[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-es-110":3,"doc-seo-367789-110":49,"doc-detail-367789-es":124},{"code":4,"msg":5,"data":6},0,"success",[7,13,17,21,25,29,33,37,41,45],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},39,"Document","Cómic",60,"comic",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":11,"slug":16},43,"Estilo de Vida","lifestyle",{"id":18,"doc_module":4,"doc_module_name":9,"category_name":19,"show_sort_weight":11,"slug":20},38,"Examen","exam",{"id":22,"doc_module":4,"doc_module_name":9,"category_name":23,"show_sort_weight":11,"slug":24},44,"General","general",{"id":26,"doc_module":4,"doc_module_name":9,"category_name":27,"show_sort_weight":11,"slug":28},41,"Investigación e Informes","research-report",{"id":30,"doc_module":4,"doc_module_name":9,"category_name":31,"show_sort_weight":11,"slug":32},37,"Literatura","literature",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":11,"slug":36},22,"Relatos y Novelas","story-novel",{"id":38,"doc_module":4,"doc_module_name":9,"category_name":39,"show_sort_weight":11,"slug":40},42,"Religión y Espiritualidad","religion-spirituality",{"id":42,"doc_module":4,"doc_module_name":9,"category_name":43,"show_sort_weight":11,"slug":44},40,"Salud y Atención Médica","healthcare",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":47,"show_sort_weight":11,"slug":48},24,"Tecnología","technology",{"code":4,"msg":50,"data":51},"ok",{"site_id":52,"language":53,"slug":54,"title":55,"keywords":56,"description":57,"schema_data":58,"social_meta":117,"head_meta":119,"extra_data":121,"updated_unix":123},110,"es","budget-electrical-installations-low-voltage-system-05","Presupuesto - Instalaciones Eléctricas - Sistema de Baja Tensión - 05","","Presupuesto de instalaciones eléctricas para el proyecto de mejoramiento de los servicios de salud y bienestar de la gerencia de desarrollo humano de San Isidro (Lima, Lima, distrito de San Isidro), con costo referencial al 18/06/2021. El contenido organiza partidas por sistema de baja tensión, incluyendo salidas para alumbrado, salidas para interruptores, salidas para tomacorrientes con configuraciones por altura y uso (incluye tomas de comunicaciones y control de acceso/nivel), y salidas de fuerza para equipos eléctricos como ventiladores, extractores, unidades condensadoras, equipos de presurización y bombas.",{"@graph":59,"@context":116},[60,77,99],{"@type":61,"itemListElement":62},"BreadcrumbList",[63,68,71,74],{"item":64,"name":65,"@type":66,"position":67},"https://docshare.wps.com","Home","ListItem",1,{"item":69,"name":9,"@type":66,"position":70},"https://docshare.wps.com/es/document/",2,{"item":72,"name":27,"@type":66,"position":73},"https://docshare.wps.com/es/document/investigación-e-informes/",3,{"item":75,"name":55,"@type":66,"position":76},"https://docshare.wps.com/es/document/budget-electrical-installations-low-voltage-system-05/367789/",4,{"url":75,"name":55,"@type":78,"image":79,"author":84,"headline":55,"publisher":87,"fileFormat":90,"inLanguage":53,"description":57,"dateModified":91,"datePublished":92,"encodingFormat":90,"isAccessibleForFree":93,"interactionStatistic":94},"DigitalDocument",{"url":80,"@type":81,"width":82,"height":83},"https://docshare.wps.com/thumbnails/budget-electrical-installations-low-voltage-system-05/367789.png","ImageObject",300,407,{"name":85,"@type":86},"mieayamfan","Person",{"url":64,"name":88,"@type":89},"DocShare","Organization","application/pdf","2026-10-07","2026-09-23",true,{"@type":95,"interactionType":96,"userInteractionCount":98},"InteractionCounter",{"@type":97},"ViewAction",6,{"@type":100,"mainEntity":101},"FAQPage",[102,108,112],{"name":103,"@type":104,"acceptedAnswer":105},"Cuál