[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-es-110":3,"doc-seo-366479-110":49,"doc-detail-366479-es":123},{"code":4,"msg":5,"data":6},0,"success",[7,13,17,21,25,29,33,37,41,45],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},39,"Document","Cómic",60,"comic",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":11,"slug":16},43,"Estilo de Vida","lifestyle",{"id":18,"doc_module":4,"doc_module_name":9,"category_name":19,"show_sort_weight":11,"slug":20},38,"Examen","exam",{"id":22,"doc_module":4,"doc_module_name":9,"category_name":23,"show_sort_weight":11,"slug":24},44,"General","general",{"id":26,"doc_module":4,"doc_module_name":9,"category_name":27,"show_sort_weight":11,"slug":28},41,"Investigación e Informes","research-report",{"id":30,"doc_module":4,"doc_module_name":9,"category_name":31,"show_sort_weight":11,"slug":32},37,"Literatura","literature",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":11,"slug":36},22,"Relatos y Novelas","story-novel",{"id":38,"doc_module":4,"doc_module_name":9,"category_name":39,"show_sort_weight":11,"slug":40},42,"Religión y Espiritualidad","religion-spirituality",{"id":42,"doc_module":4,"doc_module_name":9,"category_name":43,"show_sort_weight":11,"slug":44},40,"Salud y Atención Médica","healthcare",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":47,"show_sort_weight":11,"slug":48},24,"Tecnología","technology",{"code":4,"msg":50,"data":51},"ok",{"site_id":52,"language":53,"slug":54,"title":55,"keywords":56,"description":57,"schema_data":58,"social_meta":116,"head_meta":118,"extra_data":120,"updated_unix":122},110,"es","national-electrical-code-nec-table-310-16-and-table-310-17-permitted-current-carrying-capacity","Código Eléctrico Nacional (NEC) - Tabla 310-16 y Tabla 310-17 - Capacidad de corriente permitida","","Apéndice con tablas técnicas del Código Eléctrico Nacional (NEC) sobre la capacidad de corriente permitida de conductores y monoconductores con aislamiento de 0 a 2000 V. Incluye la Tabla 310-16 para conductores con aislamiento en rangos de 60 °C, 75 °C y 90 °C, considerando hasta 3 conductores por bandeja, cable o entierro directo y temperatura ambiental de 30 °C. Presenta la Tabla 310-17 para monoconductores al aire libre y define notas, incluyendo límites de protección sobrecorriente para calibres con asterisco (*), además de factores de corrección para temperaturas ambientales distintas de 30 °C y para más de tres conductores en una bandeja o cable.",{"@graph":59,"@context":115},[60,77,98],{"@type":61,"itemListElement":62},"BreadcrumbList",[63,68,71,74],{"item":64,"name":65,"@type":66,"position":67},"https://docshare.wps.com","Home","ListItem",1,{"item":69,"name":9,"@type":66,"position":70},"https://docshare.wps.com/es/document/",2,{"item":72,"name":27,"@type":66,"position":73},"https://docshare.wps.com/es/document/investigación-e-informes/",3,{"item":75,"name":55,"@type":66,"position":76},"https://docshare.wps.com/es/document/national-electrical-code-nec-table-310-16-and-table-310-17-permitted-current-carrying-capacity/366479/",4,{"url":75,"name":55,"@type":78,"image":79,"author":84,"headline":55,"publisher":87,"fileFormat":90,"inLanguage":53,"description":57,"dateModified":91,"datePublished":92,"encodingFormat":90,"isAccessibleForFree":93,"interactionStatistic":94},"DigitalDocument",{"url":80,"@type":81,"width":82,"height":83},"https://docshare.wps.com/thumbnails/national-electrical-code-nec-table-310-16-and-table-310-17-permitted-current-carrying-capacity/366479.png","ImageObject",300,407,{"name":85,"@type":86},"Connor ","Person",{"url":64,"name":88,"@type":89},"DocShare","Organization","application/pdf","2026-11-13","2026-09-23",true,{"@type":95,"interactionType":96,"userInteractionCount":76},"InteractionCounter",{"@type":97},"ViewAction",{"@type":99,"mainEntity":100},"FAQPage",[101,107,111],{"name":102,"@type":103,"acceptedAnswer":104},"¿Qué establece la Tabla 310-16 del NEC sobre la capacidad de corriente?","Question",{"text":105,"@type":106},"Define la capacidad de corriente permitida (en amperes) para conductores con aislamiento de 0 a 2000 V en rangos de temperatura del conductor, considerando hasta 3 conductores por bandeja, cable o entierro directo con temperatura ambiental de 30 °C.","Answer",{"name":108,"@type":103,"acceptedAnswer":109},"¿Qué describe la Tabla 310-17 del NEC?",{"text":110,"@type":106},"Establece la capacidad de corriente permitida para monoconductores con aislamiento de 0 a 2000 V al aire libre, usando como base una temperatura ambiental de 30 °C.",{"name":112,"@type":103,"acceptedAnswer":113},"¿Cómo se aplican los factores de corrección para temperaturas ambientales y más de tres conductores?",{"text":114,"@type":106},"Se utilizan factores según el rango de temperatura ambiente distinto a 30 °C y según el número de conductores que llevan corriente en una bandeja o cable, como indica la tabla de factores de corrección.","https://schema.org",{"og:url":75,"og:type":117,"og:title":55,"og:site_name":88,"og:description":57},"article",{"robots":119,"canonical":75},"index,follow",{"doc_id":121,"site_id":52},366479,1792396199,{"code":4,"msg":5,"data":124},{"doc_id":121,"user_id":125,"nickname":85,"user_avatar":126,"doc_module":4,"category_id":26,"category_name":27,"doc_title":55,"doc_description":57,"doc_content":127,"file_id":128,"file_url":129,"file_type":130,"file_size":131,"view_count":76,"is_deleted":4,"is_public":67,"is_downloadable":67,"audit_status":67,"page_count":67,"language":132,"language_code":53,"site_id":52,"html_lang":53,"table_of_contents":133,"faqs":134,"seo_title":135,"seo_description":57,"update_tm":136,"read_time":70,"preview_page_count":4},687207022233,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Apéndice  \nTablas técnicas  \nT6: Capacidad de corriente permitida de los conductores  \nn Código Eléctrico Nacional (NEC)  \nTabla 310-16  \nCapacidad de corriente (en Amperes) permitida de conductores conaislamiento de 0-2000V, 60° a 90°C (140° a 194°F); no más de 3 conductores en una bandeja, cable o en entierro directo, en base a una temperatura ambiental de 30°C (86°F)  \nTabla 310-17  \nCapacidad de corriente (en Amperes) permitida de monoconductores conaislamiento de 0-2000V, al aire libre, en base a una temperatura ambiental de 30°C (86°F)  \n\n| Tamaño del\u003Cbr>conductor AWG o\u003Cbr>KCMIL (MCM) | Rango de temperatura del conductor |  |  |\n| --- | --- | --- | --- |\n|  | 60°C\u003Cbr>(140°F) | 75°C\u003Cbr>(167°F) | 90°C\u003Cbr>(194°F) |\n| 18 | - | - | 14 |\n| 16 | - | - | 18 |\n| 14 | 20* | 20* | 25* |\n| 12 | 25* | 25* | 30* |\n| 10 | 30 | 35* | 40* |\n| 8 | 40 | 50 | 55 |\n| 6 | 55 | 65 | 75 |\n| 4 | 70 | 85 | 95 |\n| 3 | 85 | 100 | 110 |\n| 2 | 95 | 115 | 130 |\n| 1 | 110 | 130 | 150 |\n| 1/0 | 125 | 150 | 170 |\n| 2/0 | 145 | 175 | 195 |\n| 3/0 | 165 | 200 | 225 |\n| 4/0 | 195 | 230 | 260 |\n| 250 | 215 | 255 | 290 |\n| 300 | 240 | 285 | 320 |\n| 350 | 260 | 310 | 350 |\n| 400 | 280 | 355 | 380 |\n| 500 | 320 | 380 | 430 |\n| 600 | 355 | 420 | 475 |\n\n\n| Tamaño del\u003Cbr>conductor AWG o\u003Cbr>KCMIL (MCM) | Rango de temperatura del conductor |  |  |\n| --- | --- | --- | --- |\n|  | 60°C\u003Cbr>(140°F) | 75°C\u003Cbr>(167°F) | 90°C\u003Cbr>(194°F) |\n| 18 | - | - | 18 |\n| 16 | - | - | 24 |\n| 14 | 25* | 30* | 35* |\n| 12 | 30* | 35* | 40* |\n| 10 | 40* | 50* | 55* |\n| 8 | 60 | 70 | 80 |\n| 6 | 80 | 95 | 105 |\n| 4 | 105 | 125 | 140 |\n| 3 | 120 | 145 | 165 |\n| 2 | 140 | 170 | 190 |\n| 1 | 165 | 195 | 220 |\n| 1/0 | 195 | 230 | 260 |\n| 2/0 | 225 | 265 | 300 |\n| 3/0 | 260 | 310 | 350 |\n| 4/0 | 300 | 360 | 405 |\n| 250 | 340 | 405 | 455 |\n| 300 | 375 | 445 | 505 |\n| 350 | 420 | 505 | 570 |\n| 400 | 455 | 545 | 615 |\n| 500 | 515 | 620 | 700 |\n| 600 | 575 | 690 | 780 |\n\n* Nota: A menos que se permita específicamente en otra parte de este Código, la protección de sobrecorriente para los tipos de cable marcados con (*) no deberá exceder 15 amperios para el calibre 14 AWG, 20 amperios para 12 AWG y 30 amperios para 10 AWG, después de haber aplicado cualquier factor de corrección para la temperatura ambiente y el número de conductores.  \n\n| Factores de corrección para temperaturas ambiente diferentes a 30°C |  |  |  | Factores de corrección para más de tres conductores que llevan corriente en una bandeja o cable |  |\n| --- | --- | --- | --- | --- | --- |\n| Temp. ambiente\u003Cbr>en °C | 60°C | 75°C | 90°C | Número de conductoresque llevan corriente | Factor de corrección |\n| 21-25 | 1.08 | 1.05 | 1.04 | 4 hasta 6 | 0.80 |\n| 26-30 | 1.00 | 1.00 | 1.00 | 7 hasta 9 | 0.70 |\n| 31-35 | 0.91 | 0.94 | 0.96 | 10 hasta 20 | 0.50 |\n| 36-40 | 0.82 | 0.88 | 0.91 | 21 hasta 30 | 0.45 |\n| 41-45 | 0.71 | 0.82 | 0.87 | 31 hasta 40 | 0.40 |\n| 46-50 | 0.58 | 0.75 | 0.82 | 41 y más | 0.35 |\n| 51-55 | 0.41 | 0.67 | 0.76 |  |  |\n| 56-60 | - | 0.58 | 0.71 |  |  |\n| 61-70 | - | 0.33 | 0.58 |  |  |\n| 71-80 | - | - | 0.41 |  |  |\n\n[www.lappmexico.com](www.lappmexico.com) • 01800-024-5277 219","cbCaicUjNSva2pB4","https://ap.wps.com/l/cbCaicUjNSva2pB4","pdf",95388,"Spanish","# Apéndice\n## Tablas técnicas\n## Tabla 310-16\n## Tabla 310-17\n## Nota sobre calibres con (*)\n## Factores de corrección para temperaturas ambientales y más de tres conductores","[{\"question\":\"¿Qué establece la Tabla 310-16 del NEC sobre la capacidad de corriente?\",\"answer\":\"Define la capacidad de corriente permitida (en amperes) para conductores con aislamiento de 0 a 2000 V en rangos de temperatura del conductor, considerando hasta 3 conductores por bandeja, cable o entierro directo con temperatura ambiental de 30 °C.\"},{\"question\":\"¿Qué describe la Tabla 310-17 del NEC?\",\"answer\":\"Establece la capacidad de corriente permitida para monoconductores con aislamiento de 0 a 2000 V al aire libre, usando como base una temperatura ambiental de 30 °C.\"},{\"question\":\"¿Cómo se aplican los factores de corrección para temperaturas ambientales y más de tres conductores?\",\"answer\":\"Se utilizan factores según el rango de temperatura ambiente distinto a 30 °C y según el número de conductores que llevan corriente en una bandeja o cable, como indica la tabla de factores de corrección.\"}]","Código Eléctrico Nacional (NEC) - Tabla 310-16 y Tabla 310-17 - Capacidad de corriente permitida | PDF",1790165730]