\u003Cbr>445\u003Cbr>480 |\n| 507\u003Cbr>633\u003Cbr>760\u003Cbr>887\u003Cbr>1013 | 1000\u003Cbr>1250\u003Cbr>1500\u003Cbr>1750\u003Cbr>2000 | 455\u003Cbr>495\u003Cbr>525\u003Cbr>545\u003Cbr>555 | 545\u003Cbr>590\u003Cbr>625\u003Cbr>650\u003Cbr>665 | 615\u003Cbr>665\u003Cbr>705\u003Cbr>735\u003Cbr>750 | 375\u003Cbr>405\u003Cbr>435\u003Cbr>455\u003Cbr>470 | 445\u003Cbr>485\u003Cbr>520\u003Cbr>545\u003Cbr>560 | 500\u003Cbr>545\u003Cbr>585\u003Cbr>615\u003Cbr>630 |\n\n* Véase 310-15(b)(2) para los factores de corrección de la ampacidad cuando ","cbCaia2Xy4DYqa9t","https://ap.wps.com/l/cbCaia2Xy4DYqa9t","pdf",1122299,17,"Spanish","# Tabla 250-122\n## Tamaño mínimo de conductores de puesta a tierra\n# Tabla 310-15(b)(16)\n## Ampacidades en conductores aislados (hasta 2000 V, 60 °C a 90 °C)\n# Tabla 310-15(b)(17)\n## Ampacidades para conductores individuales aislados al aire libre","[{\"question\":\"Qué información ofrece la Tabla 250-122 en el anexo?\",\"answer\":\"Define el tamaño mínimo del conductor de puesta a tierra para canalizaciones y equipos, con valores para cobre y para aluminio o aluminio recubierto de cobre, sin exceder los amperes indicados.\"},{\"question\":\"Qué condiciones de temperatura y tensión consideran las Tablas 310-15(b)(16) y 310-15(b)(17)?\",\"answer\":\"Presentan ampacidades permisibles de conductores aislados para tensiones hasta 2000 volts, considerando temperaturas nominales del conductor (60 °C, 75 °C y 90 °C) y una temperatura ambiente de 30 °C.\"},{\"question\":\"Cuándo aplicar los factores de corrección de ampacidad indicados en el anexo?\",\"answer\":\"Cuando la temperatura ambiente difiera de 30 °C, el texto remite a 310-15(b)(2) para los factores de corrección de la ampacidad.\"}]","ANEXO DE TABLAS DE LA NOM-001-SEDE - 2012 - Tablas 250-122, 310-15(b)(16) y 310-15(b)(17) | PDF",1790165689,26]