es la fecha de referencia del costo en el presupuesto?","Question",{"text":106,"@type":107},"El costo al 18/06/2021 figura en el apartado de municipalidad y ubicación del presupuesto.","Answer",{"name":109,"@type":104,"acceptedAnswer":110},"Qué incluye el apartado de sistema de baja tensión?",{"text":111,"@type":107},"Incluye salidas para alumbrado, salidas para interruptores, salidas para tomacorrientes y salidas de fuerza para distintos equipos.",{"name":113,"@type":104,"acceptedAnswer":114},"Cómo se describen las salidas para tomacorrientes dentro de la partida?",{"text":115,"@type":107},"Se listan por tipo y ubicación (muro, mueble, piso) y con especificaciones como alturas (h=0.3m, h=1.2m, etc.), además de variantes para comunicaciones, agua y control de acceso o nivel.","https://schema.org",{"og:url":75,"og:type":118,"og:title":55,"og:site_name":88,"og:description":57},"article",{"robots":120,"canonical":75},"index,follow",{"doc_id":122,"site_id":52},367789,1790671861,{"code":4,"msg":5,"data":125},{"doc_id":122,"user_id":126,"nickname":85,"user_avatar":127,"doc_module":4,"category_id":26,"category_name":27,"doc_title":55,"doc_description":57,"doc_content":128,"file_id":129,"file_url":130,"file_type":131,"file_size":132,"view_count":98,"is_deleted":4,"is_public":67,"is_downloadable":67,"audit_status":67,"page_count":133,"language":134,"language_code":53,"site_id":52,"html_lang":53,"table_of_contents":135,"faqs":136,"seo_title":137,"seo_description":57,"update_tm":138,"read_time":139},962090893677,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Presupuesto  \nPresupuesto  \nSubpresupuesto Cliente  \nLugar  \nItem  \n0102006 \"MEJORAMIENTO DE LOS SERVICIOS DE SALUD Y BIENESTAR DE LA GERENCIA DE DESARROLLO HUMANO DE SAN  \nISIDRO, DISTRITO DE SAN ISIDRO, PROVINCIA DE LIMA, DEPARTAMENTO DE LIMA\"  \n005 INSTALACIONES ELÉCTRICAS  \nMUNICIPALIDAD DISTRITAL DE SAN ISIDRO Costo al 18/06/2021  \nLIMA-LIMA-SAN ISIDRO  \nDescripción Und. Metrado Precio S/. Parcial S/.  \n05  \n05.01  \n05.01.01  \n[05.01.01.01](05.01.01.01)  \n05.01.01.01.01  \n05.01.01.01.02  \n05.01.01.01.03  \n05.01.01.01.04  \n05.01.01.01.05  \n05.01.01.01.06  \n05.01.01.01.07  \n05.01.01.01.08  \n[05.01.01.02](05.01.01.02)  \nINSTALACIONES ELECTRICAS  \nSISTEMA DE BAJA TENSIÓN  \nSALIDAS PARA ALUMBRADO, TOMACORRIENTES, FUERZAY SEÑALES DÉBILESSALIDAS PARA ALUMBRADO  \nSALIDA PARA ALUMBRADO ENTECHO (EMT)  \nSALIDA PARA ALUMBRADO DE EMEREGNCIA EN PARED (EMT)  \nSALIDA PARA ALUMBRADOADOSADA ENTECHO (EMT)  \nSALIDA PARA ALUMBRADO DE SEÑALÉTICA (EMT)  \nSALIDA PARA ALUMBRADO EN PARED (EMT)  \nSALIDA PARA ALUMBRADO EN PISO (EMT)  \nSALIDA PARA POSTE (EMT)  \nSALIDA PARA ILUMINACIÓN DE LOGOTIPOS (EMT)  \nSALIDAS PARA INTERRUPTORES  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \n138.00  \n96.00 382.00  \n33.00 44.00  \n6.00 3.00  \n2.00  \n81.58 99.35  \n81.58 99.35  \n99.35 81.58  \n99.35 99.35  \n1,182,128.57  \n1,182,128.57  \n254,258.28  \n60,595.38  \n11,258.04  \n9,537.60  \n31,163.56  \n3,278.55  \n4,371.40  \n489.48 298.05  \n198.70  \n59,105.13  \n05.01.01.02.01  \n05.01.01.02.02  \n05.01.01.02.03  \n05.01.01.02.04  \n05.01.01.02.05  \n05.01.01.02.06  \n05.01.01.02.07  \n[05.01.01.03](05.01.01.03)  \nSALIDA PARA INTERRUPTOR UNIPOLAR SIMPLE 10A, 220V (EMT)  \nSALIDA PARA INTERRUPTOR UNIPOLAR DOBLE 10A, 220V (EMT)  \nSALIDA PARA INTERRUPTOR UNIPOLAR TRIPLE 10A, 220V (EMT)  \nSALIDA PARA INTERRUPTOR UNIPOLAR DE CONMUTACIÓN SIMPLE 10A, 220V (EMT)  \nSALIDA PARA INTERRUPTOR UNIPOLAR DE CONMUTACIÓN DOBLE 10A, 220V (EMT)  \nSENSOR DE OCUPACIÓN / MOVIMIENTO (EMT)  \nSENSOR DE LUMINOSIDAD (EMT)  \nSALIDAS PARA TOMACORRIENTE  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \n187.00 5.00  \n3.00 20.00  \n4.00  \n156.00  \n14.00  \n103.69 108.69  \n112.69 108.19  \n114.94  \n214.69 194.17  \n19,390.03  \n543.45  \n338.07 2,163.80  \n459.76  \n33,491.64  \n2,718.38  \n52,908.76  \n05.01.01.03.01 SALIDA PARA TOMACORRIENTE DOBLE EN MURO (EMT) h=0. 3m  \n05.01.01.03.02 SALIDA PARA TOMACORRIENTE DOBLE EN MURO (EMT) h=1 . 2m  \n05.01.01.03.03 SALIDA PARA TOMACORRIENTE DOBLE EN MUEBLE  \n05.01.01.03.04 SALIDA PARA TOMACORRIENTE DOBLE C/TAPAA PRUEBA DE AGUA (EMT), h=0. 30m  \n05.01.01.03.05 SALIDA PARA TOMACORRIENTE DOBLE C/TAPAA PRUEBA DE AGUA (EMT), h=1 . 20m  \n05.01.01.03.06 SALIDA PARA TOMACORRIENTE DOBLE C/TAPAA PRUEBA DE AGUA (EMT), EN PISO  \n05.01.01.03.07 SALIDA PARA TOMACORRIENTE DOBLE EN MURO (EMT) h=2. 2m  \n05.01.01.03.08 SALIDA PARA TOMACORRIENTE DOBLE EN MURO (EMT) COMPUTOY  \nCOMUNICACIONES, h=0. 3m  \n05.01.01.03.09 SALIDA PARA TOMACORRIENTE DOBLE EN MURO (EMT) COMPUTOY  \nCOMUNICACIONES, h=1 . 2m  \n05.01.01.03.10 SALIDA PARA TOMACORRIENTE DOBLE EN MUEBLE (COMPUTOY COMUNICACIONES)  \n05.01.01.03.11 SALIDA PARA TOMACORRIENTE DOBLE EN PISO (EMT), COMPUTOY  \nCOMUNICACIONES  \n05.01.01.03.12 SALIDA ESTABILIZADA PARA CONTROL DE ACCESO  \n05.01.01.03.13 SALIDA PARA CONTROL DE NIVEL EN CISTERNAS  \n05.01.01.03.14 SALIDA PARA CONTROL DE NIVEL DE BOMBA SUMERGIBLE  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \npto  \n179.00 17.00  \n2.00 1.00  \n1.00  \n17.00  \n1.00 93.00  \n2.00  \n4.00  \n2.00  \n3.00 3.00  \n1.00  \n157.51 157.51  \n159.38 229.01  \n229.01  \n229.01  \n157.51 157.51  \n195.56  \n159.38  \n160.81  \n157.27 184.71  \n184.71  \n28,194.29  \n2,677.67  \n318.76 229.01  \n229.01  \n3,893.17  \n157.51 14,648.43  \n391.12  \n637.52  \n321.62  \n471.81 554.13  \n184.71  \n[05.01.01.04](05.01.01.04)  \n05.01.01.04.01  \n05.01.01.04.02  \n05.01.01.04.03  \n05.01.01.04.04  \n05.01.01.04.05  \nSALIDAS DE FUERZA  \nSALIDA DE FUERZA PARA EXTRACTOR FLUJO MIXTO-EFM-S1-01-15HP/380V/3 SALIDA DE FUERZA PARA VENTILADOR CENTRÍFUG","cbCaibwGb1HcpBJt","https://ap.wps.com/l/cbCaibwGb1HcpBJt","pdf",33852,5,"Spanish","# Presupuesto\n## Subpresupuesto Cliente\n## Instalaciones eléctricas\n### Sistema de baja tensión\n### Salidas para alumbrado\n### Salidas para interruptores\n### Salidas para tomacorrientes\n### Salidas de fuerza","[{\"question\":\"Cuál es la fecha de referencia del costo en el presupuesto?\",\"answer\":\"El costo al 18/06/2021 figura en el apartado de municipalidad y ubicación del presupuesto.\"},{\"question\":\"Qué incluye el apartado de sistema de baja tensión?\",\"answer\":\"Incluye salidas para alumbrado, salidas para interruptores, salidas para tomacorrientes y salidas de fuerza para distintos equipos.\"},{\"question\":\"Cómo se describen las salidas para tomacorrientes dentro de la partida?\",\"answer\":\"Se listan por tipo y ubicación (muro, mueble, piso) y con especificaciones como alturas (h=0.3m, h=1.2m, etc.), además de variantes para comunicaciones, agua y control de acceso o nivel.\"}]","Presupuesto - Instalaciones Eléctricas - Sistema de Baja Tensión - 05 | PDF",1790172636,8]